器件参数
参数名称
属性值
LAB/CLB 数
963
逻辑元件/单元数
15408
总 RAM 位数
516096
I/O 数
165
电压 - 电源
1.15 V ~ 1.25 V
安装类型
表面贴装
工作温度
0°C ~ 85°C(TJ)
封装/外壳
256-TFBGA
供应商器件封装
256-MBGA(9x9)
文档预览
1. Cyclone IV Device Datasheet
March 2016
CYIV-53001-2.0
CYIV-53001-2.0
This chapter describes the electrical and switching characteristics for Cyclone
IV
devices. Electrical characteristics include operating conditions and power
consumption. Switching characteristics include transceiver specifications, core, and
periphery performance. This chapter also describes I/O timing, including
programmable I/O element (IOE) delay and programmable output buffer delay.
This chapter includes the following sections:
“Operating Conditions” on page 1–1
“Power Consumption” on page 1–16
“Switching Characteristics” on page 1–16
“I/O Timing” on page 1–37
“Glossary” on page 1–37
Operating Conditions
When Cyclone IV devices are implemented in a system, they are rated according to a
set of defined parameters. To maintain the highest possible performance and
reliability of Cyclone IV devices, you must consider the operating requirements
described in this chapter.
Cyclone IV devices are offered in commercial, industrial, extended industrial and,
automotive grades. Cyclone IV E devices offer –6 (fastest), –7, –8, –8L, and –9L speed
grades for commercial devices, –8L speed grades for industrial devices, and –7 speed
grade for extended industrial and automotive devices. Cyclone IV GX devices offer
–6 (fastest), –7, and –8 speed grades for commercial devices and –7 speed grade for
industrial devices.
f
For more information about the supported speed grades for respective Cyclone IV
devices, refer to the
Cyclone IV FPGA Device Family Overview
chapter.
1
Cyclone IV E devices are offered in core voltages of 1.0 and 1.2 V. Cyclone IV E
devices with a core voltage of 1.0 V have an ‘L’ prefix attached to the speed grade.
In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades; commercial with a “C” prefix, industrial with an “I” prefix, and
automotive with an “A” prefix. Therefore, commercial devices are indicated as C6, C7,
C8, C8L, or C9L per respective speed grade. Industrial devices are indicated as I7, I8,
or I8L. Automotive devices are indicated as A7.
© 2016 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos
are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html.
Altera warrants performance of its
semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and
services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service
described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying
on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
Cyclone IV Device Handbook,
Volume 3
March 2016
Feedback Subscribe
1–2
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1
Cyclone IV E industrial devices I7 are offered with extended operating temperature
range.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for Cyclone IV
devices. The values are based on experiments conducted with the device and
theoretical modeling of breakdown and damage mechanisms. The functional
operation of the device is not implied at these conditions.
Table 1–1
lists the absolute
maximum ratings for Cyclone IV devices.
c
Conditions beyond those listed in
Table 1–1
cause permanent damage to the device.
Additionally, device operation at the absolute maximum ratings for extended periods
of time have adverse effects on the device.
Table 1–1. Absolute Maximum Ratings for Cyclone IV Devices
(1)
Symbol
V
CCINT
V
CCA
V
CCD_PLL
V
CCIO
V
CC_CLKIN
V
CCH_GXB
V
CCA_GXB
V
CCL_GXB
V
I
I
OUT
T
STG
T
J
Parameter
Core voltage, PCI Express
(PCIe
) hard IP
block, and transceiver physical coding sublayer
(PCS) power supply
Phase
-
locked loop (PLL) analog power supply
PLL digital power supply
I/O banks power supply
Differential clock input pins power supply
Transceiver output buffer power supply
Transceiver physical medium attachment (PMA)
and auxiliary power supply
Transceiver PMA and auxiliary power supply
DC input voltage
DC output current, per pin
Storage temperature
Operating junction temperature
Min
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–25
–65
–40
Max
1.8
3.75
1.8
3.75
4.5
3.75
3.75
1.8
4.2
40
150
125
Unit
V
V
V
V
V
V
V
V
V
mA
°C
°C
Note to
Table 1–1:
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
power supply.
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage shown in
Table 1–2
and
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns.
Table 1–2
lists the maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as a percentage of high-time
over the lifetime of the device.
Cyclone IV Device Handbook,
Volume 3
March 2016 Altera Corporation
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1–3
1
A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to
4.3 V can only be at 4.3 V for 65% over the lifetime of the device; for a device lifetime
of 10 years, this amounts to 65/10ths of a year.
Table 1–2. Maximum Allowed Overshoot During Transitions over a 10
-
Year Time Frame for
Cyclone IV Devices
Symbol
Parameter
Condition (V)
V
I
= 4.20
V
I
= 4.25
V
I
= 4.30
V
i
AC Input
Voltage
V
I
= 4.35
V
I
= 4.40
V
I
= 4.45
V
I
= 4.50
V
I
= 4.55
V
I
= 4.60
Overshoot Duration as % of High Time
100
98
65
43
29
20
13
9
6
Unit
%
%
%
%
%
%
%
%
%
Figure 1–1
shows the methodology to determine the overshoot duration. The
overshoot voltage is shown in red and is present on the input pin of the Cyclone IV
device at over 4.3 V but below 4.4 V. From
Table 1–2,
for an overshoot of 4.3 V, the
percentage of high time for the overshoot can be as high as 65% over a 10-year period.
Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period
assumes that the device is always turned on with 100% I/O toggle rate and 50% duty
cycle signal. For lower I/O toggle rates and situations in which the device is in an idle
state, lifetimes are increased.
Figure 1–1. Cyclone IV Devices Overshoot Duration
4.4 V
4.3 V
3.3 V
DT
T
March 2016
Altera Corporation
Cyclone IV Device Handbook,
Volume 3
1–4
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone IV devices.
Table 1–3
and
Table 1–4
list the steady-state voltage and current
values expected from Cyclone IV E and Cyclone IV GX devices. All supplies must be
strictly monotonic without plateaus.
Table 1–3. Recommended Operating Conditions for Cyclone IV E Devices
(1),
Symbol
Parameter
Supply voltage for internal logic,
1.2-V operation
Supply voltage for internal logic,
1.0-V operation
Supply voltage for output buffers,
3.3-V operation
Supply voltage for output buffers,
3.0-V operation
Supply voltage for output buffers,
2.5-V operation
Supply voltage for output buffers,
1.8-V operation
Supply voltage for output buffers,
1.5-V operation
Supply voltage for output buffers,
1.2-V operation
V
CCA
(3)
(2)
(Part 1 of 2)
Min
1.15
0.97
3.135
2.85
2.375
1.71
1.425
1.14
2.375
1.15
0.97
–0.5
0
0
–40
–40
–40
50 µs
50 µs
Typ
1.2
1.0
3.3
3
2.5
1.8
1.5
1.2
2.5
1.2
1.0
Max
1.25
1.03
3.465
3.15
2.625
1.89
1.575
1.26
2.625
1.25
1.03
3.6
V
CCIO
85
100
125
125
50 ms
3 ms
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
°C
°C
°C
°C
Conditions
For commercial use
For industrial use
For extended temperature
For automotive use
Standard power-on reset
(POR)
(5)
Fast POR
(6)
V
CCINT
(3)
V
CCIO
(3), (4)
Supply (analog) voltage for PLL
regulator
Supply (digital) voltage for PLL,
1.2-V operation
Supply (digital) voltage for PLL,
1.0-V operation
Input voltage
Output voltage
V
CCD_PLL
(3)
V
I
V
O
T
J
Operating junction temperature
t
RAMP
Power supply ramp time
Cyclone IV Device Handbook,
Volume 3
March 2016 Altera Corporation
Chapter 1: Cyclone IV Device Datasheet
Operating Conditions
1–5
Table 1–3. Recommended Operating Conditions for Cyclone IV E Devices
(1),
Symbol
I
Diode
Parameter
Magnitude of DC current across
PCI-clamp diode when enable
Conditions
(2)
(Part 2 of 2)
Min
Typ
Max
10
Unit
mA
Notes to
Table 1–3:
(1) Cyclone IV E 1.0 V core voltage devices only support C8L, C9L, and I8L speed grades. Cyclone IV E 1.2 V core voltage devices only support
C6, C7, C8, I7, and A7 speed grades.
(2) V
CCIO
for all I/O banks must be powered up during device operation. All
VCCA
pins must be powered to 2.5 V (even when PLLs are not used)
and must be powered up and powered down at the same time.
(3) V
CC
must rise monotonically.
(4) V
CCIO
powers all input buffers.
(5) The POR time for Standard POR ranges between 50 and 200 ms. Each individual power supply must reach the recommended operating range
within 50 ms.
(6) The POR time for Fast POR ranges between 3 and 9 ms. Each individual power supply must reach the recommended operating range within
3 ms.
Table 1–4. Recommended Operating Conditions for Cyclone IV GX Devices (Part 1 of 2)
Symbol
V
CCINT
V
CCA
(3)
Parameter
Core voltage, PCIe hard IP block, and
transceiver PCS power supply
PLL analog power supply
PLL digital power supply
I/O banks power supply for 3.3
-
V
operation
I/O banks power supply for 3.0
-
V
operation
I/O banks power supply for 2.5
-
V
operation
I/O banks power supply for 1.8
-
V
operation
I/O banks power supply for 1.5
-
V
operation
I/O banks power supply for 1.2
-
V
operation
Differential clock input pins power
supply for 3.3
-
V operation
Differential clock input pins power
supply for 3.0
-
V operation
Conditions
Min
1.16
2.375
1.16
3.135
2.85
2.375
1.71
1.425
1.14
3.135
2.85
2.375
1.71
1.425
1.14
2.375
Typ
1.2
2.5
1.2
3.3
3
2.5
1.8
1.5
1.2
3.3
3
2.5
1.8
1.5
1.2
2.5
Max
1.24
2.625
1.24
3.465
3.15
2.625
1.89
1.575
1.26
3.465
3.15
2.625
1.89
1.575
1.26
2.625
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
(1), (3)
(2)
V
CCD_PLL
V
CCIO
(3), (4)
V
CC_CLKIN
(3), (5), (6)
Differential clock input pins power
supply for 2.5
-
V operation
Differential clock input pins power
supply for 1.8
-
V operation
Differential clock input pins power
supply for 1.5
-
V operation
Differential clock input pins power
supply for 1.2
-
V operation
V
CCH_GXB
Transceiver output buffer power supply
March 2016
Altera Corporation
Cyclone IV Device Handbook,
Volume 3
查看更多>
产品电路板上的下载及调试接口问题
做的是可穿戴设备,设备上PCB板面积有限,想尽可能节省面积。 板上两颗芯片都需要下载程序,光留这...
b01010101 PCB设计
AD2S1205例程
本帖最后由 天明 于 2014-7-30 15:02 编辑 AD2S1205例程 ...
天明 ADI参考电路
求一个实现方案
需求描述: 某种机械设备,要求某个动作只能进行规定的时间。假设要求A动作做0.5秒。 目前的实现: ...
yytzc 嵌入式系统
G2553与12864的串行连接问题
G2553与12864的串行连接 需要怎么接线啊,G2553的io口比较少,串行是不是可以节省资源啊...
zwldsd 微控制器 MCU
AD采集分压电阻的选择
单片机AD采集测量范围0~2.56V,现在要测量一个24V~30V的锂电池电压,打算分压,然后AD采...
gxp790953623 单片机
HC32F4A0_FreeRTOS_LwIP移植
HC32F4A0-FreeRTOS移植 - 国产芯片交流 - 电子工程世界-论坛 (eewo...
Zachary_yo 国产芯片交流
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消