IM Series
Signal Relays
AXICOM Signal Relays
108-98001 Rev. M
IM Relay
Disclaimer
While Tyco Electronics and its affiliates referenced herein
have made every reasonable effort to ensure the accuracy
of the information contained in this catalog, Tyco Elec-
tronics cannot assure that this information is error free.
For this reason, Tyco Electronics does not make any re-
presentation or offer any guarantee that such information
is accurate, correct, reliable or current. Tyco Electronics
reserves the right to make any adjustments to the infor-
mation at any time. Tyco Electronics expressly disclaims
any implied warranty regarding the information contained
herein, including, but not limited to, the implied warran-
ties of merchantability or fitness for a particular purpose.
Tyco Electronics‘ only obligations are those stated in Tyco
Electronics’ Standard Terms and Conditions of Sale. Tyco
Electronics will in no case be liable for any incidental, in-
direct or consequential damages arising from or in con-
nection with, including, but not limited to, the sale, resale,
use or misuse of its products. Users should rely on their
own judgment to evaluate the suitability of a product for
a certain purpose and test each product for its intended
application.
In case of any potential ambiguities or questions, please
don’t hesitate to contact us for clarification.
Index
Description
Selection Guide / Relay Code
Coil Data and Ordering Information
- IM
- IM-A
- IM-B
- IM-C
- IM-D
- IM-E
Contact Data
Insulation
General Data
Coil Operating Range
Soldering Condition
Packing
3
4
5
10
12
14
16
18
20
22
23
24
25
26
2 of 28
UL 508
UL 60950
IEC/EN60950
File No. E 111441
IEC Ref. Cert. No. 3270
All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM Signal Relays
108-98001 Rev. M
IM Relay
IM Relay
1 and 2 pole telecom/signal relay, polarized
Through Hole Types (THT), standard version with
5.08 mm, narrow with 3.2 mm between the terminal rows
or Surface Mount Type (SMT)
Relay Types:
non – latching with 1 coil
latching with 1 coil
IM
IM-D
IM-E
IM-C
IM-A
IM-B
Typical Applications
-
-
-
-
-
-
-
Telecommunication
• Access and transmission equipment
• Optical Network Terminals
• Modems
Office and business equipment
Consumer electronics
Measurement and Test equipment
Industrial control
Medical equipment
Automotive applications
Configurations:
2 pole changeover / DPDT / 2 Form C
2 pole break / DPST NC / 2 Form B
2 pole make / DPST NO / 2 Form A
1 pole changeover / SPDT / 1 Form C
1 pole break / SPST NC / 1 Form B
1 pole make / SPST NO / 1 Form A
Versions
-
-
-
High Dielectric Version “C” Type
High Current Version “D” Type
High Contact Resistance Stability Version “P” Type
ROHS compliant (Directive 2002/95/EC) as per product
date code 0438 / Halogen free
Insulation Category
Supplementary insulation according IEC / EN 60950
Working voltage ≤ 300 Vrms
Mains supply voltage ≤ 250 Vrms
Repetitive peak voltage 2500 V
Pollution degree Internal: 1
External: 2
Flammability classification V-0
Maximum operating temperature 85 °C
Meets Australian Requirements between open contacts
Features
-
-
-
-
-
-
-
-
-
-
-
Minimum board-space 60 mm
2
Slim line 10 x 6 mm, 0.39 x 0.24 inch and
Low profile 5.65 mm, 0.222 inch
Switching power 60 W / 62.5 VA
Switching voltage 220 VDC / 250VAC
Switching current 2 / 5 A
Bifurcated contacts
Low coil power consumption
Latching version
• 100 mW
Non latching version
• 140 mW standard
• 100 mW high sensitive version
• 50 mW ultra high sensitive version
High dielectric and surge capability (1.2/50 µs and
10/700 µs) meets Telcordia GR1089, FCC Part 68
and ITU-T K20, K21 and K45 requirements
• up to 2500 Vrms between open contacts
• up to 3000 Vrms between coil and contacts
Meets 1500 Vrms (high dielectric version) between
open contacts as well as Australian clearance
requirements
High mechanical shock resistance up to 300G
functional and 500G survival
All specifications subject to change. Consult Tyco Electronics for latest specifications.
3 of 28
AXICOM Signal Relays
108-98001 Rev. M
IM Relay
Selection Guide
IM Relay
IM-A
1 Pole break
1 Form B
SPST NC
IM-B
1 Pole make
1 Form A
SPST NO
IM-C
1 Pole changeover
1 Form C
SPDT
IM
2 Pole changeover
2 Form C
DPDT
IM-D
2 Pole break
2 Form B
DPST NC
IM-E
2 Pole make
2 Form A
DPST NO
IM-A
High Dielectric “C”
IM-B
High Dielectric “C”
IM-C
Standard
IM
Standard
IM-C
High Dielectric “C”
IM
High Dielectric “C”
IM
High Current “D”
IM
High Contact
Stability “P”
Relay Code
IM
Packing:
Terminal shape:
S = Tube
R = Reel
T = THT-Standard
N = THT-Narrow
J = SMT-J-Leg
G = SMT-Gull Wing
K = THT- Short
Nil = Standard Version
C = High Dielectric Version
D = High Current Version
P = High contact stability Version
see coil data
NIL = 2 pole changeover / DPDT / 2 Form
D=
2 pole break / DPST
E = 2 pole make / DPST NO / 2
A=
B=
C=
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Performance Type:
Coil Version:
Relay Type:
C
NC / 2 Form B
Form A
1 pole break / SPST NC / 1 Form B
1 pole make / SPST NO / 1 Form A
1 pole changeover / SPDT / 1 Form C
4 of 28
AXICOM Signal Relays
108-98001 Rev. M
IM Relay 2 Pole Changeover / 2 Form C / DPDT
Dimensions
IM THT
Standard
L
W
H
T
T1
T2
D1
D2
Tw
S
mm
10.00 ± 0.08
6.00 ± 0.08
5.65 – 0.20
3.2
N/A
5.08 ± 0.10
3.20 ± 0.15
2.20 ± 0.15
0.40
0.75
inch
0.393 ± 0.003
0.236 ± 0.003
0.222 – 0.008
0.125
N/A
0.200 ± 0.004
0.126 ± 0.006
0.087 ± 0.006
0.015
0.029
mm
10.00 ± 0.08
5.70 ± 0.30
5.80 ± 0.08
3.2
N/A
3.20 ± 0.10
3.20 ± 0.15
2.20 ± 0.15
0.4
0.30 ± 0.05
IM THT
Narrow
inch
0.393 ± 0.003
0.224 ± 0.012
0.230 ± 0.003
0.125
N/A
0.126 ± 0.004
0.126 ± 0.006
0.087 ± 0.006
0.015
0.011 ± 0.002
IM SMT
Gull Wings
mm
10.00 ± 0.08
6.00 ± 0.08
5.65 – 0.20
N/A
7.50 ± 0.30
5.08 ± 0.10
3.20 ± 0.15
2.20 ± 0.15
0.4
N/A
inch
0.393 ± 0.003
0.236 ± 0.003
0.222 – 0.008
N/A
0.295 ± 0.011
0.200 ± 0.004
0.126 ± 0.006
0.087 ± 0.006
0.015
N/A
mm
10.00 ± 0.08
6.00 ± 0.08
5.65 – 0.02
N/A
2.80 ± 0.20
5.08 ± 0.10
3.20 ± 0.15
2.20 ± 0.15
0.4
N/A
Dimensions in mm
IM SMT
J-Legs
inch
0.393 ± 0.003
0.236 ± 0.003
0.222 – 0.008
N/A
0.110 ± 0.007
0.200 ± 0.004
0.126 ± 0.006
0.087 ± 0.006
0.015
N/A
THT Version
Standard Version
Narrow Version
SMT Version
Gull Wings
J-Legs
Coplanarity ≤ 0.1mm
Coplanarity ≤ 0.1mm
Mounting Hole Layout
View onto the component side of the PCB (top view)
Solder Pad Layout
View onto the component side of the PCB (top view)
Standard Version
Narrow Version
Gull Wings
Ø min. 0.75
Ø min. 0.75
Terminal Assignment
Relay – top view
Non-Latching Type
not energized condition
Latching Type, 1 Coil
reset condition
Contacts in reset position. Contact
position might change during trans-
portation and must be reset before
use.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
5 of 28