Rectifiers, General Purpose
(Continued)
IO (AMPS)
@TC (
o
C)
IFSM (AMPS)
12
150
300
16
150
325
20
150
350
40
150
800
CASE
VRRM (VOLTS)
100
200
400
600
800
1000
1200
CR12-010
CR12-020
CR12-040
CR12-060
CR12-080
CR12-100
CR12-120
DO-4*
DO-5*
CR16-010
CR16-020
CR16-040
CR16-060
CR16-080
CR16-100
CR16-120
CR20-010
CR20-020
CR20-040
CR20-060
CR20-080
CR20-100
CR20-120
CR40-010
CR40-020
CR40-040
CR40-060
CR40-080
CR40-100
CR40-120
VF MAX @ IF =IO
1.1V
1.1V
1.1V
1.1V
IR MAX @ VRRM
10µA
10µA
10µA
100µA
* Standard polarity is cathode to case. For reverse polarity add “R” suffix to part number.
(6-December 2004)
w w w. c e n t r a l s e m i . c o m
OUTSTANDING SUPPORT AND SUPERIOR SERVICES
PRODUCT SUPPORT
Central’s operations team provides the highest level of support to insure product is delivered on-time.
• Supply management (Customer portals)
• Custom bar coding for shipments
• Inventory bonding
• Custom product packing
• Consolidated shipping options
DESIGNER SUPPORT/SERVICES
Central’s applications engineering team is ready to discuss your design challenges. Just ask.
• Free quick ship samples (2
nd
day air)
• Special wafer diffusions
• Online technical data and parametric search
• PbSn plating options
• SPICE models
• Package details
• Custom electrical curves
• Application notes
• Environmental regulation compliance
• Application and design sample kits
• Customer specific screening
• Custom product and package development
• Up-screening capabilities
REQUESTING PRODUCT PLATING
1.
2.
If requesting Tin/Lead plated devices, add the suffix “ TIN/LEAD” to the part number when
ordering (example: 2N2222A TIN/LEAD).
If requesting Lead (Pb) Free plated devices, add the suffix “ PBFREE” to the part number
when ordering (example: 2N2222A PBFREE).
CONTACT US
Corporate Headquarters & Customer Support Team
Central Semiconductor Corp.
145 Adams Avenue
Hauppauge, NY 11788 USA
Main Tel: (631) 435-1110
Main Fax: (631) 435-1824
Support Team Fax: (631) 435-3388
www.centralsemi.com
Worldwide Field Representatives:
www.centralsemi.com/wwreps
Worldwide Distributors:
www.centralsemi.com/wwdistributors
For the latest version of Central Semiconductor’s
LIMITATIONS AND DAMAGES DISCLAIMER,
which is part of Central’s Standard Terms and Conditions of sale, visit: www.centralsemi.com/terms
w w w. c e n t r a l s e m i . c o m
(001)
http://www.centralsemi.com
PDN01088
5/31/18
11/30/18
5/31/19
Summary:The CR40-080 General Purpose Rectifier is discontinued and now classified as End of Life (EOL).
Although Central Semiconductor Corp. makes every effort to continue to produce devices that have been proclaimed EOL (End of Life) by
other manufacturers, it is an accepted industry practice to discontinue certain devices when customer demand falls below a minimum level of
sustainability. Accordingly, the following product(s) have been transitioned to End of Life status as part of Central's ongoing Product
Management Process. Any replacement products are noted below. The effective date for placing last purchase orders will be six (6) months
from the date of this notice and twelve (12) months from the notice date for final shipments, and minimum order quantities may apply.
The last purchase and shipment dates may be extended if inventory is available.
Central Part Number
CR40-080
Replacement
N/A
Central would be happy to assist you by providing additional information or technical data to help locate an alternate source if we
have no replacement available. Please email your requests to engineering@centralsemi.com.