• Standard dimension fuses with 10kA minimum interrupting
rating.
10
5
1
One-Time CSA Type “P”
Volts
250V
Cat. No.
PON
Amp Ratings
15, 20, 25, 30,
35, 40, 45, 50, 60
(CSA “P”)
Ctn. Qty.
10
A
Catalog Number
and Volts
CDN
PON
250 VAC
Overall
Inches
(mm)
2.0
(50.8)
3.0
(76.2)
5.88
(149.4)
7.3
(185.4)
8.63
(219.2)
10.38
(263.7)
5.0
(127.0)
5.5
(139.7)
7.88
(200.2)
9.63
(244.6)
11.63
(295.4)
13.38
(339.9)
CDS
600V
Amps
1-30
35-60
70-100
110-200
225-400
450-600
1-30
35-60
70-100
110-200
225-400
450-600
B
Max.
Diameter
Inches
(mm)
.56
(14.3)
.81
(20.6)
—
—
—
—
—
—
—
—
.81
(20.6)
1.06
(27.0)
1.16
(29.46)
1.66
(42.16)
2.38
(60.45)
2.88
(73.15)
C
Min.
Blade Length
Inches
(mm)
—
—
—
—
1.0
(25.4)
1.38
(34.9)
1.88
(47.6)
2.25
(57.2)
—
—
—
—
—
—
—
—
—
—
—
—
D
Min.
Barrel Length
Inches
(mm)
—
—
—
—
—
—
4.13
(104.8)
4.63
(117.5)
5.19
(131.8)
—
—
—
—
—
—
—
—
—
—
—
—
E
Blade
Thickness
Inches
(mm)
—
—
—
—
.13
(3.2)
.19
(4.8)
.25
(6.4)
.25
(6.4)
—
—
—
—
.13
(3.2)
.19
(4.8)
.25
(6.4)
.25
(6.4)
F
Blade
Width
Inches
(mm)
—
—
—
—
.75
(19.1)
1.13
(28.6)
1.63
(41.3)
2
(50.8)
—
—
—
—
.75
(19.1)
1.13
(28.6)
1.63
(41.3)
2
(50.8)
12-17-98
SB98107
Rev. A
Form No. CDN, CDS, and PON
Page 1 of 3
BIF Doc #4126
Bussmann
®
Type “P” and “D” Fuses
Standard Code Fuses
Average Time/Current Curves
Cat. No. CDN 250VAC
AMPERE
RATING
CDN/CDS
PON
Average Time/Current Curves
Cat. No. CDS 600VAC
AMPERE
RATING
100
200
400
600
100
200
400
1,000
300
100
100
10
10
TIME IN SECONDS
TIME IN SECONDS
1
1
.1
.1
.01
100
1,000
10
10,000
40,000
.01
10,000
1,000
10
100
CURRENT IN AMPERES
CURRENT IN AMPERES
600
10
15
30
60
10
15
30
60
12-17-98
SB98107
Rev. A
Form No. CDN, CDS, and PON
Page 2 of 3
BIF Doc #4126
Bussmann
®
Type “P” and “D” Fuses
Standard Code Fuses
Average Time/Current Curves
Cat. No. PON 250VAC
15A
30A
60A
AMPERE
RATING
CDN/CDS
PON
100
10
TIME IN SECONDS
1
.1
20
RMS SYMMETRICAL CURRENT IN AMPERES
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin
is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.