Linear Power Supplies Data Sheet
Features
• RoHS compatible for all six substances
• Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
• ±0.05% Output Regulation
• Low Output Ripple
• UL, CSA, and TÜV Approvals
• Mean Time Before Failure (MTBF) in Excess of
300,000 Hours
• CE marked to Low Voltage Directive
• 100% Burn-In
• 2 Year Warranty
• Overvoltage Protection (OVP) Standard on 5V
Single Outputs, Optional for other outputs
under 48V
Description
Power-One produces the industry’s broadest selection of
Linear power supplies with output voltages from 5 volts
through 250 volts. Rugged technology and proven design
merge to create quiet, highly-regulated, dependable
DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to
the Low Voltage Directive (LVD).
Overvoltage Protection Options
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
OVP-12G
DUAL
OUTPUT
TRIPLE
OUTPUT
PEAK
CURRENT
MODELS
NOTE:
OVP SELECTION GUIDE
MODEL
CASE SIZE
OVP MODULES REQUIRED
SINGLE
OUTPUT
B,C,N,D
E,F
AA,B,BB,CC
E
AA,BAA,D
CBB, 131
DBB,DCC
N,BAA,CBB
131
(1) OVP-12G
(1) OVP-24G
(1) OVP-12G protects both outputs
(1) OVP-24G protects both outputs
(1) OVP-12G protects both 12V
through 15V outputs
(1) OVP-12G protects any output
not provided with built-in OVP
Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
OVP-24G
MCD10016 Rev. 1.2, 13-Nov-09
Page 1 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Unsigned output voltages are isolated and can be used as either + or - polarities.
Nominal
Vout*
5Vout
5
5
5
5
5
5
5
5
5
1.5
3
6
9
12
18
25
35
50
0.9
1.7
3.4
5.1
6.8
10.2
16
0.9
1.5
3
4.5
6
9
15
0.5
1.2
2.4
3.6
4.8
7.2
12
0.5
1
2
3
4
6
10
0.5
1
3
4
HA5-1.5/OVP-AG
HB5-3/OVP-AG
HC5-6/OVP-AG
HN5-9/OVP-AG
HD5-12/OVP-AG
HE5-18/OVP-AG
F5-25/OVP-AG
G5-35/OVP-AG
CP197-AG
HA15-0.9-AG
HB12-1.7-AG
HC12-3.4-AG
HN12-5.1-AG
HD12-6.8-AG
HE12-10.2-AG
F15-15-AG
HA15-0.9-AG
HB15-1.5-AG
HC15-3-AG
HN15-4.5-AG
HD15-6-AG
HE15-9-AG
F15-15-AG
HA24-0.5-AG
HB24-1.2-AG
HC24-2.4-AG
HN24-3.6-AG
HD24-4.8-AG
HE24-7.2-AG
F24-12-AG
HA24-0.5-AG
HB28-1-AG
HC28-2-AG
HN28-3-AG
HD28-4-AG
HE28-6-AG
F24-12-AG
HB48-0.5-AG
HC48-1-AG
HD48-3-AG
HE48-4-AG
B
B
C
N
D
E
F
F
F
B
B
C
N
D
E
F
B
B
C
N
D
E
F
B
B
C
N
D
E
F
B
B
C
N
D
E
F
B
C
D
E
C
C
C
C
C
C
C
C, D, H
C
C
C
C
C
C, D, H
A
A, C
A, C
A, C
A, C
A, C
A, C, D, H
A, C, D, H
A, C, D
Max
Amps
Model Input
100 to 264 VAC
Case
Type
Additional
Features & Notes
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
DCC
E
F
N
Dimensions
(Inches)
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
12 to 15Vout
12
12
12
12
12
12
12
15*
15
15
15
15
15
15*
C
C
C
C
C
C, D, H
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
Dimensions
(Millimeters)
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
24 to 28Vout
24
24
24
24
24
24
24
28*
28
28
28
28
28
28*
C
C
C
C
C
C, D, H
DCC
E
F
N
48Vout
48
48
48
48
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MCD10016 Rev. 1.2, 13-Nov-09
Page 2 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Unsigned output voltages are isolated and can be used as either + or - polarities.
Nominal
Vout*
5V to 15Vout
+5, –5
+5, –5
+5, –5
5, 12 to 15
5, 12 to 15
5, 12 to 15
+12, –5*
+12, –5*
+12, –12
+12, –12
+12, –12
+12, –12
+12, –12*
+12, –15*
+12, –15*
+12, –15*
+12, –15*
+15, –5*
+15, –5*
+15, –12*
+15, –12*
+15, –12*
15, –12*
1.5, 1.5
3, 3
6, 6
2, 0.5
3, 1.25
6, 2.5
1, 0.4
1.7, 0.7
0.4, 0.4
1, 1
1.7, 1.7
3.4, 3.4
5, 5
1, 0.8
1.7, 1.5
3.4, 3
5, 5
0.8, 0.4
1.5, 0.7
0.8, 1
1.5, 1.7
3, 3.4
5, 5
HAA5-1.5/OVP-AG
HBB5-3/OVP-AG
HCC5-6/OVP-AG
HAA512-AG
HBB512-AG
HCC512-AG
HAA15-0.8-AG
HBB15-1.5-AG
HAD12-0.4-AG
HAA15-0.8-AG
HBB15-1.5-AG
HCC15-3-AG
HDD15-5-AG
HAA15-0.8-AG
HBB15-1.5-AG
HCC15-3-AG
HDD15-5-AG
HAA15-0.8-AG
HBB15-1.5-AG
HAA15-0.8-AG
HBB15-1.5-AG
HCC15-3-AG
HDD15-5-AG
AA
BB
CC
AA
BB
CC
AA
BB
B
AA
BB
CC
E
AA
BB
CC
E
AA
BB
AA
BB
CC
E
A
A
A, C
A
A, C
A, C
C
C
B
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Max
Amps
Model Input
100 to 264 VAC
Case
Type
Additional
Features & Notes
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
DCC
E
F
N
Dimensions
(Inches)
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
DCC
E
F
N
Dimensions
(Millimeters)
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
15V to 24Vout
+15, –15
+15, –15
+15, –15*
+15, –15*
+15, –15
+24, –24
+24, –24
+24, –24
0.4, 0.4
0.8, 0.8
1.5, 1.5
3, 3
5, 5
0.6, 0.6
1.2, 1.2
2.4, 2.4
HAD15-0.4-AG
HAA15-0.8-AG
HBB15-1.5-AG
HCC15-3-AG
HDD15-5-AG
HAA24-0.6-AG
HBB24-1.2-AG
HCC24-2.4-AG
B
AA
BB
CC
E
AA
BB
CC
C
B
C
C
C
C
* May require jumpering or potentiometer adjustment.
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
MCD10016 Rev. 1.2, 13-Nov-09
Page 3 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Unsigned output voltages are isolated and can be used as either + or - polarities.
Nominal
Vout*
+5, +12, –5*
5, +12, –5*
+5, +12, –5*
5, +12, –5*
5, +12, –5*
5, +12, –5*
5, +12, –12
5, +12, –12
+5, +12, –12
5, +12, –12
5, +12, –12
5, +12, –12
5, +12, –12
5, +12, –15*
5, +12, –15*
+5, +12, –15*
5, +12, –15
5, +12, –15
5, +12, –15*
5, +12, –15
5, +15, –5*
5, +15, –5*
+5, +15, –5*
5, +15, –5*
5, +15, –5*
5, +15, –5*
5, +15, –12*
5, +15, –12*
+5, +15, –12*
5, +15, –12
5, +15, –12
5, +15, –12*
5, +15, –12
5, +15, –15*
5, +15, –15*
+5, +15, –15*
5, +15, –15
5, +15, –15
5, +15, –15*
5, +15, –15
Max
Amps
2, 0.4, 0.4
3, 1, 0.4
6, 1, 0.4
6, 1.7, 0.7
8, 1.7, 0.7
12, 1.7, 0.7
2, 0.4, 0.4
3, 1, 1
6, 1, 1
6, 1.7, 1.7
8, 1.7, 1.7
12, 1.7, 1.7
12, 3.4, 3.4
2, 0.4, 0.4
3, 1, 0.8
6, 1, 1
6, 1.7, 1.5
8, 1.7, 1.5
12, 1.7, 1.5
12, 3.4, 3
2, 0.4, 0.4
3, 0.8, 0.4
6, 1, 0.4
6, 1.5, 0.7
8, 1.5, 0.7
12, 1.5, 0.7
2, 0.4, 0.4
3, 0.8, 1
6, 1, 1
6, 1.5, 1.7
8, 1.5, 1.7
12, 1.5, 1.7
12, 3, 3.4
2, 0.4, 0.4
3, 0.8, 0.8
6, 1, 1
6, 1.5, 1.5
8, 1.5, 1.5
12, 1.5, 1.5
12, 3, 3
Model Input
100 to 264 VAC
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HDCC-150W-AG
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HDCC-150W-AG
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HDCC-150W-AG
HTAA-16W-AG
HBAA-40W-AG
HCAA-60W-AG
HCBB-75W-AG
CP131-AG
HDBB-105W-AG
HDCC-150W-AG
Case
Type
AA
BAA
D
CBB
CP131
DBB
AA
BAA
D
CBB
CP131
DBB
DCC
AA
BAA
D
CBB
CP131
DBB
DCC
AA
BAA
D
CBB
CP131
DBB
AA
BAA
D
CBB
CP131
DBB
DCC
AA
BAA
D
CBB
CP131
DBB
DCC
Additional
Features & Notes
A
A, C
A, C
C
A, C
A, C
A
A, C
A, C
C
A, C
C
A, C
A
A, C
A, C
C
A, C
C
A, C
A
A, C
A, C
C
A,
C
A
A, C
A, C
C
A, C
C
A, C
A
A, C
A, C
C
A, C
C
A, C
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
DCC
E
F
N
Dimensions
(Inches)
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
Triple Output Models, 5V to 24Vout
Case
Type
AA
B
BAA
BB
C
CBB
CC
CP131
D
DBB
DCC
E
F
N
Dimensions
(Millimeters)
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
* May require jumpering or potentiometer adjustment.
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
MCD10016 Rev. 1.2, 13-Nov-09
Page 4 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
(Note 1, 2)
Input Frequency
Line Regulation
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
AC input.
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
87
104
191
209
47
-0.01
-1.0
-0.5
-0.05
100
120
220
240
110
132
242
264
63
+0.01
+1.0
+0.5
+0.05
VAC
Hz
%
NOTES:
1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Minimum output adjustment range (Note 1).
-5
+5
%
5 volt outputs.
45
12 volt and 15 volt outputs.
55
%
24 volt and higher outputs.
60
F case models.
3.0
mV
PK-PK
Ripple and Noise
5 volt, 12 volt, and 15 volt models.
5.0
mV
PK-PK
(Note 2)
All three terminal regulator outputs.
0.2
%
PK-PK
24 volt through 250 volt models.
3.0mV
PK-PK
plus 0.02% of output voltage, max
Load Regulation
Output change for a 50% load change: F case models.
-0.02
+0.02
HAD12, HAD15.
-1
+1
%
Outputs with adjustable three terminal regulators.
-0.5
+0.5
All other models.
-0.05
+0.05
Transient Response
Recovery time, to within 1% of initial set point due to a 50% load change.
50
μ
s
NOTES:
1)
OUTPUT VOLTAGE ADJUSTMENTS:
Output voltage adjustments can be made to within
±5% of factory setting of nominal output voltage. Locate the “Vadj”
potentiometer on the
power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not
adjustable.
2) Full load, 20MHz bandwidth.
Output Adjustment
Efficiency
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Leakage Current
UL60950-1.
CSA 60950-1 “cUL”.
EN60950-1.
IEC60950-1.
Input to output.
Input to ground.
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Per EN60950
Approved
3000
1500
VAC
Compatible with system compliance to Level B.
(264VAC)
23
50
μA
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
Automatic current limit/foldback. Rated as a percentage of output power.
5.8
6.6
250
V
mV
%
115
120
140
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
MCD10016 Rev. 1.2, 13-Nov-09
Page 5 of 9