(Half-wave pulse of sine wave: 11ms; detection time: 10s)
Min. 10 M (at 500V DC,
Measurement at same
location as “Breakdown
voltage” section.)
20 A continuous
1 Form B type
1 Form B
Typ 3m (By voltage drop 6V DC 1A)
Max. 0.3 V
(by voltage drop
12 V DC 20 A)
Ag alloy (Cadmium free)
20 A 12 V DC
20 A continuous
1.8 W
Max. 0.4 V
(by voltage drop
12 V DC 20 A)
1 Form C type
1 Form C
Operate time (at 20C
68F)
Release time (at 20C
68F)
Shock
resistance
Mechanical
characteristics
Vibration
resistance
Functional
Destructive
Functional
Destructive
Min. 1,000 m/s
2
{100G} (Half-wave pulse of sine wave: 6ms)
Rubber bracket A type: 50 Hz to 500 Hz, Min. 100 m/s
2
{10G}
Screw-mounting and direct coupling type: 33 Hz, Min. 44.1 m/s
2
{4.5G} (Detection time: 10s)
Rubber bracket A type: 50 Hz to 500 Hz, Min. 100 m/s
2
{10G}
Screw-mounting and direct coupling type: 33 Hz, Min. 44.1 m/s
2
{4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 10
5
(operating frequency: 2s ON,
2s OFF) (1.4 W and 1.8 W type at 20 A)
Min. 2
10
4
(operating frequency: 3s
ON, 15s OFF) (1.8 W type at 30 A)
Min. 10
6
(at 120 cpm)
Min. 10
5
(operating frequency: 2s ON, 2s OFF)
Min. 5
10
5
(at 120 cpm)
Expected life
Electrical (at nominal switching capacity)
Mechanical
Conditions
Water-proof
standard
Mass
Conditions for operation, transport and
storage*
2
Max. operating speed
Water-proof standard
Ambient temperature: –30C to +80C
–22F to +176F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
15 cpm (1.4 W type: at nominal load,
1.8 W type: at 20 A)
15 cpm (at nominal switching capacity)
Sealed type: JIS D 0203 S2, Dust cover type: JIS D 0203 R2
Rubber bracket A type: 23 g
.81 oz,
Screw-mounting and direct coupling type: 19 g
.67 oz
31 g
1.09 oz
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in
AMBIENT ENVIRONMENT section in Relay Technical Information.
ds_61201_en_ca: 010113J
3
CA
2) 24 V DC type
Characteristics
Arrangement
Contact
Contact resistance (Initial)
Contact voltage drop
Contact material
Nominal switching capacity (resistive load)
(operating frequency: 2s ON, 2s OFF)
Rating
Max. carrying current
Nominal operating power
Min. switching capacity (resistive load)*
Insulation resistance (Initial)
Electrical
characteristics
Breakdown voltage
(Initial)
Between open contacts
Between contacts and coil
1
Item
1 Form C
Typ 3m (By voltage drop 6V DC 1A)
Specifications
1 Form C type
Max. 0.4 V (after electrical life test, by voltage drop 24 V DC 10 A)
Ag alloy (Cadmium free)
10 A 24V DC
10 A continuous (at coil applied voltage 28 V DC, 80C
176F)
1.8 W
1 A 14V DC
Min. 10 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
{10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
Min. 1,000 m/s
2
{100G} (Half-wave pulse of sine wave: 6ms)
33 Hz, Min. 44.1 m/s
2
{4.5G} (Detection time: 10s)
33 Hz, Min. 44.1 m/s
2
{4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 10
5
(operating frequency: 2s ON, 2s OFF)
Min. 5
10
5
(at 120 cpm)
Ambient temperature: –30C to +80C
–22F to +176F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
15 cpm (nominal switching capacity)
JIS D 0203 S2
31 g
1.09 oz
Operate time (at nominal voltage) (at 20C
68F)
Release time (at nominal voltage) (at 20C
68F)
Shock resistance
Mechanical
characteristics
Vibration resistance
Functional
Destructive
Functional
Destructive
Expected life
Electrical (at nominal switching capacity)
Mechanical
Conditions for operation, transport and storage*
2
Max. operating speed
Conditions
Water-proof
standard
Mass
Water-proof standard
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in
AMBIENT ENVIRONMENT section in Relay Technical Information.