首页 > 器件类别 > 电路保护 > 电路保护

L43-B1-42-410-47A-DA

Magnetic Circuit Breaker,

器件类别:电路保护    电路保护   

厂商名称:Carling Technologies

器件标准:

下载文档
器件参数
参数名称
属性值
是否Rohs认证
符合
厂商名称
Carling Technologies
Reach Compliance Code
compli
电路保护类型
MAGNETIC CIRCUIT BREAKER
文档预览
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
2 | L-Series Circuit Breaker - Design Features
L-Series Circuit Breaker
DESIGN FEATURES
1–Pole Configuration
with Low Profile Rocker Actuator
PATENT PENDING FLUSH
ROCKER ACTUATOR
PATENT PENDING
LOW PROFILE
DESIGN: 1.760
INCH (4.4 CM)
INTEGRATED
MOLEX
CONNECTOR
For optional
current
transformer
2–Pole Configuration
with Push-To-Reset Guard
OPTIONAL PUSH-TO-RESET GUARD
INTER-POLE
BARRIER
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
L-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Voltage, Current and IC Ratings
Voltage (VAC)
240
240
120/240
120/240
Notes:
*
Breaking both sides of the line
** 3
rd
pole to be neutral break
Current (A)
0.1 - 32
0.1 - 32
0.1 - 32
0.1 - 32
Number of Poles
1
2*
2
3**
Current Metering
Yes
Yes
Yes
Yes
Interrupt Capacity (Amps)
EN60934
UL489
Icn
Inc
5000
5000
5000
5000
3000
3000
N/A
N/A
10000
10000
N/A
N/A
Time Delay
Delay Curve Number
21
22
24
26
42
44
46
Voltage
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Description
Ultrashort
Short
Medium
Long
Hi-inrush, Short
Hi-inrush, Medium
Hi-inrush, Long
Impedance
Current (amps)
0.1-5.0
5.1-32.0
Tolerance (%)
+/-15
+/-25
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
4 | L-Series Circuit Breaker - General Specifications
Electrical
Current Metering
Integrated current transformer.
Measurement range: 1-32 Amps
Voltage output: 10mV per Amp
according to the formula below:
2(Amp) ≤ I ≤ 32(Amp)
V = 0.01× I ± 2%
V V
10
I I
10
V
10
I
10
Environmental
Environmental
Operating Temp
Vibration
MIL-PRF-55629 and MIL-STD-202G
-40ºC to +85 ºC
Withstands 0.06” excursion from
10-55 Hz and 10Gs 55-500 Hz at
rated current per MIL-PRF-55629
and MIL-STD-202G, Method 204D,
Test Condition A. Instantaneous and
ultra-short curves tested at 90% of
rated current.
Withstands 100 Gs, 6 ms saw tooth
while carrying rated current
per MIL-PRF-55629 and MIL-STD-
202G, Method 213B, Test Condition
“I”. Instantaneous and ultra short
curves tested at 90% of rated
current.
MIL-PRF-55629 and MIL-STD-
202G, Method 107G, Condition A
(5-cycles at -55ºC to +25ºC to
+85ºC to +25ºC).
MIL-PRF-55629 and MIL-STD-
202G, Method 106G, i.e., Ten 24-
hour cycles at +25ºC to +65ºC, 80-
98% RH.
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96hrs)
1-3 poles
Screw Terminals with the following
thread sizes: 10-32, 8-32, M5, M4
Standard for 2 & 3 poles
Threaded Insert: #6-32 UNC-2B, or
M3X0.5-6H B ISO (2 per Pole)
Rocker, with or without guard
Series Trip
Housing - Glass Filled Polyester
Rocker – Nylon 6/6
Line/Load Terminals – Copper Alloy;
Bright Acid Tin Plated
~107 Grams (~3.76 Ounces) per pole
Housing - Black, Rocker - Black
0.85%
Shock
Where V=CT output in volts V10=CT
output in volts with I=I10=10 (A);
I=primary current in amperage (50/60
Hz). Phase shift between primary
current and CT output is 0.25±0.25°.
Maximum crest factor of primary current
is 1.73.
R1 shall be integrated in the breaker.
R2 and R3 are provided by end user
and external to the breaker. Connection:
below Load Terminal. 2-pin connector,
Molex 35362-0250. Mating Connector
housing – Molex PN35507-0200.
Dielectric Strength UL, CSA-1960V
50/60 Hz for one minute between all
electrically isolated terminals.
Comply with the 8mm spacing and
3750V 50/60 Hz dielectric requirements
from hazardous voltage to operator
accessible surfaces and between main
circuits of adjacent poles per
Publications EN 60950 and VDE 0805
I
~
(FROM I THOUGH 32 AMPS)
R2=14Ω±I%
RI=28Ω±I%
V
R3=14Ω±I%
I : 1400
CT
V=0,02 X (
I
)
Thermal Shock
Moisture Resistance
Salt Spray
Physical
Number of Poles
Termination
Termination Barrier
Mounting
Actuator
Internal Circuit Config.
Materials
Insulation Resistance
Overload
Interrupt Capacity
Minimum of 100
Megohms@500VDC
50 operations @ 600% of rated
See Table 1
Weight
Standard Color
Mechanical
Endurance
10,000 “On-Off” Operations @ 6 per
minute; 6000 cycles with rated
Current and Voltage; 4000 cycles
without electrical load.
Trips on overload even when
actuator is forcibly held in the “On”
position.
The operating actuator moves
positively to the “Off” position when
an overload causes the breaker to trip
Trip Free
Trip Indication
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
L-Series Circuit Breaker - Dimensional Specifications in.[mm] | 5
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
查看更多>
数码管资料
数码管资料 数码管资料 ...
zxopenljx EE_FPGA学习乐园
我想用STM32和tft做一个简易的示波器,谁能指导下啊
毕业后,找了个测试工作,觉得没前途,于是想抓紧时间学点别的。本人水平有限,听人说这样很好实现,指标要...
wy_prayer DIY/开源硬件专区
iic通讯,主机接收不到有关数据
问题描述:主从机通讯过程中,触摸屏按下时发送的键值,主机总是无法接收到。抬起时发送的键值能收到。 ...
柯小西 Microchip MCU
中国当代医疗电子的发展如何???
我是一名医学信息工程专业的学生,学习医疗电子,想问问各位前辈这个行业怎么样,发张前景,工资??? 中...
tuibian 医疗电子
关于MOS管衬底-源极电压对UGS(th)的影响
本科生,刚学习模拟电路 教材上(清华大学出版社,童诗白第六版p44)写的衬底源极的P...
冰风F 模拟电子
热门器件
热门资源推荐
器件捷径:
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF EG EH EI EJ EK EL EM EN EO EP EQ ER ES ET EU EV EW EX EY EZ F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF FG FH FI FJ FK FL FM FN FO FP FQ FR FS FT FU FV FW FX FY FZ G0 G1 G2 G3 G4 G5 G6 G7 G8 G9 GA GB GC GD GE GF GG GH GI GJ GK GL GM GN GO GP GQ GR GS GT GU GV GW GX GZ H0 H1 H2 H3 H4 H5 H6 H7 H8 HA HB HC HD HE HF HG HH HI HJ HK HL HM HN HO HP HQ HR HS HT HU HV HW HX HY HZ I1 I2 I3 I4 I5 I6 I7 IA IB IC ID IE IF IG IH II IK IL IM IN IO IP IQ IR IS IT IU IV IW IX J0 J1 J2 J6 J7 JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ JR JS JT JV JW JX JZ K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 KA KB KC KD KE KF KG KH KI KJ KK KL KM KN KO KP KQ KR KS KT KU KV KW KX KY KZ
需要登录后才可以下载。
登录取消