1000A Clamp Meters with IR Thermometers
Clamp-on multimeter with built-in non-contact InfraRed Thermometer
Ideal for industrial applications the 800 series Full size 1000A clamps feature a
built-in Infared thermometer and rugged double molded housing.
EX800 Series Features:
•
Non-contact InfraRed Temperature measurements
with laser pointer
•
Models with True RMS Current and Voltage
measurements
•
Peak hold captures inrush currents and Transients
•
MultiMeter functions include AC/DC Voltage,
Resistance, Capacitance, Frequency, Type K
Temperature (EX820/EX830), Diode, and Continuity
•
1.7" (43mm) jaw opening for conductors up to
750MCM or two 500MCM
•
4000 count backlit display
•
Features include Data Hold and Min/Max
•
Autoranging with manual range button
•
Auto Power off
•
Complete with test leads, 9V battery, general
purpose Type K probe (EX820/EX830), and case
Model EX810
•
AC Current
•
Average responding
Model EX820
•
AC Current
•
True RMS
•
Type K thermometer
Model EX830
•
DC/ AC Current
•
True RMS
•
Type K thermometer
•
DC Zero
Specifications
IR Temperature
(IR)
AC Current
DC Current
AC Voltage
DC Voltage
Resistance
Capacitance
Frequency
Type K Temperature
True RMS meter gives you accurate
readings of non-sinusoidal
waveforms.
Built-in IR Thermometer with laser
pointer is an excellent roubleshooter
for locating hot spots and
overheating motors.
EX810
-58 to 518ºF
-50 to 270ºC
0.1 to 1000A
—
0.1mV to 600V
0.1mV to 600V
0.1 to 40MΩ
0.001nF to 40,000μF
0.001kHz to 4kHz
—
Yes
Yes
Yes
0.6x4.3x2"
(270x110x50mm)
13.6oz (386g)
EX820
-58 to 518ºF
-50 to 270ºC
0.1 to 1000A
—
0.1mV to 600V
0.1mV to 600V
0.1 to 40MΩ
0.001nF to 40,000μF
0.001kHz to 4kHz
-4 to 1400ºF
-20 to 760ºC
Yes
Yes
Yes
10.6x4.3x2"
(270x110x50mm)
13.6oz (386g)
EX830
-58 to 518ºF
-50 to 270ºC
0.1 to 1000A
0.1 to 1000A
0.1mV to 600V
0.1mV to 600V
0.1 to 40MΩ
0.001nF to 40,000μF
0.001kHz to 4kHz
-4 to 1400ºF
-20 to 760ºC
Yes
Yes
Yes
10.6x4.3x2"
(270x110x50mm)
13.6oz (386g)
Basic Accuracy
±2.0% rdg or
±4ºF/±2ºC
±2.8% (EX810);
±2.5% (EX820, EX830)
±2.5%
±1.8% (EX810);
±1.5% (EX820, EX830)
±1.5%
±1.5%
±3.0%
±1.5%
±(3%rdg+9°F/5ºC)
Continuity
Inrush
Diode
Dimensions
Weight
Ordering Information:
EX810..................1000A
AC Clamp/DMM+IR Thermometer
EX810-NISTL*
....1000A AC Clamp/DMM+IR Thermometer w/ Calibration Traceable to NIST
EX820..................1000A
AC True RMS Clamp/DMM+IR Thermometer
EX820-NISTL*
....1000A AC True RMS Clamp/DMM+IR Thermometer w/ Calibration Traceable to NIST
EX830..................1000A
AC/DC True RMS Clamp/DMM+IR Thermometer
EX830-NISTL*
....1000A AC/DC True RMS Clamp/DMM+IR Thermometer w/ Calibration Traceable to NIST
*NISTL is a Limited NIST: Product is certified to all functions except IR Thermometer
www.extech.com
Specifications subject to change without notice.
3/19/12 - R1
Copyright © 2008-2011 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.