are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html.
Altera warrants performance of its
semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and
services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service
described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying
on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
Cyclone IV Device Handbook,
Volume 3
March 2016
Feedback Subscribe
1–2
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1
Cyclone IV E industrial devices I7 are offered with extended operating temperature
range.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for Cyclone IV
devices. The values are based on experiments conducted with the device and
theoretical modeling of breakdown and damage mechanisms. The functional
operation of the device is not implied at these conditions.
Table 1–1
lists the absolute
maximum ratings for Cyclone IV devices.
c
Conditions beyond those listed in
Table 1–1
cause permanent damage to the device.
Additionally, device operation at the absolute maximum ratings for extended periods
of time have adverse effects on the device.
Table 1–1. Absolute Maximum Ratings for Cyclone IV Devices
(1)
Symbol
V
CCINT
V
CCA
V
CCD_PLL
V
CCIO
V
CC_CLKIN
V
CCH_GXB
V
CCA_GXB
V
CCL_GXB
V
I
I
OUT
T
STG
T
J
Parameter
Core voltage, PCI Express
(PCIe
) hard IP
block, and transceiver physical coding sublayer
(PCS) power supply
Phase
-
locked loop (PLL) analog power supply
PLL digital power supply
I/O banks power supply
Differential clock input pins power supply
Transceiver output buffer power supply
Transceiver physical medium attachment (PMA)
and auxiliary power supply
Transceiver PMA and auxiliary power supply
DC input voltage
DC output current, per pin
Storage temperature
Operating junction temperature
Min
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–25
–65
–40
Max
1.8
3.75
1.8
3.75
4.5
3.75
3.75
1.8
4.2
40
150
125
Unit
V
V
V
V
V
V
V
V
V
mA
°C
°C
Note to
Table 1–1:
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
power supply.
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage shown in
Table 1–2
and
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns.
Table 1–2
lists the maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as a percentage of high-time
over the lifetime of the device.
Cyclone IV Device Handbook,
Volume 3
March 2016 Altera Corporation
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1–3
1
A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to
4.3 V can only be at 4.3 V for 65% over the lifetime of the device; for a device lifetime
of 10 years, this amounts to 65/10ths of a year.
Table 1–2. Maximum Allowed Overshoot During Transitions over a 10
-
Year Time Frame for
Cyclone IV Devices
Symbol
Parameter
Condition (V)
V
I
= 4.20
V
I
= 4.25
V
I
= 4.30
V
i
AC Input
Voltage
V
I
= 4.35
V
I
= 4.40
V
I
= 4.45
V
I
= 4.50
V
I
= 4.55
V
I
= 4.60
Overshoot Duration as % of High Time
100
98
65
43
29
20
13
9
6
Unit
%
%
%
%
%
%
%
%
%
Figure 1–1
shows the methodology to determine the overshoot duration. The
overshoot voltage is shown in red and is present on the input pin of the Cyclone IV
device at over 4.3 V but below 4.4 V. From
Table 1–2,
for an overshoot of 4.3 V, the
percentage of high time for the overshoot can be as high as 65% over a 10-year period.
Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period
assumes that the device is always turned on with 100% I/O toggle rate and 50% duty
cycle signal. For lower I/O toggle rates and situations in which the device is in an idle
state, lifetimes are increased.
Figure 1–1. Cyclone IV Devices Overshoot Duration
4.4 V
4.3 V
3.3 V
DT
T
March 2016
Altera Corporation
Cyclone IV Device Handbook,
Volume 3
1–4
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone IV devices.
Table 1–3
and
Table 1–4
list the steady-state voltage and current
values expected from Cyclone IV E and Cyclone IV GX devices. All supplies must be
strictly monotonic without plateaus.
Table 1–3. Recommended Operating Conditions for Cyclone IV E Devices
(1),
Symbol
Parameter
Supply voltage for internal logic,
1.2-V operation
Supply voltage for internal logic,
1.0-V operation
Supply voltage for output buffers,
3.3-V operation
Supply voltage for output buffers,
3.0-V operation
Supply voltage for output buffers,
2.5-V operation
Supply voltage for output buffers,
1.8-V operation
Supply voltage for output buffers,
1.5-V operation
Supply voltage for output buffers,
1.2-V operation
V
CCA
(3)
(2)
(Part 1 of 2)
Min
1.15
0.97
3.135
2.85
2.375
1.71
1.425
1.14
2.375
1.15
0.97
–0.5
0
0
–40
–40
–40
50 µs
50 µs
Typ
1.2
1.0
3.3
3
2.5
1.8
1.5
1.2
2.5
1.2
1.0
—
—
—
—
—
—
—
—
Max
1.25
1.03
3.465
3.15
2.625
1.89
1.575
1.26
2.625
1.25
1.03
3.6
V
CCIO
85
100
125
125
50 ms
3 ms
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
°C
°C
°C
°C
—
—
Conditions
—
—
—
—
—
—
—
—
—
—
—
—
—
For commercial use
For industrial use
For extended temperature
For automotive use
Standard power-on reset
(POR)
(5)
Fast POR
(6)
V
CCINT
(3)
V
CCIO
(3), (4)
Supply (analog) voltage for PLL
regulator
Supply (digital) voltage for PLL,
1.2-V operation
Supply (digital) voltage for PLL,
1.0-V operation
Input voltage
Output voltage
V
CCD_PLL
(3)
V
I
V
O
T
J
Operating junction temperature
t
RAMP
Power supply ramp time
Cyclone IV Device Handbook,
Volume 3
March 2016 Altera Corporation
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1–5
Table 1–3. Recommended Operating Conditions for Cyclone IV E Devices
(1),
Symbol
I
Diode
Parameter
Magnitude of DC current across
PCI-clamp diode when enable
Conditions
—
(2)
(Part 2 of 2)
Min
—
Typ
—
Max
10
Unit
mA
Notes to
Table 1–3:
(1) Cyclone IV E 1.0 V core voltage devices only support C8L, C9L, and I8L speed grades. Cyclone IV E 1.2 V core voltage devices only support
C6, C7, C8, I7, and A7 speed grades.
(2) V
CCIO
for all I/O banks must be powered up during device operation. All
VCCA
pins must be powered to 2.5 V (even when PLLs are not used)
and must be powered up and powered down at the same time.
(3) V
CC
must rise monotonically.
(4) V
CCIO
powers all input buffers.
(5) The POR time for Standard POR ranges between 50 and 200 ms. Each individual power supply must reach the recommended operating range
within 50 ms.
(6) The POR time for Fast POR ranges between 3 and 9 ms. Each individual power supply must reach the recommended operating range within
3 ms.
Table 1–4. Recommended Operating Conditions for Cyclone IV GX Devices (Part 1 of 2)
1、函数定位: 假如要把C源文件 tools.c 中的函数 int BIN2HEX(int xx) { ... } 放在CODE MEMORY的0x1000处,先编译该工程,然后打开该工程的M51文件,在 * * * C O D E M E M O R Y * * * 行下找出要定位的函数的名称,应该形如: CODE xxxxH xxxxH UNIT ?PR?_BCD2H...[详细]
最近魏少军教授在谈及中国 AI (人工智能)芯片产业的现状时说:“现在 AI 芯片的炒作过头了,今天的一部分甚至大部分的 AI 芯片创业者会成为技术变革的‘先烈’”。魏少军的话不是空穴来风,仅仅一两年间,国内AI芯片头部创业公司的融资额度就超过了20亿人民币。全球至少有45家初创公司研制AI芯片(语音交互和自动驾驶),5家企业融资超过了1亿美元。据中信证券测算,2020年AI芯片市场规模将达...[详细]