Fully protected against output overload and short circuit.
OCP is installed PCT (Peak Current Timer) for large
peak current. The PSU will shutdown after OCP is
activated in a certain period. The PSU will hiccup
if the output is in short circuit.
Consult the factory for OCP setting.
GENERAL SPECIFICATION
Efficiency:
Typ. 85-89%.(various with output voltage)
Switching Frequency:
Typ. 60KHz.
Circuit Topology:
Fixed Frequency flyback circuit.
Transient Response:
Output voltage returns in less than
2mS following a 25% load change.
Safety Standard:
Meet EN60950-1/ UL60950-1,
Class I for DT7L and Class II for DT8.
Power Density:
5.15-6.5Watts. / Cubic Inch.
Operating Temperature:
0 to +25/+35/+40 °C
without derating.(various with output voltage)
Storage Temperature:
-20 to +85 °C.
Temperature Coefficient:
0.01%/°C
Cooling:
Free air convection.
Construction:
Impact resistant thermo-plastic
enclosure case.
Desktop Format.
Note: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current.
(4) The typical cord is UL1185 AWG#18 or UL1571 16AWG#. The typical cord length for UL1185/AWG#18 is 2ft and for UL1571 16AWG# is 1M.
(5)The DC COM of output is connected with GND
(5) Due to requests in market and advances in technology, specifications subject to change without notice.