DM-CT-100 Current Transducer
CAT
600V
• Optional accessory for Amprobe
digital recorders*
• Current measurement from 0.5A to 100A
• Maximum conductor size:
diameter 0.59” (15mm)
bus bar 0.59” (15mm) x 0.67” (17mm)
• Output sensitivity 10mV / A
• Basic accuracy:
0.5A to 10A +/- (3% + 5 mV)
10A to 50A +/- (2% + 5 mV)
50A to 100A +/- (1% + 5 mV)
• Safety: CAT III 600V
*Verify recorder compatibility with Amprobe catalog
or on our website: www.Amprobe.com
General Data
Maximum conductor size
15mm diameter, bus bar 15x17mm
Operating/ Storage Temperature -10ºC to +55ºC / -20ºC to +70ºC (14°F to 131°F/-4°F to 158°F)
Enclosure Protectio
Weight
Output Connection
Overheating will occur if the
product is subjected to
Power measurement
IP20 (EN 60529)
175 g
2m lead with D01 connector
(Ip rms x frequency) > 1,000,000. Limit measurement time
Respect the conventional P1=S1 direction of the arrow on the
probe. (see drawing)
Miramar, FL 33025 • Toll Free: 800-327-5060 • Phone: 954-499-5400 • Fax: 866-287-7222 • www.Amprobe.com
www.AMPROBE.com