首页 > 器件类别 > 传感器

FEA121700G1S0N2K1A1A7A3B2Y0

Sensor/Transducer,

器件类别:传感器   

厂商名称:ABB

厂商官网:http://www.abb.com/

下载文档
器件参数
参数名称
属性值
Objectid
145181545785
Reach Compliance Code
unknown
其他特性
IP 67; IP68
主体高度
80 mm
主体长度或直径
100 mm
最高工作温度
60 °C
最低工作温度
-20 °C
封装主体材料
ALUMINIUM
封装形状/形式
CIRCULAR
传感器/温度传感器类型
LIQUID FLOW SENSOR
最大供电电压
26.4 V
最小供电电压
16.8 V
文档预览
A B B ME A SUREME NT & ANA LY TICS | DATA SHE ET
AquaProbe FEA100
Insertion-type electromagnetic flow
sensor with WaterMaster transmitter
Measurement made easy
Maximum performance,
minimum hassle
Suitable for permanent or temporary installation
• total user flexibility
The most stable transmitter in the world
• self-calibrating transmitter and ultra-low temperature coefficient for
highest accuracy
One solution for all your needs
• designed for use in all clean water applications
Quick transmitter exchange
• revolutionary data storage enables transmitter interchange /
commissioning without reconfiguration
Advanced infrared service port
• supports simultaneous and parallel operation of HART, remote HMI,
cyclic data output and parameter dump
OIML R49 permanent self-checking
• type P approved transmitter
• continuous self-checking of flow sensor and transmitter ensures
highest accuracy / long term performance
3-Year material defect warranty (AquaProbe sensor)
'Hot tap' capability
• enables installation with no interruption to water supply
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
3
AquaProbe FEA100
The AquaProbe FEA100 extends the capability of the ABB
AquaProbe flowmeter by bringing together the proven
AquaProbe flow sensor with the innovative WaterMaster
transmitter.
AquaProbe has been designed, in close consultation with the
water industry, as an economic alternative to full-bore
metering. It comprises an electromagnetic sensing head
mounted on the end of a support rod. The sensing head can
be installed in existing pipelines without the need for the
major excavations or alterations to pipework associated with
full-bore meters. It can be fitted without interrupting the
water supply and can be removed easily for periodic
calibration or inspection.
AquaProbe is designed for installation in existing pipelines by
means of a small valved tapping. It is normally installed with
the sensing head on the pipe centreline, but may be located
at the critical position (the mean velocity position) a distance
of 1/8 of the pipe diameter away from the wall.
It provides an accurate local measurement of the water
velocity and, provided the flow profile is developed fully, a
good flow volume measurement.
Figure 1
AquaProbe flow sensor
The high sensitivity of AquaProbe enables it to traverse the
pipe to establish the flow profile and so identify hydraulic
problems in complex systems or ensure maximum accuracy
from an AquaProbe that has been installed in a non-ideal
location.
If the profile is not fully developed, a traverse of the pipe can
be performed, enabling an accurate flow volume
measurement to be obtained in non-ideal networks.
Key features include the wide flow range with the minimum
measured velocity (well below that detected by insertion
turbine or DP devices), no moving parts resulting in increased
reliability and reduced maintenance.
AquaProbe is ideal for permanent installation to monitor
potable or clean water flow. Also through the provision of
multiple tappings on the supply pipelines, AquaProbe can be
used as a portable survey tool to assist in the building of an
accurate network model, locate leaks and check the operation
of installed full-bore meters.
Based on ABB-proven technology, AquaProbe is supported by
the expertise of ABB, the world’s leading flow meter
manufacturer with many pioneering advances in water flow
metering over the last decade – for example, AquaMag™,
WaterMaster™, AquaProbe™ and CalMaster™.
ABB operate nationally- and internationally-accredited flow
calibration facilities in the UK, Germany, USA, Australia, China
and India. We also offer comprehensive, locally based before-
and after-sales service.
4
AQ UA P RO B E F E A 10 0
I N S E R T I O N F LOW S E N S O R W I T H WAT E RMA STER T R A NS MIT TER | D S/F EA 100- EN REV. B
Comprehensive features
A wide range of features and user benefits are built into
WaterMaster as standard:
• bi-directional flow
• unique, self-calibrating transmitter (patent approval in
progress) for the ultimate in stability and repeatability
• OIML R49 Type P continuous self-checking transmitter,
with alarms, ensures both flow sensor and transmitter
accuracy
• true electrode and coil impedance measurement
• comprehensive simulation mode
• universal switch mode power supply (options are
available for AC and DC supplies)
• comprehensive self-diagnostics compliant with
NAMUR NE107
• programmable multiple alarm capability
• HART protocol over 4 to 20 mA and infrared link
• 3 configurable pulse / frequency and alarm outputs
• advanced infrared service port supports remote HMI,
HART, cyclic data out and parameter dump
• read-only switch and ultra-secure service password for
total security
• PROFIBUS DP v1 option
Menu
Easy Setup
Exit
Select
Figure 2
Comprehensive display
Figure 3 FEA100 remote system
AQ UA P R OB E F EA 100
I N S ER T I ON F LOW S E NS O R W IT H WAT E RM A ST E R T R AN SMI T TE R | D S/F EA 100- EN RE V. B
5
Support software
AquaProbe FEA100 also has on-board remote communication
ability, such as interfacing to PROFIBUS DP and HART, that
enables the user to collect data remotely.
ABB also supply ScrewDriver, an enhanced software that
provides users with all-round improved profile analysis, flow
profiling set-up, downloading and display options when used
in conjunction with a WaterMaster transmitter.
Improved performance through
Digital Signal Processing (DSP)
Advanced Digital Signal Processing (DSP) gives improved
performance and enables real-time measurements for
maximum reliability.
DSP enables the transmitter to separate the real signal from
the noise, providing high quality outputs especially in harsh
environments involving vibration, hydraulic noise and
temperature fluctuation.
Figure 4
PC software support
Intuitive navigation and configuration
The user-friendly interface enables fast and simple data entry
for all parameters. 'Easy Setup' guides the operator step-by-
step through the menu to set parameters as quickly as
possible, simplifying the commissioning phase.
查看更多>
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ