Not for New Designs
IMS-2WWD-40
Vishay Dale
Inductors, Subminiature, Shielded, Axial Leaded
FEATURES
Classification is grade 2, class B
Inductance range is 0.10 μH to 1000 μH
High inductance-to-size ratio
0.133" [3.38 mm] diameter by 0.335" [8.51 mm]
length
• Subminiature shielded inductor
• Solves special problems in density circuit application
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
•
•
•
•
ELECTRICAL SPECIFICATIONS
Inductance Tolerance:
± 10 % on Q-meter
Dielectric Strength:
700 V
RMS
at sea level
Operating Temperature:
-55 °C to +125 °C
Self-Resonant Frequency:
Minimum SRF measured with
full length leads on grid-dip meter
Rating:
Maximum current based on
1
/
3
W dissipation
DENSITY SPECIFICATIONS
Weight:
0.50 g maximum
Shielding:
Less than 3 % coupling with two units mounted
side by side at 1000 cycles
MECHANICAL SPECIFICATIONS
Terminal Strength:
Meets 5 lb pull test
DIMENSIONS
in inches [millimeters]
1.30 [33.02]
Typ. Min.
0.335
[8.51]
Max.
# 24 0.020 ± 0.002
[0.508 ± 0.051]
TCW
0.133 [3.38]
Max.
STANDARD ELECTRICAL SPECIFICATIONS
MODEL
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
Note
(1)
Incremental current: The DC current required to cause a 5 % reduction in the nominal inductance value
For technical questions, contact:
magnetics@vishay.com
1
IND.
(μH)
0.10
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1.0
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
TOL.
(%)
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
Q
MIN.
42
42
42
42
42
42
42
42
41
39
36
35
42
38
38
38
36
38
38
40
42
42
45
47
51
51
TEST FREQUENCY
(MHz)
25
25
25
25
25
25
25
25
25
25
25
25
25
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
2.5
SRF MIN.
(MHz)
> 400
> 400
> 400
366
331
298
288
271
247
236
216
200
136
120
111
103
94
85
78
73
66
62
54
50
44
39
DCR MAX.
()
0.112
0.126
0.138
0.165
0.198
0.220
0.258
0.292
0.360
0.397
0.472
0.638
0.208
0.225
0.265
0.285
0.330
0.381
0.432
0.576
0.787
1.04
1.40
1.68
2.58
3.65
RATED DC
CURRENT
(mA)
1720
1630
1550
1420
1330
1230
1140
1060
960
915
840
720
1260
1210
1120
1080
1000
935
875
755
650
565
485
440
355
300
INCREMENTAL
CURRENT
(mA)
(1)
> 1720
> 1630
> 1550
> 1420
> 1330
> 1230
> 1140
> 1060
> 960
> 915
> 840
> 720
> 1260
> 1210
> 1120
> 1080
> 1000
> 935
> 875
> 755
> 650
> 565
> 485
> 440
> 355
> 300
Document Number: 34047
Revison: 07-Feb-17
www.vishay.com
IRON
PHENOLIC
Not for New Designs
IMS-2WWD-40
www.vishay.com
Vishay Dale
RATED DC
CURRENT
(mA)
620
570
545
510
440
405
370
340
320
305
280
235
215
200
150
140
130
120
100
95
90
85
80
INCREMENTAL
CURRENT
(mA)
(1)
200
175
160
155
150
145
140
130
120
115
100
80
68
64
60
58
56
54
52
50
48
47
45
FERRITE
0
STANDARD ELECTRICAL SPECIFICATIONS
MODEL
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IMS-2WWD-40
IND.
(μH)
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
TOL.
(%)
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
Q
MIN.
45
43
42
37
46
38
42
41
46
46
43
50
49
56
53
57
57
57
50
50
56
49
49
TEST FREQUENCY
(MHz)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
SRF MIN.
(MHz)
44
40
36
33
30
26
23
22
18
17
15
13
12
11
10
9
8.5
8
7
6
5.5
5
4.5
DCR MAX.
()
0.862
1.02
1.12
1.28
1.70
1.99
2.41
2.85
3.21
3.57
4.10
5.97
7.05
8.12
14.8
16.8
18.6
21.1
32.2
36.4
41.1
45.0
52.0
Note
(1)
Incremental current: The DC current required to cause a 5 % reduction in the nominal inductance value
MARKING
- Color coded
ORDERING INFORMATION
IMS-2WWD-40
MODEL
0.10 μH
INDUCTANCE
VALUE
10 %
INDUCTANCE
TOLERANCE
ER
PACKAGE
CODE
e2
JEDEC
®
LEAD (Pb)-FREE
STANDARD
GLOBAL PART NUMBER
I
M
S
0
2
W
W
D
E
R
R
1
0
K
INDUCTANCE
TOLERANCE
4
MODEL
PACKAGE
CODE
INDUCTANCE
VALUE
SERIES
Revison: 07-Feb-17
Document Number: 34047
2
For technical questions, contact:
magnetics@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Revision: 13-Jun-16
1
Document Number: 91000