LAN9303/LAN9303i
Small Form Factor Three
Port 10/100 Managed
Ethernet Switch with Single
MII/RMII/Turbo MII
PRODUCT FEATURES
Highlights
Up to 200Mbps via Turbo MII Interface
High performance, full featured 3 port switch with
VLAN, QoS packet prioritization, Rate Limiting, IGMP
monitoring and management functions
Serial management via I
2
C or SMI
Unique Virtual PHY feature simplifies software
development by mimicking the multiple switch ports
as a single port PHY
Switch Management
— Port mirroring/monitoring/sniffing: ingress and/or egress
traffic on any port or port pair
— Fully compliant statistics (MIB) gathering counters
— Control registers configurable on-the-fly
Datasheet
Ports
Port 0 - MII MAC, MII PHY, RMII PHY modes
2 internal 10/100 PHYs with HP Auto-MDIX support
200Mbps Turbo MII (PHY or MAC mode)
Fully compliant with IEEE 802.3 standards
10BASE-T and 100BASE-TX support
Full and half duplex support
Full duplex flow control
Backpressure (forced collision) half duplex flow control
Automatic flow control based on programmable levels
Automatic 32-bit CRC generation and checking
2K Jumbo packet support
Programmable interframe gap, flow control pause value
Full transmit/receive statistics
Full LED support per port
Auto-negotiation
Automatic polarity correction
Automatic MDI/MDI-X
Loop-back mode
Target Applications
Cable, satellite, and IP set-top boxes
Digital televisions
Digital video recorders
VoIP/Video phone systems
Home gateways
Test/Measurement equipment
Industrial automation systems
Key Benefits
Ethernet Switch Fabric
— 32K buffer RAM
— 512 entry forwarding table
— Port based IEEE 802.1Q VLAN support (16 groups)
– Programmable IEEE 802.1Q tag insertion/removal
— IEEE 802.1D spanning tree protocol support
— 4 separate transmit queues available per port
— Fixed or weighted egress priority servicing
— QoS/CoS Packet prioritization
– Input priority determined by VLAN tag, DA lookup,
TOS, DIFFSERV or port default value
– Programmable Traffic Class map based on input
priority on per port basis
– Remapping of 802.1Q priority field on per port basis
– Programmable rate limiting at the ingress with
coloring and random early discard, per port / priority
– Programmable rate limiting at the egress with leaky
bucket algorithm, per port / priority
— IGMP v1/v2/v3 monitoring for Multicast packet filtering
— Programmable broadcast storm protection with global
% control and enable per port
— Programmable buffer usage limits
— Dynamic queues on internal memory
— Programmable filter by MAC address
SMSC LAN9303/LAN9303i
Serial Management
— I
2
C (slave) access to all internal registers
— MIIM (MDIO) access to PHY related registers
— SMI (extended MIIM) access to all internal registers
— General Purpose Timer
— I
2
C Serial EEPROM interface
— Programmable GPIOs/LEDs
Other Features
Single 3.3V power supply
ESD Protection Levels
— ±8kV HBM without External Protection Devices
— ±8kV contact mode (IEC61000-4-2)
— ±15kV air-gap discharge mode (IEC61000-4-2)
Latch-up exceeds ±150mA per EIA/JESD 78
56-pin QFN (8x8 mm) Lead-Free RoHS Compliant
Package
Available in Commercial & Industrial Temp. Ranges
DATASHEET
Revision 1.3 (08-27-09)
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
ORDER NUMBERS:
LAN9303-ABZJ FOR 56-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (0 TO 70°C TEMP RANGE)
LAN9303i-ABZJ FOR 56-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (-40 TO 85°C TEMP RANGE)
80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123
Copyright © 2009 SMSC or its subsidiaries. All rights reserved.
Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for
construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC
reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications
before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent
rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated
version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors
known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not
designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property
damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of
this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered
trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders.
SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE
OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT;
TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD
TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Revision 1.3 (08-27-09)
DATASHEET
2
SMSC LAN9303/LAN9303i
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
Table of Contents
Chapter 1 Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.1
General Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chapter 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 System Clocks/Reset/PME Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 System Interrupt Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.3 Switch Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.4 Ethernet PHYs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.5 PHY Management Interface (PMI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.6 I2C Slave Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.7 SMI Slave Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.8 EEPROM Controller/Loader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.9 GPIO/LED Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3
Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.1 Internal PHY Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.2 MAC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.3 PHY Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.4 Management Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
16
17
17
17
18
18
18
18
18
19
19
19
19
20
20
Chapter 3 Pin Description and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.1
Pin Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 56-QFN Pin Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2
Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3
Buffer Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
23
24
41
Chapter 4 Clocking, Resets, and Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.1
Clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.2
Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.2.1 Chip-Level Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.2.2
4.2.3
4.2.4
4.2.4.1
4.2.4.2
4.2.3.1
4.2.3.2
4.2.3.3
4.2.2.1
4.2.1.1
4.2.1.2
Multi-Module Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Single-Module Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Power-On Reset (POR) .................................................................................................................................................................................. 43
nRST Pin Reset .............................................................................................................................................................................................. 43
Digital Reset (DIGITAL_RST) ......................................................................................................................................................................... 44
Port 2 PHY Reset............................................................................................................................................................................................ 44
Port 1 PHY Reset............................................................................................................................................................................................ 45
Virtual PHY Reset ........................................................................................................................................................................................... 45
Soft-Straps ...................................................................................................................................................................................................... 46
Hard-Straps..................................................................................................................................................................................................... 52
Configuration Straps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.3
Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.3.1 Port 1 & 2 PHY Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Chapter 5 System Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
5.1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2
Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1 Switch Fabric Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2 Ethernet PHY Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.3 GPIO Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.4 General Purpose Timer Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.5 Software Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.6 Device Ready Interrupt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMSC LAN9303/LAN9303i
55
55
57
57
58
58
58
58
DATASHEET
3
Revision 1.3 (08-27-09)
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
Chapter 6 Switch Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
6.1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2
Switch Fabric CSRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.1 Switch Fabric CSR Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.2 Switch Fabric CSR Reads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.3 Flow Control Enable Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3
10/100 Ethernet MACs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1 Receive MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.2
6.3.2.1
6.3.1.1
59
59
60
61
62
64
64
Transmit MAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Receive Counters ........................................................................................................................................................................................... 65
Transmit Counters .......................................................................................................................................................................................... 66
6.4
Switch Engine (SWE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
6.4.1 MAC Address Lookup Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
6.4.1.1
6.4.1.2
6.4.1.3
6.4.1.4
6.4.1.5
6.4.1.6
6.4.1.7
6.4.2
6.4.3
6.4.3.1
6.4.3.2
6.4.3.3
6.4.3.4
Forwarding Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Transmit Priority Queue Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Learning/Aging/Migration ................................................................................................................................................................................ 68
Static Entries................................................................................................................................................................................................... 68
Multicast Pruning ............................................................................................................................................................................................ 68
Address Filtering ............................................................................................................................................................................................. 68
Spanning Tree Port State Override................................................................................................................................................................. 68
MAC Destination Address Lookup Priority...................................................................................................................................................... 68
Host Access .................................................................................................................................................................................................... 68
6.4.4
6.4.5
6.4.6
6.4.7
6.4.8
6.4.9
6.4.10
6.4.10.1
6.4.10.2
6.4.6.1
VLAN Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Spanning Tree Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Ingress Flow Metering and Coloring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Broadcast Storm Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IPv4 IGMP Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Host CPU Port Special Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Default Priority......................................................................................................................................................................................... 73
IP Precedence Based Priority ......................................................................................................................................................................... 73
DIFFSERV Based Priority............................................................................................................................................................................... 73
VLAN Priority .................................................................................................................................................................................................. 73
Ingress Flow Calculation................................................................................................................................................................................. 77
79
79
80
80
6.4.11 Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
6.5
Buffer Manager (BM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
6.5.1 Packet Buffer Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
6.5.2 Random Early Discard (RED). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.3 Transmit Queues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.4 Transmit Priority Queue Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.5 Egress Rate Limiting (Leaky Bucket) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.6 Adding, Removing, and Changing VLAN Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.7 Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.6
Switch Fabric Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.1.1
Packets from the Host CPU ............................................................................................................................................................................ 80
Packets to the Host CPU ................................................................................................................................................................................ 81
Buffer Limits and Flow Control Levels ............................................................................................................................................................ 82
82
83
83
83
84
87
87
Chapter 7 Ethernet PHYs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
7.1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1.1 PHY Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2
Port 1 & 2 PHYs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2.1 100BASE-TX Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2.1.1
7.2.1.2
7.2.1.3
7.2.1.4
7.2.1.5
7.2.1.6
7.2.2.1
7.2.2.2
88
88
89
90
7.2.2
100BASE-TX Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
MII MAC Interface ........................................................................................................................................................................................... 90
4B/5B Encoder................................................................................................................................................................................................ 90
Scrambler and PISO ....................................................................................................................................................................................... 92
NRZI and MLT-3 Encoding ............................................................................................................................................................................. 92
100M Transmit Driver ..................................................................................................................................................................................... 92
100M Phase Lock Loop (PLL) ........................................................................................................................................................................ 92
A/D Converter ................................................................................................................................................................................................. 93
DSP: Equalizer, BLW Correction and Clock/Data Recovery .......................................................................................................................... 93
Revision 1.3 (08-27-09)
DATASHEET
4
SMSC LAN9303/LAN9303i
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
7.2.2.3
7.2.2.4
7.2.2.5
7.2.2.6
7.2.2.7
7.2.3.1
7.2.3.2
NRZI and MLT-3 Decoding ............................................................................................................................................................................. 94
Descrambler and SIPO ................................................................................................................................................................................... 94
5B/4B Decoding .............................................................................................................................................................................................. 94
Receiver Errors ............................................................................................................................................................................................... 94
MII MAC Interface ........................................................................................................................................................................................... 94
MII MAC Interface ........................................................................................................................................................................................... 95
10M TX Driver and PLL .................................................................................................................................................................................. 95
7.2.3
7.2.4
7.2.4.1
7.2.4.2
7.2.4.3
7.2.4.4
10BASE-T Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
10BASE-T Receive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
7.2.5
7.2.5.1
7.2.5.2
7.2.5.3
7.2.5.4
7.2.5.5
PHY Auto-negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Filter and Squelch ........................................................................................................................................................................................... 95
10M RX and PLL............................................................................................................................................................................................. 95
MII MAC Interface ........................................................................................................................................................................................... 96
Jabber Detection............................................................................................................................................................................................. 96
PHY Pause Flow Control ................................................................................................................................................................................ 97
Parallel Detection............................................................................................................................................................................................ 98
Restarting Auto-Negotiation............................................................................................................................................................................ 98
Disabling Auto-Negotiation ............................................................................................................................................................................. 98
Half Vs. Full-Duplex ........................................................................................................................................................................................ 98
7.2.6
7.2.7
7.2.8
7.2.9
7.2.9.1
7.2.9.2
7.2.8.1
HP Auto-MDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
MII MAC Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
PHY Management Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
PHY Power-Down Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
PHY Interrupts .............................................................................................................................................................................................. 100
PHY General Power-Down ........................................................................................................................................................................... 101
PHY Energy Detect Power-Down ................................................................................................................................................................. 101
7.2.10 PHY Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
7.2.11 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2.12 Required Ethernet Magnetics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3
Virtual PHY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.1 Virtual PHY Auto-Negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.2
7.3.3
7.3.3.1
7.3.3.2
7.3.2.1
7.3.1.1
7.3.1.2
7.3.1.3
7.2.10.1
7.2.10.2
7.2.10.3
PHY Software Reset via RESET_CTL.......................................................................................................................................................... 101
PHY Software Reset via PHY_BASIC_CTRL_x ........................................................................................................................................... 101
PHY Power-Down Reset............................................................................................................................................................................... 101
102
102
102
102
Virtual PHY in MAC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Parallel Detection.......................................................................................................................................................................................... 103
Disabling Auto-Negotiation ........................................................................................................................................................................... 103
Virtual PHY Pause Flow Control ................................................................................................................................................................... 104
Full-Duplex Flow Control............................................................................................................................................................................... 104
Virtual PHY Software Reset via RESET_CTL .............................................................................................................................................. 104
Virtual PHY Software Reset via VPHY_BASIC_CTRL ................................................................................................................................. 105
Virtual PHY Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Chapter 8 Serial Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8.1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2
I2C Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3
I2C Master EEPROM Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.1 I2C EEPROM Device Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.2 I2C EEPROM Byte Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.3 I2C EEPROM Sequential Byte Reads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.4 I2C EEPROM Byte Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.5 Wait State Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.6 I
2
C Bus Arbitration and Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.3.6.1
8.3.6.2
8.3.6.3
8.3.6.4
106
106
107
108
108
109
109
110
110
8.3.7 I2C Master EEPROM Controller Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4
EEPROM Loader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4.1 EEPROM Loader Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4.2 EEPROM Valid Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4.3 MAC Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4.4 Soft-Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.4.5
8.4.4.1
8.4.4.2
8.4.4.3
Bus Busy....................................................................................................................................................................................................... 110
Clock Synchronization .................................................................................................................................................................................. 110
Arbitration...................................................................................................................................................................................................... 111
Timeout Due to Busy or Arbitration............................................................................................................................................................... 111
111
113
113
115
115
115
Register Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
PHY Registers Synchronization.................................................................................................................................................................... 115
Virtual PHY Registers Synchronization......................................................................................................................................................... 116
LED and Manual Flow Control Register Synchronization ............................................................................................................................. 116
SMSC LAN9303/LAN9303i
DATASHEET
5
Revision 1.3 (08-27-09)
查看更多>
参数对比
与LAN9303i相近的元器件有:LAN9303i-ABZJ、LAN9303。描述及对比如下:
型号 LAN9303i LAN9303i-ABZJ LAN9303
描述 IC ETHER SW 3PORT 16BIT 56QFN IC ETHER SW 3PORT 16BIT 56QFN IC ETHER SW 3PORT 16BIT 56QFN
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消