Current Sense Transformers
CST306-2T
Description:
Designed for switching power supply applications, Triad current sense
transformers are used to detect the current passing through a conductor.
These transformers are very reliable and operate over the frequency range of
20 kHz-200 kHz.
Electrical Specifications (@25C)
ET VµSEC
REF 20kHz
1000
Turns
Count
100 CT
Min.
Ind. mH
14.0
DCR Max. Ω
1.550
Pri. Amps
25.0 RMS
Safety:
These current sense transformers are constructed of UL rated 130°C materials.
Dimensions:
A
Min
.180
B
Max
.915
C
Ref
.528
D
Ref
.127
E
Ref
.500
F
Max
.385
G
Max
.690
H
Ref
.250
H
Dia. Pins
.032
C
A
B
Units: In inches
D
Technical Notes:
1. Derate ET product by 32% for 50 kHz, 52% for 100 kHz and 50% for
unidirectional operation.
2. Rated primary current renders approximately 40°C temp. rise.
3. Maximum recommended terminating resistance of 1 ohm per turn.
4. Primary is inserted through hole in casting.
PIN 1
1. START OF TEST CONDUCTOR TO HAVE
THE SAME POLARITY AS PIN 1
2. DECAL ARROW ON CASE TO INDICATE
POLARITY
TEST CONDUCTOR
E
H
F
C
L
G
I
ST
ARROW
FN
1
POLARITY DETAIL TOP VIEW
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version.
For soldering and washing information please see
http://www.triadmagnetics.com/faq.html
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: June 7, 2016