(7) Any other equipment requiring extremely high levels of safety
and/or reliability equal to the equipment listed above
*Notes:
1. There is a possibility that our products can be used only
for aviation equipment that does not directly affect the safe
operation of aircraft (e.g., in-flight entertainment, cabin
light, electric seat, cooking equipment) if such use meets
requirements specified separately by TAIYO YUDEN. Please
be sure to contact TAIYO YUDEN for further information
before using our products for such aviation equipment.
2. Implantable medical devices contain not only internal unit
which is implanted in a body, but also external unit which is
connected to the internal unit.
4. Limitation of Liability
Please note that unless you obtain prior written consent of TAIYO
YUDEN, TAIYO YUDEN shall not be in any way responsible for
any damages incurred by you or third parties arising from use of
the products listed in this catalog for any equipment that is not
intended for use by TAIYO YUDEN, or any equipment requiring
inquiry to TAIYO YUDEN or prohibited for use by TAIYO YUDEN
as described above.
■
Safety Design
When using our products for high safety and/or reliability-required
equipment or circuits, please fully perform safety and/or reliability
evaluation. In addition, please install (i) systems equipped with
a protection circuit and a protection device and/or (ii) systems
equipped with a redundant circuit or other system to prevent an
unsafe status in the event of a single fault for a failsafe design to
ensure safety.
■
Intellectual Property Rights
Information contained in this catalog is intended to convey examples
of typical performances and/or applications of our products and is
not intended to make any warranty with respect to the intellectual
property rights or any other related rights of TAIYO YUDEN or any
third parties nor grant any license under such rights.
■
Limited Warranty
Please note that the scope of warranty for our products is limited to
the delivered our products themselves and TAIYO YUDEN shall not
be in any way responsible for any damages resulting from a failure
or defect in our products. Notwithstanding the foregoing, if there is
a written agreement (e.g., supply and purchase agreement, quality
assurance agreement) signed by TAIYO YUDEN and your company,
TAIYO YUDEN will warrant our products in accordance with such
agreement.
■
TAIYO YUDEN’s Official Sales Channel
The contents of this catalog are applicable to our products which are
purchased from our sales offices or authorized distributors (hereinafter
“TAIYO
YUDEN’official sales channel” Please note that the contents
s
).
of this catalog are not applicable to our products purchased from any
seller other than TAIYO YUDEN’official sales channel.
s
■
Caution for Export
Some of our products listed in this catalog may require specific
procedures for export according to
“U.S.
Export Administration
,
“Foreign
Exchange and Foreign Trade Control Law”
Regulations”
of Japan, and other applicable regulations. Should you have any
questions on this matter, please contact our sales staff.
20
for High Quality Equipment
Industrial Application Guide
The products described as“For Telecommunications Infrastructure and Industrial Equipment”in this
catalog are intended for use in the equipment shown in the below table as its typical example. Therefore,
when using our products for these equipment, please check it carefully by referring to the part number
or the individual product specification sheets and use the corresponding products. Should you have any
questions on this matter, please contact us.
Category
Telecommunications
Infrastructure
Telecommunications Infrastructure and Industrial Equipment (Typical Example)
・Base Station
・Optical Transceiver
・Router/Switch (Carrier-Grade)
・UPS (Uninterruptible Power Supply), etc.
・PLC (Programmable Logic Controller)
・Servomotor/Servo Driver
・Industry Robot, etc.
・Gas Meter
Measurement
・Water Meter
APPLICATION GUIDE
INDUSTRIAL APPLICATION GUIDE
16
Factory Automation
・Flow Meter
・Pressure Gauge Meter
・Magnetometer
・
Thermometer, etc.
・Power Conditioner (Solar Power System)
・Smart Meter
・GFCI (Ground Fault Circuit Interrupter)
・Electric Vehicle Charging Station, etc.
Electric Power Apparatus
■
Part Numbering System
Multilayer Ceramic Capacitors:
8
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
⑯
⑰
If the 15th code from the left is“8” it indicates“For Telecommunications Infrastructure and Industrial
,
Equipment”or“For Medical Devices”
.
Inductors:
8
If the 1st code from the right is“8”regardless of the total digit number, it indicates“For
Telecommunications Infrastructure and Industrial Equipment”or“For Medical Devices”
.
Because there are some exceptions, for details please refer to each page of this catalog where the
part numbering system of each product is described.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .
20
for High Quality Equipment
Medical Application Guide
The products described as“For Medical Devices”in this catalog are intended for use in the medical
devices classified as GHTF Classes A to C (Japan Classes I to III) except for all medical devices classified
as GHTF Class D (Japan Class IV) and implantable medical devices (bone-anchored hearing aid, artificial
retina system, and external unit which is connected to internal unit which is implanted in a body, etc.).
Therefore, when using our products for these medical devices, please check it carefully by referring to the
part number or the individual product specification sheets and use the corresponding products. Should
you have any questions on this matter, please contact us.
APPLICATION GUIDE
Risk Level
Classification according to the PMD Act of Japan
(based on the GHTF Rules)
Low
General
Medical Devices
(GHTF Class A)
Medical devices with
extremely low risk to the
human body in case of
problems
[Ex.]
High
Class I
Controlled
Medical Devices
(GHTF Class B)
Medical devices with
relatively low risk to the
human body in case of
problems
[Ex.]
・Electronic Thermometer
・Electronic Blood Pressure
Class II
Specially-controlled
Medical Devices
(GHTF Class C)
Medical devices with
relatively high risk to the
human body in case of
problems
Class III
Specially-controlled
Medical Devices
(GHTF Class D)
Medical devices highly
invasive to patients and
with life-threatening risk in
case of problems
Class IV
MEDICAL APPLICATION GUIDE
Japan
・In Vitro Diagnostic Devices
・Nebulizer
・Blood Gas Analyzer
Gauge
・Plethysmographs
・Electronic Endoscope
・Breathing Sensor
・Hearing Aid
・
AC-powered Operating Table ・Electrocardiograph
・Surgical Light
・MRI
Defibrillator)
・Cholesterol Analysis Device ・Ultrasonic Diagnostic System ・Skin Laser Scanner
・Blood Type Analysis Device, ・
Diagnostic Imaging Equipment ・Electric Surgical Unit
・Glucose Monitoring System ・Inspection Device with
Cardiac Catheter
・AED (Automated External
・Defibrillator, etc.
FDA Classification
General Controls
Class I
General Controls and
Special Controls
Class II
General Controls and
Premarket Approval
Medical devices with the possibility
of causing serious injury, disability
Class III
U.S.A.
Medical devices without the possibility Medical devices with the possibility
of causing serious injury or harm
of causing injury or harm to the
to the patient or user even if there
is a defect or malfunction in such
medical devices
patient or user if there is a defect or
malfunction in such medical devices
or death to the patient or user if a
defect or malfunction occurs in such
medical devices
Coverage of
those Classes by
TAIYO YUDEN
Products
Product Series for Medical Devices
*Note: It is prohibited that our products are used in some medical devices such as
implantable medical devices even if such medical devices are classified as GHTF
Class C (Japan Class III).
N/A
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .
20
17
for High Quality Equipment
for High Quality Equipment
REFLOW
MULTILAYER CHIP BEAD INDUCTORS (BK SERIES)
MULTILAYER CHIP BEAD INDUCTORS (BK SERIES)
REFLOW
AEC-Q200
■PART
NUMBER
*Operating Temp. :
-55½125℃
B
K △
①
1
0
②
0
5
H
③
S
1
2 1
④
- T V
⑤ ⑥ ⑦
△=Blank space
①Series name
Code
BK△
②Dimensions(L×W)
Code
0603
1005
③Material
Code
HW
HS
HR
HM
LM
LL
TS
Series name
Multilayer chip bead inductor
Type(inch)
0603(0201)
1005(0402)
Dimensions
(L×W)[mm½
0.6×0.3
1.0×0.5
④Nominal impedance
Code
(example)
100
330
121
102
⑤Characteristics
Code
-
⑥Packaging
Code
T
⑦Internal code
Code
V
8
Nominal impedance[Ω
½
10
33
120
1000
MULTILAYER CHIP BEAD INDUCTORS (BK SERIES)
For Telecommunications Infrastructure and Industrial Equipment / Medical Devices
Characteristics
Standard
Material
Packaging
Taping
Refer to impedance curves
for material differences
Internal code
MLCI for Automotive
MLCI for Telecommunications infrastructure
and Industrial equipment / Medical devices
■FEATURES
●HW:For
broadband noise suppression.
●HS:For
broadband noise suppression.
●HR:For
upper 10MHz noise suppression.
●HM:For
upper 20MHz noise suppression.
●LM:For
high frequency noise suppression around 200MHz.
●LL:For
high frequency noise suppression from 100MHz.
●TS:Low
DC resistance HS version.
NOISE SUPPRESSION
COMPONENTS
■STANDARD
EXTERNAL DIMENSIONS / STANDARD QUANTITY
W
L
T
e
INDL
Type
BK 0603
(0201)
BK 1005
(0402)
L
0.60±0.03
(0.024±0.001)
1.00±0.05
(0.039±0.002)
W
0.30±0.03
(0.012±0.001)
0.50±0.05
(0.020±0.002)
T
030±0.03
(0.012±0.001)
0.50±0.05
(0.020±0.002)
e
0.15±0.05
(0.006±0.002)
0.25±0.10
(0.010±0.004)
Standard quantity [pcs]
Paper tape
Embossed tape
15000
10000
-
-
Unit:mm(inch)
hq_i_mlci_BK_e-E08R01
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .
20
141
for High Quality Equipment
■PART
NUMBER
・ All the Multilayer Chip Bead Inductors of the catalog lineup are RoHS compliant.
Notes)
・ The exchange of individual specifications is necessary depending on your application and/or circuit condition. Please contact TAIYO YUDEN's official sales channel.
・ The products are for Telecommunications infrastructure and Industrial equipment and for Medical devices.
Please consult with TAIYO YUDEN's official sales channel for the details of the product specifications, etc.,
and please review and approve the product specifications before ordering.
Please be sure to contact us for further information in advance when the products are used for automotive electronic equipment.
●BK
0603
Part number
Nominal impedance
[Ω½
22
33
80
120
240
600
Impedance tolerance
±25%
±25%
±25%
±25%
±25%
±25%
Measuring frequency
[MHz½
100
100
100
100
100
100
DC Resistance
[Ω½(max.)
0.065
0.070
0.18
0.23
0.32
0.75
Rated current
[mA½(max.)
500
500
500
450
400
270
Thickness
[mm½
0.30 ±0.03
0.30 ±0.03
0.30 ±0.03
0.30 ±0.03
0.30 ±0.03
0.30 ±0.03
Note
MULTILAYER CHIP BEAD INDUCTORS (BK SERIES)
INDL
142
For Telecommunications Infrastructure and Industrial Equipment / Medical Devices
BK
BK
BK
BK
BK
BK
0603HS220-T8
0603HS330-T8
0603TS800-T8
0603TS121-T8
0603TS241-T8
0603TS601-T8
●BK
1005
Part number
BK 1005HW680-T8
BK 1005HW121-T8
BK 1005HW241-T8
BK 1005HW431-T8
BK 1005HW601-T8
BK 1005HS100-T8
BK 1005HS330-T8
BK 1005HS680-T8
BK 1005HS800-T8
BK 1005HS121-T8
BK 1005HS241-T8
BK 1005HS431-T8
BK 1005HS601-T8
BK 1005HS102-T8
BK 1005HR601-T8
BK 1005HM750-T8
BK 1005HM121-T8
BK 1005HM241-T8
BK 1005HM471-T8
BK 1005HM601-T8
BK 1005HM102-T8
BK 1005LL100-T8
BK 1005LL220-T8
BK 1005LL330-T8
BK 1005LL470-T8
BK 1005LL680-T8
BK 1005LL121-T8
BK 1005LL181-T8
BK 1005LL241-T8
BK 1005LM182-T8
Nominal impedance
[Ω½
68
120
240
430
600
10
33
68
80
120
240
430
600
1000
600
75
120
240
470
600
1000
10
22
33
47
68
120
180
240
1800
Impedance tolerance
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
±25%
Measuring frequency
[MHz½
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
DC Resistance
[Ω½(max.)
0.17
0.24
0.31
0.50
0.60
0.03
0.06
0.10
0.10
0.20
0.30
0.45
0.55
0.58
0.60
0.18
0.18
0.30
0.45
0.50
0.70
0.11
0.18
0.25
0.33
0.31
0.45
0.50
0.70
0.90
Rated current
[mA½(max.)
500
450
400
350
300
1,000
700
700
700
500
400
350
300
300
300
350
300
300
250
250
150
500
400
400
350
400
350
300
250
120
Thickness
[mm½
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
0.50 ±0.05
Note
NOISE SUPPRESSION
COMPONENTS
※)The rated current is the value of current at which the temperature of the element is increased within 20℃.
hq_i_mlci_BK_INDL_e-E08R01
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .