Shanghai Lunsure Electronic
Technology Co.,Ltd
Tel:0086-21-37185008
Fax:0086-21-57152769
FR301GP
THRU
FR307GP
3 Amp Fast Recovery
Rectifier
50 to 1000 Volts
DO-201AD
Features
•
•
•
•
•
•
Low Cost
Low Leakage
Low Forward Voltage Drop
High Current Capability
Fast Switching Speed For High Efficiency
Glass Passivated Junction
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Device
Marking
Maximum
Reccurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
40V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
Catalog
Number
FR301GP
FR302GP
FR303GP
FR304GP
FR305GP
FR306GP
FR307GP
D
---
---
---
---
---
---
---
A
Cathode
Mark
B
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
I
F(AV)
3A
T
A
= 55°C
Current
Peak Forward Surge
I
FSM
150A
8.3ms, half sine
Current
I
FM
= 3.0A;
Maximum
1.3V
Instantaneous
V
F
T
A
= 25°C
Forward Voltage
Maximum DC
Reverse Current At
I
R
5µA
T
A
= 25°C
Rated DC Blocking
100µA T
A
= 55°C
Voltage
Maximum Reverse
Recovery Time
150ns I
F
=0.5A, I
R
=1.0A,
FR301GP-304GP
T
rr
250ns I
rr
=0.25A
FR305GP
500ns
FR306GP-307GP
Typical Junction
C
J
50pF
Measured at
Capacitance
1.0MHz, V
R
=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
D
C
DIMENSIONS
INCHES
MIN
---
---
.048
1.000
MM
MIN
---
---
1.20
25.40
DIM
A
B
C
D
MAX
.370
.250
.052
---
MAX
9.50
6.40
1.30
---
NOTE
www.cnelectr.com
FR301GP thru FR307GP
Figure 1
Typical Forward Characteristics
20
10
6
4
2.5
2
25°C
Amps
1
.6
.4
.2
.1
.06
.04
.02
.01
.4
.6
.8
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
1.0
1.2
1.4
0
.5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
75
100
°C
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°C
125
150
175
Amps
1.0
2.0
3.0
Figure 2
Forward Derating Curve
1.5
Figure 3
Junction Capacitance
100
60
40
20
pF
T
J
=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
1000
Junction Capacitance - pF
versus
Reverse Voltage - Volts
www.cnelectr.com
FR301GP thru FR307GP
Figure 4
Peak Forward Surge Current
150
125
100
75
Amps
50
25
0
1
4
6
8 10
Cycles
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
20
40
60 80 100
2
Figure 5
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
t
rr
+0.5A
0
25Vdc
Pulse
Generator
Note 2
1Ω
Oscilloscope
Note 1
-0.25
-1.0
1cm
Set Time Base for 20/100ns/cm
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
www.cnelectr.com