Technical Data 1014
Effective August 2015
Supersedes January 2014
BUSSMANN
SERIES
LIMITRON™ FNQ-R Class CC 600Vac,
1⁄4-30A, time-delay fuses
Catalog numbers (amps)
FNQ-R-1⁄4
FNQ-R-3⁄10
FNQ-R-4⁄10
FNQ-R-1⁄2
FNQ-R-6⁄10
FNQ-R-3⁄4
FNQ-R-8⁄10
FNQ-R-1
FNQ-R-1-1⁄8
FNQ-R-1-1⁄4
FNQ-R-1-3⁄10 FNQ-R-3-2⁄10 FNQ-R-8
FNQ-R-1-4⁄10 FNQ-R-3-1⁄2
FNQ-R-1-1⁄2
FNQ-R-4
FNQ-R-1-6⁄10 FNQ-R-4-1⁄2
FNQ-R-1-8⁄10 FNQ-R-5
FNQ-R-2
FNQ-R-2-1⁄4
FNQ-R-2-1⁄2
FNQ-R-3
FNQ-R-6
FNQ-R-6-1⁄4
FNQ-R-7-1⁄2
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-20
FNQ-R-25
FNQ-R-30
FNQ-R-5-6⁄10 FNQ-R-17-1⁄2
FNQ-R-2-8⁄10 FNQ-R-7
Catalog symbol:
•
Carton quantity:
Amp rating
1⁄4-30
Carton qty.
10
FNQ-R-(amp)
Description:
Advanced protection Class CC current-limiting,
time-delay fuses.
Dimensions - in:
1.5" (± 0.031)
(38.1mm)
0.41" (± 0.005)
(10.3mm)
Specifications:
Ratings
•
Volts
•
600Vac
•
Features:
•
300Vdc (15 & 20A)
•
Provides 10X better current limitation to help
prevent equipment damage caused by short-
circuit events.
200kA interrupting rating complies with
NEC
®
Section 110.9 for today’s large capacity
systems.
Fast-acting fuse helps prevent equipment
damage caused by short-circuit events.
Rejection type fuse fits both standard and
rejection-style holders.
The Class CC FNQ-R Limitron fuse meets the
needs of control circuit transformer protection.
FNQ-R fuses can be sized according to NEC
®
and UL requirements and still allow the high
inrush currents, with significantly more time-
delay than the UL minimum value of 12
seconds at 200% for Class CC fuses.
Ideal for critical industrial or commercial
applications that have specific current limitation
requirements.
•
•
Amps 1⁄4-30A
IR
•
•
200kA Vac RMS Sym.
20kA Vdc (15 & 20A)
•
•
•
•
Agency information
•
•
•
•
UL
®
Listed, Std. 248-4, Class CC, Guide JDDZ,
File E4273
CSA
®
Certified, Class CC CSA, Class 1422-01,
File 53787–HRC-MISC
CE
RoHS compliant*
* FNQ-R-1⁄4 not RoHS complaint.
•
Technical Data 1014
Effective August 2015
LIMITRON™ FNQ-R Class CC 600Vac, 1⁄4-30A, time-delay fuses
Applications:
•
•
•
•
Branch circuits
Line protection
Small control transformers
Industrial control
Recommended fuse blocks and holders:
Fuse amps
0-30
1-Pole
BCM603-1_
CHCC1D_
0-30
—
—
—
0-30
HPS
HPF
0-30
—
HEZ
2-Pole
Modular open blocks
BCM603-2_
CHCC2D_
—
—
—
Panel mount holders
—
—
In-line holders
HEY
—
—
—
—
—
BCM603-3_
CHCC3D_
OPM-NG-_
OPM-1038_
OPM-1038_SW
DIN-Rail holders
3-Pole
For additional information on Class CC fuse blocks and holders, see
data sheets:
•
Modular open blocks # 10241 (BCM)
•
•
•
DIN-Rail holders No. 3185 (CHCC), No. 1109 (OPM), No. 1102
(OPM-1038), No. 1103 (OPM-1038_SW)
Panel mount holders No. 2113 (HPS), No. 2114 (HPF)
In-line holders No. 2126 (HEY), No. 2130 (HEZ)
2
Eaton.com/bussmannseries
LIMITRON™ FNQ-R Class CC 600Vac, 1⁄4-30A, time-delay fuses
Technical Data 1014
Effective August 2015
Time-current curves - average melt:
1⁄2 to 71⁄2 amps
1/2
6/10
3/4
8/10
1
1-1/8
1-1/4
1-1/2
1-8/10
2
2-1/2
3
3-2/10
3-1/2
4
5
5-6/10
6
6-1/4
7
7-1/2
AMP RATING
200
100
10
TIME IN SECONDS
1
0.1
CURRENT IN AMPS
Eaton.com/bussmannseries
100
200
300
400
500
0.5
10
1
0.01
3
Technical Data 1014
Effective August 2015
LIMITRON™ FNQ-R Class CC 600Vac, 1⁄4-30A, time-delay fuses
Time-current curves - average melt:
15 to 30 Amps
1000
AMP RATING
15A
20A
100
TIME IN SECONDS
10
1
0.1
0.01
1
10
30A
100
1000
CURRENT IN AMPS
4
Eaton.com/bussmannseries
10000
LIMITRON™ FNQ-R Class CC 600Vac, 1⁄4-30A, time-delay fuses
Technical Data 1014
Effective August 2015
Current-limitation curves:
1-1⁄2 to 7-1⁄2 amps
Eaton.com/bussmannseries
5