Thru Hole Mount VC-TCXO
• 4.5 mm height
• Tight stability available
• TTL/HCMOS output
CARDINAL COMPONENTS
Series CC123
Part Numbering Example: CC123 L - A1 B2 45 - 22.5792 M
CC123
SERIES
CC123
L
A1
B2
STABILITY
B1 = ±5.0 ppm
B2 = ±3.0 ppm
B3 = ±2.5 ppm
B4 = ±2.0 ppm
B5 = ±1.5 ppm
B9 = ±4.0 ppm
BB = ±4.5 ppm
BF = ±3.5 ppm
45
SYMMETRY
Blank = 40/60%
45 = 45/55%
22.5792
FREQUENCY
M
PULL RANGE
L = ±10 ppm
M = ±5 ppm
VOLTAGE
OPERATING TEMP.
Blank = 5V A2 = -10°C ~+60°C
A3 = -30°C ~+75°C
L = 3.3V
A5 = -20°C ~+70°C
A9 = 0°C ~+50°C
AA = -10°C ~+70°C
AB = -30°C ~+70°C
AC = -30°C ~+60°C
AE = -40°C ~+80°C
Specifications:
Frequency Range:
1.000 MHz to 35.000 MHz
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
+3.0 VDC ±5%
CC123
Available Stability Options:
±1.5
±2.0
±2.5
±3.0
±3.5
±4.0
±4.5
±5.0
Output Series:
Input Voltage:
Operating Temperature
Range Options:
TTL/CMOS
+5.0 VDC ±5%,
0°C to +50°C
-10°C to +60°C
-10°C to +70°C
-20°C to +70°C
-30°C to +60°C
-30°C to +70°C
-30°C to +75°C
-40°C to +80°C
±5 ppm Min.
±10 ppm Min.
+2.5 VDC, ± 2.0 VDC,
TTL V
OL
=0.4 V Max.
TTL V
OH
=2.4 V Min.
HCMOS V
OL
=10%V
DD
V Max.
HCMOS V
OH
=90%V
DD
V Min.
±3.0 ppm Minimum
+1.65 VDC, ± 1.35VDC
Frequency Tuning Range:
External Control Voltage:
Output Voltage:
Frequency Trim Range
With Externally
Adjustable Trimmer:
Output Load:
Maximum Input Current:
Maximum Rise/Fall Time:
Duty Cycle:
Maximum Frequency
Aging at +25°C:
Storage Temperature:
10 LS TTL, 15 pf CMOS
20 mA
10 ns
40/60%
±1 ppm/yr
-40°C to +80°C
155 Route 46 West
Wayne, NJ 07470
Rev:
VT-090414-13
Cardinal Components, Inc.
VT-1
TEL:
(973)785-1333
E-MAIL: sales@cardinalxtal.com
WEB: http://www.cardinalxtal.com