首页 > 器件类别 > 连接器

FHG.1B.307.CLAH72Z

CONN PLUG MALE 7POS SOLDER CUP

器件类别:连接器   

厂商名称:LEMO

厂商官网:http://www.lemo-china.com

器件标准:

下载文档
器件参数
参数名称
属性值
连接器类型
插头,公引脚
针脚数
7
外壳尺寸 - 插件
307
安装类型
自由悬挂,直角
端接
焊杯
紧固类型
推挽式,销锁
朝向
G
侵入防护
IP50 - 防尘
外壳材料,镀层
黄铜,镀铬
触头镀层
特性
屏蔽
额定电流
7A
触头镀层厚度
39.4µin(1.00µm)
工作温度
-55°C ~ 250°C
文档预览
unipole & multipole
connectors
No reproduction or use without express permission of editorial or pictorial content, in any manner.
LEMO reserve the right at all times to modify and improve specifications without any notification.
®
®
LEMO unipole and multipole connectors
This catalogue gives the complete description of LEMO unipole and multipole type connectors. The LEMO manufacturing
programme has been extended to almost 40 series divided into 7 product families with specific mating and environmental
characteristics. Each series includes a wide variety of plug, socket, coupler and bridge plug models, available in contact
configurations adapted to all round cables, including up to 114 conductors, and a maximum diameter of 30 mm.
Watertight and vacuumtight models are also available. Since LEMO connectors are perfectly screened and designed to
guarantee very low resistance to shell electrical continuity, they are particularly adapted to applications where electro-
magnetic compatibility (EMC) is important.
Table of Contents
3 steps to select the right connector
................................................................................................................................................................................ 3
B Series (indoor, keyed)
Part Numbering system ........................................................................................................................................................................................ 13
Metal Housing models ........................................................................................................................................................................................... 14
Elbow socket models ............................................................................................................................................................................................. 25
Plastic housing models .......................................................................................................................................................................................... 28
Watertight or vacuumtight models ......................................................................................................................................................................... 30
Bridge models ........................................................................................................................................................................................................ 34
Threaded-latching models ..................................................................................................................................................................................... 35
Alignment Key and Polarized Keying System........................................................................................................................................................ 36
K Series (outdoor, keyed)
Part Numbering system ......................................................................................................................................................................................... 38
Metal Housing models ........................................................................................................................................................................................... 39
Watertight or vacuumtight models ......................................................................................................................................................................... 47
Alignment Key and Polarized Keying System........................................................................................................................................................ 49
T Series (outdoor, keyed)
Part Numbering system ......................................................................................................................................................................................... 52
Metal Housing models ........................................................................................................................................................................................... 53
Watertight or vacuumtight models ......................................................................................................................................................................... 55
Plastic housing models, alignment Key and Polarized Keying System ................................................................................................................. 56
B, K and T Series
Insert configuration, Housings, Insulators, Contacts, Collets, Variant .................................................................................... 57
S Series (indoor, stepped insert)
Part Numbering system ........................................................................................................................................................................................ 75
Metal Housing models ........................................................................................................................................................................................... 76
Elbow socket models ............................................................................................................................................................................................. 87
Plastic housing models .......................................................................................................................................................................................... 89
Watertight or vacuumtight models ......................................................................................................................................................................... 91
E Series (outdoor, stepped insert)
Part Numbering system ......................................................................................................................................................................................... 94
Metal Housing models ........................................................................................................................................................................................... 95
Watertight or vacuumtight models ....................................................................................................................................................................... 101
S, and E Series
Insert configuration, Housings, Insulators, Contacts, Collets, Variant ...................................................................................... 103
M Series (outdoor, keyed)..............................................................................................................................................................................................
123
F Series (outdoor, keyed)
.............................................................................................................................................................................................. 125
Spare parts
...................................................................................................................................................................................................................... 127
Accessories
.................................................................................................................................................................................................................... 137
Tooling
............................................................................................................................................................................................................................. 151
Panel cut-outs and PCB drilling pattern
....................................................................................................................................................................... 157
Cable assembly
(B, K, T, S and E series)....................................................................................................................................................................... 169
Technical characteristics...............................................................................................................................................................................................
182
Product safety notice
..................................................................................................................................................................................................... 198
www.lemo.com
1
®
®
Precision modular connectors to suit your application
Over 75000 connectors
Since its creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull
connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in
more than 80 countries with the help of over 40 subsidiaries and distributors.
The modular design of the LEMO range provides over 75000 connectors from miniature ø 3 mm to ø 50 mm, capable of
handling cable diameters up to 30 mm and for up to 114 contacts.
LEMO’s Push-Pull Self-Latching Connection System
This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most
markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommuni-
cations and military.
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute
security against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
The LEMO self-latching system allows the connector
to be mated by simply pushing the plug axially into
the socket.
Once firmly latched, connection cannot be broken by
pulling on the cable or any other component part other
than the outer release sleeve.
When required, the connector is disengaged by a
single axial pull on the outer release sleeve.
This first disengages the latches and then withdraws
the plug from the socket.
LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO
connector, cable and your equipment) will be easier because LEMO connectors are recognized.
CE marking
means that the appliance or equipment bearing it complies with the protection requirements of one or
several European safety directives. CE marking
applies to complete products or equipment,
but not to electrome-
chanical components, such as connectors.
LEMO connector specifications conforms the requirements of the RoHS directive (2011/65/EU) of the European Parlia-
ment and the latest amendments. This directive specifies the restrictions of the use of hazardous substances in electrical
and electronic equipment marketed in Europe.
2
www.lemo.com
UL Recognition
CE marking
RoHS
®
®
l
Step 1: Select connector series
3 steps to select the right connector
Select the appropriate LEMO connector series according to the environmental parameters that will affect your device
or cable such as indoor, outdoor, temperature range, ingress protection of the mated connector and of your device.
Use the table shown on page 4.
Part number coding
.
l
Step 2: Select connector size
B, K, T, S or E
.
.
Use the section (mm
2
) or the AWG of your cable wire to select the optimal contact diameter (values vary between
solder, crimp or print contact), see page 8.
Use this optimal contact diameter to determine the right connector size as well as the insert configuration, see page 6.
Part number coding
.
l
Step 3: Complete the part number
0, 1, 2, 3, 4, 5 or 6
.
.
Now that you know the series, as well as the insulator configuration, complete the part numbering system with the help
of the following table.
Part number coding
.
.
.
B Series (indoor, keyed)
Model
39
76
14
Series
39
76
14
Insert
configuration
57
57
Housing
material
64
64
Insulator
material
64
64
Contact
64
64
Collet
68
67
Variant
71
71
T Series (outdoor, keyed)
K Series (outdoor, keyed)
S Series (indoor, stepped insert)
53
53
Note:
Figures in the above table refer to the catalogue pages.
E Series (outdoor, stepped insert)
95
95
103
103
57
112
112
64
112
112
64
112
112
64
119
115
70
121
121
71
www.lemo.com
3
查看更多>
[立创开源]初次尝试国民MCU之 N32G430电流表及快充采样
看到一篇不错的文章!分享给大家~ 内容已在立创开源了,开源地址: https://oshwh...
wangerxian 电源技术
《智能传感器设计》,传感器开发、设计参考书
本书作者是 Creed Huddleston,资深传感器设计专家。《智能传感器设计》介绍智能传感器...
arui1999 下载中心专版
求基于单片机的洗衣机和基于ARM的万年历的工程
求基于单片机的洗衣机和基于ARM的万年历的工程 求基于单片机的洗衣机和基于ARM的万年历的工程 ...
ns031 单片机
可否用u-boot来引导vxworks和linux双系统
u-boot来引导vxworks和linux双系统是否可行?另外, u-boot引导vxworks该...
813128 Linux与安卓
为什么在电路设计中会有蛇形走线?
作者认为主要牵涉到两个方便的问题: 1.差分线,就是题主发的图片中 电路 板上特别接近的两根...
lclhitwh 模拟与混合信号
我的这个系统如何实现低功耗?
我的这个系统包括:LCD12864显示,4*4键盘,双串口数据通讯 其中LCD12864要随时更新显...
hoohoo2002 微控制器 MCU
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消