POLYSNAP
®
POWER INLET MODULES
C14 IEC Fused Inlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Fused Inlet with 2.8mm or
6.3mm tags
Single Pole Switch Variations
Filtered Inlet Option
Options of I/O marked
switches
BZH01/Z0000/01
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
01
= PF0011/63
02
= PF0011/28
Twin Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
15
= PF0033/63
16
= PF0033/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical
Combination of Other Components
Single Pole Switch:
01
= S.P Switch
.
Single Pole Neon Switch:
Cxxxx = High Performance Standard
(Single Fuse Version only)
02
= S.P Red Neon Switch
.
08
= S.P Green Neon Switch
.
Neon Indicator:
03
= Red Neon Indicator
Single Pole High Inrush Switch:
46
= S.P High Inrush Switch
.
Single Pole Switch Marked I/O:
69
= S.P Switch (I/O)
.
Single Pole Neon Switch Marked (I/O):
71
= S.P Red Neon Switch (I/O)
.
74
= S.P Green Neon Switch (I/O)
.
Single Pole High Inrush Switch Marked (I/O):
98
= S.P High Inrush Switch (I/O)
.
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages
97-100.
E.g. BZH01/A0620/01
Note: For technical details of individual components please see page 74
www.bulgin.co.uk
87
IEC CONNECTORS
How to Order
BZH xx / xxxxx / xx
POLYSNAP
®
POWER INLET MODULES
C14 IEC Fused Inlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Fused Inlet with 2.8mm or
6.3mm tags
Double Pole Switch Variations
Filtered Inlet Option
Options of I/O marked
switches
BZH01/Z0000/10
IEC CONNECTORS
How to Order
BZH xx / xxxxx / xx
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
01
= PF0011/63
02
= PF0011/28
Twin Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
15
= PF0033/63
16
= PF0033/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical
Combination of Other Components
Neon Indicator:
03
= Red Neon Indicator
Double Pole Switch:
Cxxxx = High Performance Standard
(Single Fuse Version only)
10
= D.P Switch
.
Double Pole Neon Switch:
11
= D.P Red Neon Switch
.
12
= D.P Green Neon Switch
.
Double Pole High Inrush Switch:
13
= D.P High Inrush Switch
.
Double Pole Switch marked I/O:
70
= D.P Switch (I/O)
.
Double Pole Neon Switch Marked (I/O):
76
= D.P Red Neon Switch (I/O)
.
77
= D.P Green Neon Switch (I/O)
.
Double Pole High Inrush Switch Marked
(I/O):
78
= D.P High Inrush Switch (I/O)
.
B1
= D.P High Inrush Green Neon Switch
.
(I/O)
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages
97-100.
E.g. BZH01/A0620/10
Note: For technical details of individual components please see page 74
88
www.bulgin.co.uk
POLYSNAP
®
POWER INLET MODULES
C14 IEC Inlet/Sheet F IEC Outlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Inlet/Outlet Combination
with 2.8mm or 6.3mm tags
Shuttered or Non-Shuttered
Outlet
Single Pole Switch Variations
Filtered Inlet Option
BZH09/Z0000/01
Options of I/O marked
switches
Type of Inlet / Outlet
C14 Power Inlet (cold condition) and Sheet F
Non-shuttered Power Outlet, 2.8 or 6.3mm tabs:
09
= PX0575/63 + PX0695/63
10
= PX0575/28 + PX0695/28
C14 Power Inlet (cold condition) and Sheet F
Shuttered Power Outlet , 2.8 or 6.3mm tabs:
17
= PX0575/63 + PX0783/63
18
= PX0575/28 + PX0783/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical
Combination of Other Components
Single Pole Switch:
01
= S.P Switch
.
Single Pole Neon Switch:
02
= S.P Red Neon Switch
.
08
= S.P Green Neon Switch
.
Neon Indicator:
03
= Red Neon Indicator
Single Pole High Inrush Switch:
46
= S.P High Inrush Switch
.
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages 95-96.
E.g. BZH09/A0120/01
Single Pole Switch Marked I/O:
69
= S.P Switch (I/O)
.
Single Pole Neon Switch Marked (I/O):
71
= S.P Red Neon Switch (I/O)
.
74
= S.P Green Neon Switch (I/O)
.
Single Pole High Inrush Switch Marked
(I/O):
98
= S.P High Inrush Switch (I/O)
.
Note: For technical details of individual components please see page 74
www.bulgin.co.uk
89
IEC CONNECTORS
How to Order
BZH xx / xxxxx / xx
POLYSNAP
®
POWER INLET MODULES
C14 IEC Inlet/Sheet F IEC Outlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Inlet/Outlet Combination
with 2.8mm or 6.3mm tags
Single or Twin Fused Inlet
Shuttered or Non-Shuttered
Outlet
Double Pole Switch Variations
BZH11/Z0000/10
Filtered Inlet Option
Options of I/O marked
switches
IEC CONNECTORS
How to Order
BZH xx / xxxxx / xx
Type of Inlet/Outlet
Single Fused C14 Power Inlet (cold condition) and
Sheet F Power Outlet, 2.8 or 6.3mm tabs:
11
= PF0011/63 + PX0695/63
12
= PF0011/28 + PX0695/28
Twin Fused C14 Power Inlet (cold condition)
and Sheet F Power Outlet , 2.8 or 6.3mm tabs:
13
= PF0033/63 + PX0695/63
14
= PF0033/28 + PX0695/28
Single Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs:
19
= PF0011/63 + PX0783/63
20
= PF0011/28 + PX0783/28
Twin Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs:
21
= PF0033/63 + PX0783/63
22
= PF0033/28 + PX0783/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical
Combination of Other Components
Neon Indicator:
D3
= Red Neon Indicator
Double Pole Switch:
Cxxxx = High Performance Standard
10
= D.P Switch
.
Double Pole Neon Switch:
11
= D.P Red Neon Switch
.
12
= D.P Green Neon Switch
.
Double Pole High Inrush Switch:
13
= D.P High Inrush Switch
.
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages
97-100.
E.g. BZH11/A0620/10
Double Pole Switch Marked I/O:
70
= D.P Switch (I/O)
.
Double Pole Neon Switch Marked (I/O):
76
= D.P Red Neon Switch (I/O)
.
77
= D.P Green Neon Switch (I/O)
.
Double Pole High Inrush Switch Marked
(I/O):
78
= D.P High Inrush Switch (I/O)
.
B1
= D.P High Inrush Green Neon Switch
.
(I/O)
Note: For technical details of individual components please see page 74
90
www.bulgin.co.uk
POLYSNAP
®
POWER INLET MODULES
C14 IEC Fused Inlet/Sheet F IEC Outlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Fused Inlet/Outlet
Combination with 2.8mm or
6.3mm tags
Filtered Inlet Option
Single or Twin Fused
BZH11/Z0000/00
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition) and
Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm
tabs:
11
= PF0011/63 + PX0695/63
12
= PF0011/28 + PX0695/28
Twin Fused C14 Power Inlet (cold condition) and
Sheet F Non-shuttered Power Outlet , 2.8 or 6.3mm
tabs:
13
= PF0033/63 + PX0695/63
14
= PF0033/28 + PX0695/28
Single Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs:
19
= PF0011/63 + PX0783/63
20
= PF0011/28 + PX0783/28
Twin Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet , 2.8 or 6.3mm
tabs:
21
= PF0033/63 + PX0783/63
22
= PF0033/28 + PX0783/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical
Cxxxx = High Performance Standard
(Single Fuse Version only)
Combination of Other Components
None
00
= None
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages
97-100.
E.g. BZH11/A0620/00
Note: For technical details of individual components please see page 74
www.bulgin.co.uk
91
IEC CONNECTORS
How to Order
BZH xx / xxxxx / xx