IRQ-24/4.2-T110N-C

隔离式DC/DC转换器 24V/4.2A 57.6-160Vin Isolated 1/4Brick

器件类别:电源    DC/DC转换器    隔离式DC/DC转换器   

厂商名称:Murata Power Solutions

器件标准:

下载文档
器件参数
参数名称
属性值
厂商名称
Murata Power Solutions
产品种类
隔离式DC/DC转换器
输出端数量
1 Output
输出功率
100 W
输入电压
57.6 V to 160 V
输出电压—通道1
24 V
输出电流—通道1
4.2 A
绝缘电压
3 kVDC
安装风格
Through Hole
长度
2.28 in
宽度
1.45 in
高度
0.5 in
产品
Isolated
系列
IRQ
尺寸
57.9 mm x 36.8 mm x 12.7 mm
工作温度范围
- 40 C to + 85 C
封装
Tray
输入电压(最大值)
160 VDC
输入电压(最小值)
57.6 VDC
输入电压(标称值)
110 VDC
最大工作温度
+ 85 C
机械形式
Isolated
最小工作温度
- 40 C
输出电压V1(标称值)
24 VDC
工厂包装数量
30
文档预览
IRQ Series
Encapsulated Quarter-Brick 100-Watt Isolated DC-DC Converter
Output Voltage (V)
5
12
24
Output Current (A)
20
8.3
4.2
Input Voltage (V)
110
110
110
Optimized for harsh environments in industrial/railway applications, the IRQ
DC-DC converter series offer regulated outputs in an industry-standard
quarter brick fully encased package.
FEATURES
DC input range: 57.6-160V
(Covers both 96V and 110V input range)
Encapsulated circuitry for optimal thermal/vibration
performance
Regulation: ±0.3% from no load to full load
High Efficiency
Maximum baseplate operating temperature: 110ºC,
full load
Over-current & Over-temperature protection
Synchronous rectifier topology
Stable no-load operation
Support Pre-Bias startup
PRODUCT OVERVIEW
The IRQ series regulated converter module
deliver a 5V, 12V or 24V output @ Vin = 57.6
– 160 Vdc in an industry standard quarter
brick fully encased package at astonishing
efficiency. The fully isolated (3000Vdc) IRQ
series accept a 57.6 to 160 Volt DC input
voltage range with a reinforced insulation
system. Typical applications include
industrial, railway and transportation
applications.
The IRQ’s synchronous-rectifier topology and
fixed frequency operations means excellent
efficiencies. A wealth of electronic protection
features include input under voltage lockout,
over voltage lockout protection, output
current limit, current sharing, short circuit
hiccup, Vout overshoot, and over temperature
shutdown.
Available options include various pin lengths
and flanged baseplate. The IRQ series is
designed to meet all UL and IEC emissions,
safety, and flammability certifications.
SAFETY FEATURES
Reinforced insulation
3000Vdc input to output isolation
EN 50155
UL 60950-1 (Pending)
CAN/CSA-C22.2 No. 60950-1 (Pending)
EN 60950-1
RoHS compliant
Slotted / Flanged Baseplate
“V” Option Pins / Pinout
Pin Dia : 0.080
Slotted / Flanged Baseplate
DOSA Pins / Pinout
Pin Dia : 0.040 / 0.060
Standard Baseplate
DOSA Pins / Pinout
Pin Dia : 0.040 / 0.060
For full details go to
ww w.murata-ps.com/rohs
www.murata-ps.com/support
SDC_IRQ_A01.D06 Page 1
of
28
IRQ Series
Encapsulated 100-Watt Isolated DC-DC Converter
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
① ②
Output
Root Model
VOUT IOUT
(V) (A, max)
Total
Power
(W)
100
100
100
Ripple & Noise
(mVp-p)
Typ.
IRQ-5/20-T110
IRQ-12/8.3-T110
IRQ-24/4.2-T110
5
12
24
20
8.3
4.2
80
50
100
Max.
150
120
240
Regulation (max.)
Line
±0.2%
±0.6%
±0.3%
Load
±0.3%
±0.5%
±0.3%
110
110
110
57.6-160
57.6-160
57.6-160
150
50
20
2.06
2.50
2.50
Input
Efficiency
VIN Nom.
(V)
Range
(V)
IIN, no load
(mA)
IIN, full load
(A)
Min.
83.0%
87.0%
86.5%
Typ.
85.5%
87.4%
88.2%
Please refer to the part number structure for additional options and complete ordering part numbers.
All specifications are at nominal line voltage and full load, +25 ºC. Unless otherwise noted. See detailed specifications. Output capacitors are 1 μF ceramic in parallel with 10 μF
electrolytic. I/O caps are necessary for our test equipment and may not be needed for your application.
Part Number Structure
Note: Please see mechanical drawings for details. Special order applies to Positive Logic version. Some model number combinations may not be
available. See website or contact your local Murata sales representative.
www.murata-ps.com/support
SDC_IRQ.A01.D06
Page
2
of
28
IRQ Series
Encapsulated 100-Watt Isolated DC-DC Converter
IRQ SERIES FUNCTIONAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
100 mS max. duration
Input to output
Isolation Voltage
Input to Baseplate
Output to Baseplate
On/Off Remote Control
Operating Temperature Range
Storage Temperature Range
Referred to -Vin
Ambient Temperature
Baseplate Temperature
0
-40
-55
Conditions
Minimum
0
Typical/Nominal
Maximum
160
170
3000
1500
500
15
85
125
Units
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
°C
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied nor recommended.
INPUT
Operating Input Voltage Range
Turn-on Voltage Threshold
Turn-off Voltage Threshold
Lockout Voltage Hysteresis
Recommended External Input
Capacitance
0
52
50
54.5
52
TBD
TBD
160
57
56
Vdc
Vdc
Vdc
Vdc
uF
FEATURES and OPTIONS
Conditions
Minimum
Typical/Nominal
Maximum
Units
Primary On/Off control (designed to be driving with an open collector logic, Voltages referenced to -Vin)
“P” suffix:
Positive Logic, ON state
Positive Logic, OFF state
Control Current
“N” suffix:
Negative Logic, ON state
Negative Logic, OFF state
Control Current
Remote Sense Compliance
ON = ground pin or external voltage
OFF = pin open or external voltage
open collector/drain
Sense pins connected externally to
respective Vout pins
-0.1
2.5
1
5
0.8
15
2
V
V
mA
%
ON = pin open or external voltage
OFF = ground pin or external voltage
open collector/drain
3.5
0
1
15
1
2
V
V
mA
ENVIRONMENTAL
Operating Ambient Temperature
Ambient Temperature
Baseplate Temperature
Storage Temperature
Semiconductor Junction Temperature
Thermal Protection
Thermal Protection Restart Hysteresis
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
External filter required; see
Emissions performance test.
B
RoHS-6
Average PCB Temperature
125
-40
-40
-55
85
110
125
125
°C
°C
°C
°C
°C
°C
Class
www.murata-ps.com/support
SDC_IRQ.A01.D06
Page
3
of
28
IRQ Series
Encapsulated 100-Watt Isolated DC-DC Converter
IRQ SERIES FUNCTIONAL SPECIFICATIONS
GENERAL and SAFETY
Insulation Safety Rating
Isolation Resistance
Isolation Capacitance
Safety
Certified to UL-60950-1, CSA-C22.2
No.60950-1, IEC/EN60950-1, 2nd edition
(pending)
Yes
10
500
Reinforced
pF
MECHANICAL
Through Hole Pin Diameter
Conditions
Minimum
Typical/Nominal
0.06 & 0.04
1.524 & 1.016
Maximum
Units
Inches
mm
Inches
mm
Standard:Option#2
Option#1
0.08
2.032
Through Hole Pin Material
TH Pin Plating Metal and Thickness
Nickel subplate
Gold overplate
Copper alloy
98.4-299
4.7-19.6
µ-inches
µ-inches
www.murata-ps.com/support
SDC_IRQ.A01.D06
Page
4
of
28
IRQ Series
Encapsulated 100-Watt Isolated DC-DC Converter
FUNCTIONAL SPECIFICATIONS (IRQ-5/20-T110)
INPUT
Input current
Full Load Conditions
Low Line input current
Inrush Transient
Short Circuit input current
No Load input current
Shut-Down input current (Off, UV,
OT)
Back Ripple Current
Measured at the input of module with a
simulated source impedance of 12µH,
220µF, 450V, across source, 33µF, 250V
external capacitors across input pins.
Pi
5
A
Iout = minimum, unit=ON
Vin = nominal
Vin = minimum
Vin = 110v
1.06
2.01
0.1
0.1
50
15
1.11
2.06
0.2
0.2
150
30
A
A
A
2
-Sec.
A
mA
mA
Conditions
Minimum
Typical/Nominal
Maximum
Units
2000
mAp-p
Internal Filter Type/Value
Recommended Input fuse
OUTPUT
Total Output Power
Voltage
Setting Accuracy
Output Adjust Range
Overvoltage Protection
Current
Output Current Range
Minimum Load
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Temperature Coefficient
Maximum Output Capacitance
Vin = 57.6-160, Vout = nom., full load
Iout = min. to max., Vin = nom.
20 MHz BW, Cout = 1µF
paralleled with 10µF
At all outputs
(Loads : CR mode)
(Loads : CC mode)
80
0.02
3300
3300
±0.2
±0.3
150
%
%
mV pk-pk
% of Vnom./°C
μF
μF
Hiccup technique - Auto recovery within
1.25% of Vout
Output shorted to ground, no damage
Hiccup current limiting
2.0
Continuous
Non-latching
4.0
A
cold condition
22
0
20
0
25
30
A
20
A
At 100% load, no trim, all conditions
4.95
4.950
6
6.3
5
5.05
5.050
6.5
Vdc
Vdc
Vdc
0
100
101
W
GENERAL and SAFETY
Efficiency
Vin=110V, full load
83
85.5
%
www.murata-ps.com/support
SDC_IRQ.A01.D06
Page
5
of
28
查看更多>
热门器件
热门资源推荐
器件捷径:
L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 LA LB LC LD LE LF LG LH LI LJ LK LL LM LN LO LP LQ LR LS LT LU LV LW LX LY LZ M0 M1 M2 M3 M4 M5 M6 M7 M8 M9 MA MB MC MD ME MF MG MH MI MJ MK ML MM MN MO MP MQ MR MS MT MU MV MW MX MY MZ N0 N1 N2 N3 N4 N5 N6 N7 N8 NA NB NC ND NE NF NG NH NI NJ NK NL NM NN NO NP NQ NR NS NT NU NV NX NZ O0 O1 O2 O3 OA OB OC OD OE OF OG OH OI OJ OK OL OM ON OP OQ OR OS OT OV OX OY OZ P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 PA PB PC PD PE PF PG PH PI PJ PK PL PM PN PO PP PQ PR PS PT PU PV PW PX PY PZ Q1 Q2 Q3 Q4 Q5 Q6 Q8 Q9 QA QB QC QE QF QG QH QK QL QM QP QR QS QT QV QW QX QY R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 RA RB RC RD RE RF RG RH RI RJ RK RL RM RN RO RP RQ RR RS RT RU RV RW RX RY RZ