Technical Data Sheet
Cable assembly
Mini Coax Plug/Jack - SMA Plug - RTK 047 Cable
L99-815-XXD
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances: ± 3mm for A
≤
300 mm; ± 1% for A > 300 mm
Available variants
Type
L99-815-XXD
WW – week
Note:
max. Insertion loss at 20 GHz
≤ 0.0050 dB/mm * A mm + 0.60 dB
D=8 Channel
YYYY – year
Marking
ROSENBERGER YYYY-WW
L99-815-XXD
FAC-RRRRRRR
ssss
Weight (g) / pce
0,044 g/mm * A mm + 42.5 g
RRRRRRR – lot nr.
XX – length in cm
A=XX*10
ssss – serial no.
FAC – Factory Code
max. Insertion Loss:
First constant = Cable attenuation in dB /mm; Second Constant = Connector left and Connector right +needed Adaptor
Weight:
First constant = Cable- and Armour- weight per mm; Second Constant = Connector left and Connector right weight per pce
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1/2
Technical Data Sheet
Cable assembly
Mini Coax Plug/Jack - SMA Plug - RTK 047 Cable
L99-815-XXD
Assembly parts
Connector left
Connector left
Connector right
Cable
Housing
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Mini Coax plug
Mini Coax jack
SMA plug
RTK 047
23Z121-005
23S103-270L3
23K103-270L3
32S102-270L5
(8 channel) Luranyl KR 2402 gray
Electrical data
Impedance
Frequency
1
Return loss
1
Insertion loss
Phase matched by pairs
50
Ω
DC to 20 GHz
≥
16 dB, DC to 20 GHz
see table available variants
max. 5ps delay difference
Individual testing:
The S-Parameters (S11; S22; S21; S12) will be tested and the cable pairs are measured for phase matching
1
Return Loss and Insertion Loss includes the measurement adaptor
Mechanical data
Minimum bend radius:
Single
Multiple
5.1 mm
10.2 mm
Environmental data
Temperature range
RoHS
-40°C to +115°C
compliant
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
18.08.14
Approved
A.Schadhauser
Date
20.02.15
Rev.
d00
Engineering change number
15-0004
Name
S. Andorfer
Date
20.02.15
RF_35/09.14/6.2
Martin Moder
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page