ss
w
Embedded Power for
Business-Critical Continuity
Intelligent VS Power
Up to 4920 Watts
Font: Minion Bold for VS
Minion italic for i ; size for each is the same
Created on Mac
TM
Rev. 7.9.09_145
iVS Series
1 of 11
Color: "i" 100% Blue, 50% Magenta,
0% Yellow, 0% Black
"VS" - 100% Black
Total Power:
Up to 4920 Watts
Input Voltage:
85 - 264 Vdc
120 - 300 Vdc
# of Outputs:
Up to 24
Special Features
• Full medical EN60601 approval
• Intelligent I
2
C control
• Voltage adjustment on all outputs
(manual or I
2
C)
• Configurable input and output
OK signals and indicators
• Configurable inhibit/enable
• Configurable output UP/DOWN
sequencing
• High power density (12 W/cu-in)
• Intelligent fan (speed control/
fault status)
• uP controlled PFC input with
active Inrush protection
• I
2
C monitor of voltage, current,
and temperature
• Programmable voltage, current
limit, inhibit/enable through I
2
C
• Optional extended hold-up
module (SEMI F47 compliance)
• Increased power density to 150%
• Optional conformal coating
• Industrial temp range (-40 ºC to
70 ºC)
• Uses standard iMP
modules
• Field upgradeable firmware
• RoHS compliant
Electrical Specifications
Input
Input range:
iVS1 & iVS3
90 - 264 Vac 1Ø; 120 - 300 Vdc
iVS6 & iVS8
170 - 264 Vac 3Ø
iVS8H
480 Vac nominal 3Ø
380 Vac nominal 3Ø derate to 3800 W max.
Frequency:
47 - 440 Hz
Inrush current:
Efficiency:
Power Factor:
Turn-on time:
EMI Filter:
Leakage current:
Radiated EMI:
Holdover storage:
40 A peak maximum (soft start)
Up to 85% @ full case load
0.99 typ. meets EN61000-3-2
AC on 1.5 sec typical, inhibit/enable 150ms typical Programmable;
50ms internal turn-on delay (Dual Output only)
CISPR 22/EN55022 Level “B”
500 µA max. @ 240 Vac; 47-63 Hz
CISPR 22/EN55022 Level “B”
10 ms minimum (independent of input Vac) additional 20mSEC
holdover storage with optional HUP module
(SEMI F47 compatible)
>5ms early warning minutes before outputs lose regulation Full cycle
ride thru (50 Hz). Programmable
Meets EN61000-3-2
Meets EN60950 and EN60601
3 years
AC OK:
Harmonic distortion:
Isolation:
Warranty:
Global inhibit / enable: TTL, Logic “1” and Logic “0”; configurable
Safety
UL
CSA
VDE
BABT
• CB
• CE
•
•
•
•
UL60950/UL2601
CSA22.2 No. 234 Level 5
EN60950/EN60601-1
Compliance to EN 60950/
EN60601 BS 7002
Certificate and report
Mark to LVD
w
Embedded Power for
Business-Critical Continuity
Output
Adjustment range:*
Factory set point accuracy:
I
2
C output program accuracy:
Margining:
Overall regulation:
Ripple:
± 10% minimum all outputs (manual)
(full module adjustment range using I
2
C)
1%
±
5%
± 4 - 6% nominal analog (single output module only)
0.4% or 20 mV max. (1500 W modules 1% max.)
RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater
Bandwidth limited to 20 MHz
< 2% or 100 mV, with 25% load step
To within 1% in < 300 µsec
Configurable through I
2
C (calibration required). Single output module and
main output of the dual output module 105-120% of rated output current.
Aux output of dual output module 105-140% of rated output current.
Special programmable OCP delay on 1500 W module from 100 mSec to
25.5 seconds with shutdown features.
Protected for continuous short-circuit.
Recovery is automatic upon removal of short
(Shutdown mode on 1500 W module).
Configurable through I
2
C
2 - 5.5 V 122 - 134% ; 6 - 60 V 110 - 120%
2 - 6 V 122 - 134% ; 8 - 28 V 110 - 120%
No overvoltage protection provided
Configurable through I
2
C
All outputs disabled when internal temp exceeds safe operating range. >
5ms warning (AC OK signal) before shutdown
Up to 0.5 V total drop (not available on triple output module)
Current share to within 2% of total rated current
Rev. 7.9.09_145
iVS Series
of 11
Dynamic response:
Recovery time:
Overcurrent protection:**
Short-circuit protection:
Overvoltage protection:*
Single output module:
Dual output module:
Triple output module:
Thermal protection:*
Remote sense:
Single wire parallel:
DC OK:*
+/-5% of nominal. onfigurable through I
2
C
C
Minimum load:
Not required
Housekeeping bias voltage:
5 Vdc @1.0 A max. present whenever AC input is applied
Module inhibit:*
Configured and controlled through I
2
C
Output/Output isolation:
> 1 Megohm, 500 V
2
* Can be controlled via I
C
** Controlled via I
2
C but requires load calibration (except 1500 W module)
Environmental Specifications
Operating temperature:
-40 ° to 70 °C ambient. Derate each output 2.5% per degree from 50 ° to 70 °C.
( -20 °C start up)
Storage temperature:
-40 °C to 85 °C
Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Vibration:
MTBF demonstrated:
Operating; non-condensing 10% to 95% RH
IEC68-2-6 to the levels of IEC721-3-2
> 550,000 hours at full load, 220 Vac and 25 °C ambient conditions
Embedded Power for
Business-Critical Continuity
Output Module Line-up
Module Code
Module Type
Max output power
Max output current
Output voltages available*
Standard voltage increments
Remote sense
Remote margin
V-Program - I
2
C Control
Active Current Share
Module Inhibit - I
2
C Control
Module Inhibit - Analog
Overvoltage/Overcurrent
protection
Minimum load required
Slots occupied in any
iVS
case
1
Single
210 W
35 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
1
2
Single
360 W
60 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
2
3
Single
750 W
150 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
3
5
Single
1500 W
140 A
6-60 V
18
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
4
Yes
No
Yes
Yes
Yes
Yes
Yes
No
1
4
Dual
144 W
10 A
—
Triple
36 W
2A
Rev. 7.9.09_145
iVS Series
of 11
8 - 15*, 24 - 28; 8 - 15*, 8 - 15*; 8
8-15, 8-15, 2-6; 8-15, 8-15, 8-15; 8-
- 15*, 2 - 6; 2 - 6, 2 - 6; 24 - 28, 24 - 28; 15, 8-15, 18-28; 8-15, 18-28, 2-6
24 - 28, 2 - 6
16
Yes
No
Yes
No
Yes
No
Yes
No
18
No
No
No
No
Yes
No
Yes
No
1
* Note: Contact Factory for extended range down to 6 V
Single
Output Module Voltage/Current*
Voltage
Voltage
Code
Single Output Module Code
Dual Output***
Triple Output
1
2 V
2.2 V
3 V
3.3 V
5 V
5.2 V
5.5 V
6.0 V
8.0 V
10 V
11 V
12 V
14 V
15 V
18 V
20 V
24 V
28 V
30 V
33 V
36 V
42 V
48 V
54 V
60 V
Special*
Special*
Special*
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Z
Z
35 A
35 A
35 A
35 A
35 A
35 A
34 A
23 A
20 A
18 A
17 A
17 A
14 A
14 A
11 A
10.5 A
8.5 A
6.7 A
6.5 A
6.2 A
5.8 A
4.2 A
4.0 A
3.7 A
3.5 A
35 A
35 A
20 A
2
3
5
4
4
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A*
4A
4A
4A
4A
4A
4A
—
—
2A
2A
—
—
—
—
—
—
—
10 A
10 A
8A
-
—
—
—
—
—
—
—
—
1 A
1 A
1 A
1 A
1 A
1 A
—
—
—
—
—
—
—
—
—
—
—
-
—
—
—
—
—
—
—
—
1 A
1 A
1 A
1 A
1 A
1 A
0.5 A
0.5 A
0.5 A
0.5 A
—
—
—
—
—
—
—
-
2A
2A
2A
2A
2A
2A
2A
2A
1 A
1 A
1 A
1 A
1 A
1 A
0.5 A
0.5 A
0.5 A
0.5 A
—
—
—
—
—
—
—
I
2
C
Adjustment
Ranges****
210 W
750 W
360 W
1500 W
Dual
Triple
60 A
150 A
—
10 A
60 A
150 A
—
10 A
60 A
150 A
—
10 A
60 A
150 A
—
10 A
60 A
150 A
—
10 A
60 A
144 A
—
10 A
58 A
136 A
—
10 A
42 A
97.5 A 140 A 10 A*
36 A
84.4 A
140 A 10 A
32 A
75 A
140 A 10 A
31 A
68 A 136.3 A 10 A
30 A 62.5 A 125 A 10 A
21 A 53.5 A 107 A
9 A
100 A
8 A
20 A
50 A
19 A 41.6 A 83.3 A
—
18 A 37.5 A 75 A
—
15 A
30 A 62.5 A
4 A
11 A 26.8 A 53.5 A 3 A
50 A
—
11 A
25 A
10.9 A 22.7 A 35.8 A
—
10 A
20.8 A
35.8 A
—
7.5 A
16 A 35.7 A
—
7.5 A 15.6 A 31.2 A
—
6.0 A 13.9 A 27.7 A
—
6.0 A 12.5 A 25 A
—
60 A
60 A
36 A
150 A
150 A
80 A
—
—
140 A
—
—
—
1.8 - 2.2
2.0 - 2.4
2.7 - 3.3
3.0 - 3.6
4.5 - 5.5
4.7 - 5.7
5.0 - 6.1
5.4 - 6.6
7.2 - 8.8
9.0 - 11.0
9.9 - 12.1
10.8 - 13.2
12.6 - 15.4
13.5 - 16.5
16.2 - 19.8
18.0 - 22.0
21.6 - 26.4
25.2 - 30.8
27.0 - 33.0
29.7 - 36.3
32.4 - 39.6
37.8 - 46.2
43.2 - 52.8
48.6 - 59.4
54.0 - 66.0
2.3 - 2.6
3.7 - 4.4
6.7 - 7.1
Contact Factory
144 W
36 W
* Note: Contact Factory for extended range down to 6 V.
**Increments of current not shown can be achieved by paralleling modules (add currents of each module selected).
*** Total output power on dual model must not exceed 144 W.
**** For single output modules only.
w
Embedded Power for
Business-Critical Continuity
Ordering Information
Case Size
Sample below is 3210 W case with 12 V @ 125 A; 24 V @ 8.5 A; 5 V @ 60 A; 12 V @ 10 A and 12 V @ 4 A; with no options.
Module/Voltage/Option Codes
First - Module Code
Second - Voltage Code
Third - Option Code
Rev. 7.9.09_145
iVS Series
4 of 11
Case Option Codes
Software Code
Hardware Code
iVS1
Case Size (mm)
1-Phase Input
1 = 5” x 5” x 11”; 1500 W - 3210 W, 9 Slots
(127 x 127 x 279.4)
3 = 5” x 8” x 11”; 1800 W - 4500 W, 14 Slots
(127 x 203.2 x 279.4)
3-Phase Input
6 = 5” x 5” x 11”; 3120 W, 9 Slots
(127 x 127 x 279.4)
8 = 5” x 8” x 11”; 4920 W, 14 Slots
(127 x 203.2 x 279.4)
8H = 5” x 8” x 11”; 4920 W, 14 Slots
(127 x 203.2 x 279.4)
-
5L1
-
1Q1
-
2EO
-
4LL0
-
Module Codes
Module/voltage/option codes
Module Codes:
(None) = 36 W triple O/P (1 slot)
1 = 210 W single O/P (1 slot)
2 = 360 W single O/P (2 slot)
3 = 750 W single O/P (3 slot)
5 = 1500 W single O/P (slot 4)
4 = 144 W dual O/P (1 slot)
HUP = Extra 30mS hold-up (1 slot)
Voltage Codes:
See Output Module Voltage/Current
table above
Option Codes:
0 = Standard
1 = Module enable
2 = Constant current
3 = 1 & 2 combined
4 = Set for use in standard
(non-intelligent case)
5 = Shutdown mode for 1500 W
6 = 1 & 5 combined
7-9 Future
00
Case Option Codes
First Digit
0 - 9 = Parallel code
(See parallel codes table below)
Second Digit
0 = No options
1 = Reverse air
2 = Not used
3 = Global enable
4 = Fan Off w/inhibit
5 = Opt 1 + Opt 3
6 = Opt 1 + Opt 4
7 = Opt 3 + Opt 4
8 = Opt 1 + 3 + 4
9 = Future
-
A
Software code used
for configuration
change. “A” is
standard
-
###
Factory assembled
for hardware of
firmware mods.
Ordering Note:
1. USB to I
2
C module order code
73-769-001
Parallel
Code
1
2
3
4
Slot No.
Diagram
1 & 2
2 & 3
3 & 4
4 & 5
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
iVS1, 6
Possible Configurations
210 210; 210 144; 144 144
360 360; 360 210; 360 144; + above
750 360; 750 210; 750 144; 210 210;
210 144; 144 144
1500 210; 1500 144; 210 210; 210 144;
144 144; 360 210; 360 144
750 210 210; 750 210 144; 750 144 144
1500 1500; 1500 750
1500 210 210; 1500 210 144; 1500 144
144
750 750
1500 1500; 1500 360; 1500 144
750 210 & 750 210
750, 360, 750
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC
14 13 12 11 10 9
iVS3, 8, 8H
Diagram
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
Possible Configurations
210 210; 210 144; 144 144
360 360; 360 210; 360 144; + above
750 750; 750 360; 750 210; 750 144;
210 210; 210 144; 144 144
1500 1500; 1500 750; 1500 360; 1500 210;
1500 144; 210 210; 210 144; 144 144; 360
360; 360 210; 360 144
750 210 210; 750 210 144; 750 144 144
5
6
7
8
9
A
C
E
F
G
H
3, 4, & 5
4 & 6
4, 5, & 6
iVS1,6: 3 & 6
iVS3,8,8H: 4, 5, & 9
iVS1,6: 1 & 6
iVS3, 8, 8H: 4, 5 & 9; 12 & 13
iVS1,6: 3 & 4; 8 & 9
iVS3, 8, 8H: 4 & 5; 11 & 12
iVS1,6: 3, 4 & 6
iVS3, 8, 8H: 6 & 7; 3, 4, 11 & 12
iVS3, 8, 8H: 3, 4, 11, & 12
iVS3, 8, 8H: 3 & 4; 11 & 12
iVS3, 8, 8H: 3,4 & 9
iVS3, 8, 8H: 11 & 12
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
AC 9 8 7 6
5 4 3 2 1
1500 210 210; 1500 210 144; 1500 144 144
1500 1500 1500; 1500 1500 750; 1500 1500
360; 1500 1500 210; 1500 1500 144
1500 1500 1500 360; 1500 1500 1500 210;
1500 1500 1500 144
1500 1500 & 750 750
750 750 360 750 750
750 750 750 750
750 360 & 750 210; 750 750 & 750 750
750 750 750
750 750
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
AC 14 13 12 11 10 9
8 7 6 5 4 3 2 1
Embedded Power for
Business-Critical Continuity
iVS Case Specifications
iVS1
and
iVS6
S
L
O
T
9
S
L
O
T
5
S
L
O
T
4
S
L
O
T
8
S
L
O
T
3
S
L
O
T
7
S
L
O
T
2
S
L
O
T
6
S
L
O
T
1
Rev. 7.9.09_145
iVS Series
5 of 11
Input
90-264 Vac
170-264 Vac
iVS1 =
5” x 5” x 11”
1500 W max. 3210 W max.
(
127 x 127 x 279.4)
9 available slots
iVS6 =
5” x 5” x 11”
N/A
(
127 x 127 x 279.4)
9 available slots
3-phase only
170-264 Vac
3210 W max.
iVS3, iVS8,
and
iVS8H
S
L
O
T
14
S
L
O
T
8
S
L
O
T
7
S
L
O
T
6
S
L
O
T
13
S
L
O
T
5
S
L
O
T
12
S
L
O
T
4
S
L
O
T
11
S
L
O
T
3
S
L
O
T
10
S
L
O
T
2
S
L
O
T
9
S
L
O
T
1
iVS3
= 5” x 8” x 11”
1800 W max. 4500 W max.
(
127 x 203.2 x 279.4)
14 available slots
iVS8 =
5” x 8” x 11”
N/A
(
127 x 203.2 x 279.4)
1
14 available slots
2
iVS8H =5” x 8” x 11”
N/A
(
127 x 203.2 x 279.4)
3
14 available slots
170-264 Vac
4920 W max.
380 Vac
Input
90-264 Vac
170-264 Vac
N
~
3800 W max.
480 Vac
4920 W max.
Figure 1. AC Input
Pin Connectors
Figure 1.
AC Input
1
2
3
4
L
L
L
AC Input Single Phase
Pin No.
Function
AC neutral
AC line (hot)
1
N
1
2
3
3 Phase
Line 1
φ
1
Line 2
Line 3
Figure 2.
Connector J1
PFC Input Connector (control & signals)
Function
Input AC OK - “emitter”
Input AC OK - “collector”
Global DC OK - “emitter”
Global DC OK - “collector”
No connection
Global inhibit/optional enable logic “0”
Global inhibit/optional enable logic “1”
Global inhibit/optional enable return
+5 VSB housekeeping
+5 VSB housekeeping return
1
2
3
N
~
1
iVS1, iVS3
L
L
iVS6
L
4
2
2
Chassis (earth)
ground
3
3
Chassis (earth)
4
~
φ
2
φ
3
ground
4
3
2
1
iVS8, iVS8H
Pin No.
1
1
5
2
6
10
3
Mates with
Connector J1
Figure 2.
4
Molex 90142-0010 Housing
90119-2110 Pin
5
Connector Kit Part No.:
6
70-841-004
7
8
9
10
I
2
C Bus Output Connector
Figure 3.
Connector J
Mates with
Landwin 2050S1000 housing
2053T011P pin
Connector Kit Part No.:
70-841-023
Pin No.
1
2
3
4
5
6
7
8
9
10
Function
No connection
No connection
No connection
Serial clock signal (SCL)
Serial data signal (SDA)
Address bit 0 (A0)
Address bit 1 (A1)
Address bit 2 (A2)
Secondary return (GND)
5 VCC external bus (5 VCC bus)