AUTO-RANGING AC INPUT AC-DC MULTIPLE OUTPUT
200 WATTS 19" COMPATIBLE DOUBLE EUROCARD
SWITCHING POWER SUPPLIES HSU200 SERIES
FEATURES:
AUTO-RANGING AC INPUT
19" COMPATIBLE EUROCARD FORMAT
MEET THE SAFETY STANDARDS
EMI MEET CISPR PUB.22 & FCC CLASS A
CE MARKING COMPLIANCE
12HP X 6U X160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Auto-ranging 115Vac(90-132Vac) and
230Vac(180-264Vac).
Transient threshold typ. 150Vac.
Input Connector:
DIN 41612 at rear.
Input Frequency:
47-63Hz
Inrush Current:
Typ. 65.0A @ 230Vac.
Input Current:
Typ. 3.3A/115Vac & 1.6A/230Vac.
Dielectric Withstand:
Meet IEC950.
EMI:
Meet CISPR PUB.22 or FCC Class A.
Hold-up Time:
Typ. 26mS.
Power OK:
Installed
Remote Inhibit:
Installed.
Over Temp. Protection (OTP):
Installed (Thermostate).
Power-On LED:
Installed.
Earth leakage:
Typ. 0.3 mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typ. 200 Watts.
Output Connector:
DIN 41612 at rear.
Line Regulation:
Typ. 0.2%.
Load Regulation:
Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±1-2.0%(MA).
Aux. VO3 typ. ±2-3.0%(PR).
Aux. VO4 typ. ±2-3.0%(PR).
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Available at main VO1 & Aux.VO2.(latch).
Adjustability:
Available at VO1 & VO2.
Remote Sense:
Installed at main VO1.
Overload Protection (OLP):
Fully protected against
output overload and short circuit. Typ. 130% full load.
Consult the factory for OLP setting.
Output LED Indicators:
Installed for all outputs.
Operating Temperature:
0 to +50°C at full load.
Derate linearly to +70°C at half load.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. 0.04%/°C.
Cooling:
Free air convection.
Construction format:
12HPx6U compatible double
Eurocard VMEbus standard.
GENERAL SPECIFICATION
Efficiency:
Typ. 76-77.0%.
Switching Frequency:
Typ. 100K Hz.
Circuit Topology:
Forward circuit.
Transient Response:
Output voltage returns in less than
1.5mS following a 25% load change.
Safety Standard:
IEC950/UL1950 Class I.
Power Density:
1.30 Watt / Cubic Inch.
Note: All measurements are at nominal input, full load, and +25°C unless otherwise specified.
OUTPUT VOLTAGE/CURRENT RATINGS CHART
TRIPLE OUTPUT
MODEL NO.
HSU200-T050II
(HSU200-32)
MAIN VO1 @#
Typ.
Volt.
20.0A
20.0A
20.0A
25.0A
5.0V
5.0V
5.0V
3.3V
AUX. VO2 @▲
Typ.
Volt.
7.0A
3.5A
18.0A
17.0A
12.0V
24.0V
3.3V
5.0V
AUX. VO3
●
Typ.
Volt.
1.0A
1.0A
1.0A
1.0A
12.0V
12.0V
12.0V
12.0V
AUX. VO4
●
Typ.
Volt.
1.0A
1.0A
1.0A
1.0A
+12.0V
+12.0V
+12.0V
+12.0V
HSU200-T050MI
(HSU200-33)
HSU200-T050DI
HSU200-T033EI
QUAD OUTPUT
MODEL NO.
HSU200-Q050III
(HSU200-40)
MAIN VO1 @#
Typ.
Volt.
20.0A
20.0A
20.0A
25.0A
"@" Adjustable.
AUX. VO2 @▲
Typ.
Volt.
6.0A
3.0A
15.0A
14.0A
+12.0V
+24.0V
+3.3V
+5.0V
AUX. VO3
●
Typ.
Volt.
1.0A
1.0A
1.0A
1.0A
-12.0V
-12.0V
-12.0V
-12.0V
+5.0V
+5.0V
+5.0V
+3.3V
HSU200-Q050MII
(HSU200-42)
HSU200-Q050DII
HSU200-Q033EII
Symbol:
" " OVP built-in.
"#" Remote sensing.
"▲" Magnetic Amplifier.
"●" Post Regulator.
MECHANICAL DIMENSIONS:
MM [INCHES]
WEIGHT:
2.43Kg (5.35lb.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT
TRIPLE/QUAD OUTPUT
ASSORTED SIGNAL
SYS
LOG. VO1 VO1
Reset
INH. S(+) S(-)
ASSIGNMENT
AC-L AC-N AC-G
HSU200-T
HSU200-Q
+VO1
+VO2
-VO3 +VO4
-
DC COM
P2-18,20,22,24,26
NC
AC
Fail
P1-4
P1-4
P1-10,12,14,16,18
P1-8 P2-14 P2-32 P1-6
20,22,24,26
P1,10-12,24,16,18
P1-28 P1-30 P1-32 P2-4,6,8,10 P2-28,30 P2-16 P2-12 P2-18,20,22,24,26
P1-8 P2-14 P2-32 P1-6
20,22,24,26
P1-28 P1-30 P1-32 P2-4,6,8,10 P2-28,30 P2-16
Mating connector: