首页 > 器件类别 > 可编程逻辑器件 > 可编程逻辑

EP2AGX95HF25C5

Field Programmable Gate Array

器件类别:可编程逻辑器件    可编程逻辑   

厂商名称:Altera (Intel)

下载文档
器件参数
参数名称
属性值
是否无铅
含铅
是否Rohs认证
不符合
厂商名称
Altera (Intel)
包装说明
,
Reach Compliance Code
compliant
JESD-609代码
e0
峰值回流温度(摄氏度)
NOT SPECIFIED
可编程逻辑类型
FIELD PROGRAMMABLE GATE ARRAY
端子面层
TIN LEAD
处于峰值回流温度下的最长时间
NOT SPECIFIED
Base Number Matches
1
文档预览
1. Device Datasheet for Arria II Devices
December 2013
AIIGX53001-4.4
AIIGX53001-4.4
This chapter describes the electrical and switching characteristics of the Arria
®
II
device family. The Arria II device family includes the Arria II GX and GZ devices.
Electrical characteristics include operating conditions and power consumption.
Switching characteristics include transceiver specifications, core, and periphery
performance. This chapter also describes I/O timing, including programmable I/O
element (IOE) delay and programmable output buffer delay.
f
For information regarding the densities and packages of devices in the Arria II device
family, refer to
Overview for the Arria II Device Family
chapter.
This chapter contains the following sections:
“Electrical Characteristics” on page 1–1
“Transceiver Performance Specifications” on page 1–21
“Glossary” on page 1–74
Electrical Characteristics
The following sections describe the electrical characteristics.
Operating Conditions
Arria II devices are rated according to a set of defined parameters. To maintain the
highest possible performance and reliability of Arria II devices, you must consider the
operating requirements described in this chapter.
Arria II devices are offered in both commercial and industrial grades. Arria II GX
devices are offered in –4 (fastest), –5, and –6 (slowest) commercial speed grades and
–3 and –5 industrial speed grades. Arria II GZ devices are offered in –3 and –4 speed
grades for both commercial and industrial grades.
1
In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades; commercial with the "C" prefix and industrial with the “I” prefix.
Commercial devices are indicated as C4, C5, and C6 speed grade, and the industrial
devices are indicated as I3 and I5.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for Arria II
devices. The values are based on experiments conducted with the device and
theoretical modeling of breakdown and damage mechanisms. The functional
operation of the device is not implied under these conditions.
Table 1–1
lists the
absolute maximum ratings for Arria II GX devices.
Table 1–2
lists the absolute
maximum ratings for Arria II GZ devices.
© 2013 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX are Reg. U.S. Pat. & Tm. Off.
and/or trademarks of Altera Corporation in the U.S. and other countries. All other trademarks and service marks are the property of their respective holders as described at
www.altera.com/common/legal.html.
Altera warrants performance of its semiconductor products to current specifications in accordance with Altera’s standard warranty, but
reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any
information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
December 2013
Subscribe
1–2
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
c
Conditions beyond those listed in
Table 1–1
and
Table 1–2
may cause permanent
damage to the device. Additionally, device operation at the absolute maximum
ratings for extended periods of time may have adverse effects on the device.
Table 1–1
lists the absolute maximum ratings for Arria II GX devices.
Table 1–1. Absolute Maximum Ratings for Arria II GX Devices
Symbol
V
CC
V
CCCB
V
CCBAT
V
CCPD
V
CCIO
V
CCD_PLL
V
CCA_PLL
V
I
I
OUT
V
CCA
V
CCL_GXB
V
CCH_GXB
T
J
T
STG
Description
Supplies power to the core, periphery, I/O registers, PCI Express
®
(PIPE) (PCIe) HIP block, and transceiver PCS
Supplies power for the configuration RAM bits
Battery back-up power supply for design security volatile key register
Supplies power to the I/O pre-drivers, differential input buffers, and
MSEL circuitry
Supplies power to the I/O banks
Supplies power to the digital portions of the PLL
Supplies power to the analog portions of the PLL and device-wide
power management circuitry
DC input voltage
DC output current, per pin
Supplies power to the transceiver PMA regulator
Supplies power to the transceiver PMA TX, PMA RX, and clocking
Supplies power to the transceiver PMA output (TX) buffer
Operating junction temperature
Storage temperature (no bias)
Minimum
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–25
–55
–65
Maximum
1.35
1.8
3.75
3.75
3.9
1.35
3.75
4.0
40
3.75
1.21
1.8
125
150
Unit
V
V
V
V
V
V
V
V
mA
V
V
V
°C
°C
Table 1–2
lists the absolute maximum ratings for Arria II GZ devices.
Table 1–2. Absolute Maximum Ratings for Arria II GZ Devices (Part 1 of 2)
Symbol
V
CC
V
CCCB
V
CCPGM
V
CCAUX
V
CCBAT
V
CCPD
V
CCIO
V
CC_CLKIN
V
CCD_PLL
V
CCA_PLL
V
I
I
OUT
Description
Supplies power to the core, periphery, I/O registers, PCIe HIP block, and
transceiver PCS
Power supply to the configuration RAM bits
Supplies power to the configuration pins
Auxiliary supply
Supplies battery back-up power for design security volatile key register
Supplies power to the I/O pre-drivers, differential input buffers, and
MSEL circuitry
Supplies power to the I/O banks
Supplies power to the differential clock input
Supplies power to the digital portions of the PLL
Supplies power to the analog portions of the PLL and device-wide
power management circuitry
DC input voltage
DC output current, per pin
Minimum
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-25
Maximum
1.35
1.8
3.75
3.75
3.75
3.75
3.9
3.75
1.35
3.75
4.0
40
Unit
V
V
V
V
V
V
V
V
V
V
V
mA
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
December 2013 Altera Corporation
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
1–3
Table 1–2. Absolute Maximum Ratings for Arria II GZ Devices (Part 2 of 2)
Symbol
V
CCA_L
V
CCA_R
V
CCHIP_L
V
CCR_L
V
CCR_R
V
CCT_L
V
CCT_R
V
CCL_GXBLn
(1)
V
CCL_GXBRn
(1)
V
CCH_GXBLn
(1)
V
CCH_GXBRn
(1)
T
J
T
STG
Description
Supplies transceiver high voltage power (left side)
Supplies transceiver high voltage power (right side)
Supplies transceiver HIP digital power (left side)
Supplies receiver power (left side)
Supplies receiver power (right side)
Supplies transmitter power (left side)
Supplies transmitter power (right side)
Supplies power to the transceiver PMA TX, PMA RX, and clocking (left
side)
Supplies power to the transceiver PMA TX, PMA RX, and clocking (right
side)
Supplies power to the transceiver PMA output (TX) buffer (left side)
Supplies power to the transceiver PMA output (TX) buffer (right side)
Operating junction temperature
Storage temperature (no bias)
Minimum
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-0.5
-55
-65
Maximum
3.75
3.75
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.8
1.8
125
150
Unit
V
V
V
V
V
V
V
V
V
V
V
°C
°C
Note to
Table 1–2:
(1) n = 0, 1, or 2.
Maximum Allowed Overshoot and Undershoot Voltage
During transitions, input signals may overshoot to the voltage shown in
Table 1–3
and
undershoot to –2.0 V for magnitude of currents less than 100 mA and periods shorter
than 20 ns.
Table 1–3
lists the Arria II GX and GZ maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the device lifetime. The
maximum allowed overshoot duration is specified as a percentage of high-time over
the lifetime of the device. A DC signal is equivalent to 100% duty cycle. For example,
a signal that overshoots to 4.3 V can only be at 4.3 V for 5.41% over the lifetime of the
device; for a device lifetime of 10 years, this amounts to 5.41/10ths of a year.
December 2013
Altera Corporation
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
1–4
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
Table 1–3. Maximum Allowed Overshoot During Transitions for Arria II Devices
Symbol
Description
Condition (V)
4.0
4.05
4.1
4.15
4.2
4.25
V
I
(AC)
AC Input Voltage
4.3
4.35
4.4
4.45
4.5
4.55
4.6
Overshoot Duration as % of
High Time
100.000
79.330
46.270
27.030
15.800
9.240
5.410
3.160
1.850
1.080
0.630
0.370
0.220
Unit
%
%
%
%
%
%
%
%
%
%
%
%
%
Maximum Allowed I/O Operating Frequency
Table 1–4
lists the maximum allowed I/O operating frequency for Arria II GX I/Os
using the specified I/O standards to ensure device reliability.
Table 1–4. Maximum Allowed I/O Operating Frequency for Arria II GX Devices
I/O Standard
HSTL-18 and HSTL-15
SSTL -15
SSTL-18
2.5-V LVCMOS
3.3-V and 3.0-V LVTTL
3.3-V, 3.0-V, 1.8-V, and 1.5-V LVCMOS
PCI and PCI-X
SSTL-2
1.2-V LVCMOS HSTL-12
200
250
I/O Frequency (MHz)
333
400
333
260
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
December 2013 Altera Corporation
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
1–5
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Arria II GX and GZ devices. All supplies are required to monotonically reach their
full-rail values without plateaus within t
RAMP
.
Table 1–5
lists the recommended operating conditions for Arria II GX devices.
Table 1–5. Recommended Operating Conditions for Arria II GX Devices
(Note 1)
(Part 1 of 2)
Symbol
V
CC
V
CCCB
V
CCBAT
(2)
V
CCPD
(3)
Description
Supplies power to the core, periphery, I/O
registers, PCIe HIP block, and transceiver
PCS
Supplies power to the configuration RAM
bits
Battery back-up power supply for design
security volatile key registers
Supplies power to the I/O pre-drivers,
differential input buffers, and MSEL
circuitry
Condition
Minimum
0.87
Typical
0.90
Maximum
0.93
Unit
V
1.425
1.2
3.135
2.85
2.375
3.135
2.85
2.375
1.71
1.425
1.14
0.87
1.50
3.3
3.0
2.5
3.3
3.0
2.5
1.8
1.5
1.2
0.90
1.575
3.3
3.465
3.15
2.625
3.465
3.15
2.625
1.89
1.575
1.26
0.93
V
V
V
V
V
V
V
V
V
V
V
V
V
CCIO
Supplies power to the I/O banks
(4)
V
CCD_PLL
V
CCA_PLL
V
I
V
O
V
CCA
V
CCL_GXB
V
CCH_GXB
T
J
Supplies power to the digital portions of the
PLL
Supplies power to the analog portions of
the PLL and device-wide power
management circuitry
DC Input voltage
Output voltage
Supplies power to the transceiver PMA
regulator
Supplies power to the transceiver PMA TX,
PMA RX, and clocking
Supplies power to the transceiver PMA
output (TX) buffer
Operating junction temperature
Commercial
Industrial
2.375
–0.5
0
2.375
1.045
1.425
0
–40
2.5
2.5
1.1
1.5
2.625
3.6
V
CCIO
2.625
1.155
1.575
85
100
V
V
V
V
V
V
°C
°C
December 2013
Altera Corporation
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
查看更多>
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消