首页 > 器件类别 > 热门应用 > 无线/射频/通信

MASWSS0201TR

RF Switch ICs DC-2.5GHz 75 Ohm IL 1.1dB @1GHz

器件类别:热门应用    无线/射频/通信   

厂商名称:MACOM

厂商官网:http://www.macom.com

下载文档
MASWSS0201TR 在线购买

供应商:

器件:MASWSS0201TR

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
产品种类
Product Category
RF Switch ICs
制造商
Manufacturer
MACOM
RoHS
Details
Number of Switches
Dual
Switch Configuration
SPDT
Operating Frequency
2.5 GHz
Insertion Loss
1.5 dB
Off Isolation - Typ
43 dB
最大工作温度
Maximum Operating Temperature
+ 85 C
封装 / 箱体
Package / Case
PQFN-12
系列
Packaging
Reel
系列
Packaging
MouseReel
系列
Packaging
Cut Tape
最小工作温度
Minimum Operating Temperature
- 40 C
Off Time - Max
12 ns
On Resistance - Max
75 Ohms
On Time - Max
1.6 us
工作电源电流
Operating Supply Current
200 uA
工厂包装数量
Factory Pack Quantity
1000
技术
Technology
GaAs
文档预览
MASWSS0201
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
Features
Ideal for CATV, DTV, DVR, STB Applications
Default-On in Unpowered State (RFC-RF1 Path)
Broadband Performance: DC-2.5 GHz
Low Insertion Loss: 1.1 dB at 1 GHz
High Isolation: > 60dB @ 100MHz
Single Control Operation
Power Handling: > 20 dBm P1dB
Lead-Free 3 mm 12-lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free ―Green‖ Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Configurable for Non-terminated Operation
Rev. V1
Functional Schematic
GND
RFC
GND
N/C
RF1
Term 1
V
C
RF2
Term 2
GND
GND
Description
M/A-COM’s MASWSS0201 is a broadband GaAs
PHEMT MMIC SPDT terminated switch in a low
cost, lead-free 3 mm 12-lead PQFN package. The
MASWSS0201 is ideally suited for applications
where an unpowered on state is critical in a single
control line SPDT terminated switch.
The
unpowered condition is the same as the V
C
= 0
condition. This part can also be configured as a
reflective switch with minimal impact to the RF
performance.
The MASWSS0201 delivers high isolation, low
insertion loss and high linearity up to 2.5 GHz.
The MASWSS0201 is fabricated using a 0.5 micron
gate length GaAs E/D PHEMT process.
The
process features full passivation for performance
and reliability.
GND
N/C
GND
Pin Configuration
2
Pin No.
1
2
3
4
5
6
7
8
9
10
Pin Name
N/C
RF1
Term 1 GND
3
GND
N/C
GND
Term 2 GND
RF2
VC
GND
RFC
GND
Paddle
4
3
Description
No Connection
RF Port 1
Termination 1 Ground
Ground
No Connection
Ground
Termination 2 Ground
RF Port 2
Control
Ground
RF Input
Ground
RF and DC Ground
Ordering Information
1
Part Number
MASWSS0201TR-3000
MASWSS0201SMB
11
Package
3000 piece reel
Sample Test Board
(Includes 5 Samples)
12
13
1. Reference Application Note M513 for reel size information.
2. M/A-COM recommends that all unused (N/C) pins be
connected to ground. All data on this datasheet was taken
with N/C pins connected to ground.
3. Terminated grounds require DC blocking capacitors; see
application schematic.
4. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MASWSS0201
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
Electrical Specifications: T
A
= 25°C, Z
0
= 75
,
V
C
= 0 V/3 V, P
IN
= 0 dBm
5
Parameter
Insertion Loss RFC to RF1
(V
C
= 0V)
Insertion Loss RFC to RF2
(V
C
= 3V)
Rev. V1
Test Conditions
100 MHz
1.0 GHz
2.0 GHz
100 MHz
1.0 GHz
2.0 GHz
100 MHz
1.0 GHz
2.0 GHz (RFC - RF1)
2.0 GHz (RFC - RF2)
DC - 2.0 GHz
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
100 MHz
1.0 GHz
10% to 90% RF
90% to 10% RF
50% control to 90% RF
50% control to 10% RF
V
C
= 3V
Units
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dBm
dBm
µS
nS
µS
nS
mV
µA
Min.
60
40
Typ.
0.9
1.0
1.3
1.0
1.2
1.5
65
45
38
43
25
54 / 51 / 53
72 / 70 / 70
38 / 38 / 39
41 / 44 / 44
21 / 21 / 22
29 / 28 / 29
1.4
12
1.6
12
550
250
Max.
1.75
1.85
1.65
1.85
500
Isolation
Return Loss
IIP2
(V
C
= 0V / 3V / 5V)
IIP3
(V
C
= 0V / 3V / 5V)
Input P1dB
(V
C
= 0V / 3V / 5V)
T-rise
T-fall
Ton
Toff
Transients
Control Current
5. Electrical specifications apply to terminated configuration only.
Absolute Maximum Ratings
6,7
Parameter
Input Power @ 100 MHz
Input Power @ 1 GHz
Operating Voltage
Operating Temperature
Storage Temperature
Truth Table
8,9,10
Control V
C
0
1
Absolute Maximum
+22 dBm
+29 dBm
+8.5 volts
-40
°
C to +85
°
C
-65
°
C to +150°C
RFC-RF1
On
Off
RFC-RF2
Off
On
8. External DC blocking capacitors are required on all RF ports.
9. 0 = 0 ± 0.1 V, 1 = +2.9 V to +5 V.
10. The unpowered on state is the same as V
C
=0.
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM does not recommend sustained operation near
these survivability limits.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MASWSS0201
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
Insertion Loss
0.0
RFC to RF1 (Vc=0V)
Rev. V1
Typical Performance Curves:
T
A
= 25°C, Z
0
= 75

Components per Application Schematic
RFC Return Loss
0
RFC to RF1 (Vc=0V)
-0.5
RFC to RF2 (Vc=3V)
-10
RFC to RF2 (Vc=3V)
-1.0
-20
-1.5
-30
-2.0
-2.5
-40
-3.0
0.0
-50
0.5
1.0
1.5
2.0
2.5
3.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Frequency (GHz)
Isolation (Below 200 MHz)
-40
RFC to RF1 (Vc=3V)
RF1 Return Loss
0
RF1 to RFC (Vc=0V)
-50
RFC to RF2 (Vc=0V)
-10
RF1 Terminated (Vc=3V)
-60
-20
-70
-30
-80
-40
-90
25
50
75
100
125
150
175
200
225
250
-50
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (MHz)
Frequency (GHz)
Isolation (Above 200 MHz)
-20
RFC to RF1 (Vc=3V)
RF2 Return Loss
0
RF2 to RFC (Vc=3V)
-30
RFC to RF2 (Vc=0V)
-10
RF2 Terminated (Vc=0V)
-40
-20
-50
-30
-60
-40
-70
0.0
-50
0.5
1.0
1.5
2.0
2.5
3.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
3
Frequency (GHz)
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MASWSS0201
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
Lead-Free
3 mm 12-lead PQFN
Rev. V1
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Application Schematic
11,12
C1-C5=10000 pf
C6=100 pf
Qualification
Qualified to M/A-COM specification REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
M/A-COM’s AN3007 Application Note outlines a
method for ESD sensitivity mitigation. It can be
found at the Tech/Apps section of the
MACOM.COM website.
11. Non-connected pins (P1 and P5) are shown connected to
ground as recommended. All data on this datasheet was
taken with N/C pins connected to ground.
12. Application schematic shown is for terminated
configuration. For non-terminated operation Term 1 and
Term 2 ground pins are left open. See application section
for data in unterminated configuration.
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MASWSS0201
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
Application Section
Typical Performance Curves:
T
A
= 25°C, Z
0
= 75

Unterminated Configuration (Term 1&2 GND pins open)
Insertion Loss
0.0
RFC to RF1 (Vc=0V)
Rev. V1
RFC Return Loss
0
RFC to RF1 (Vc=0V)
-0.5
RFC to RF2 (Vc=3V)
-10
RFC to RF2 (Vc=3V)
-1.0
-20
-1.5
-30
-2.0
-2.5
-40
-3.0
0.0
-50
0.5
1.0
1.5
2.0
2.5
3.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Frequency (GHz)
Isolation (Below 200 MHz)
-40
RFC to RF1 (Vc=3V)
RF1 Return Loss
0
-50
RFC to RF2 (Vc=0V)
-10
RF1 to RFC (Vc=0V)
RF1 Unterminated (Vc=3V)
-60
-20
-70
-30
-80
-40
-90
25
50
75
100
125
150
175
200
225
250
-50
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (MHz)
Frequency (GHz)
Isolation (Above 200 MHz)
-20
RFC to RF1 (Vc=3V)
RF2 Return Loss
0
-30
RFC to RF2 (Vc=0V)
-10
RF2 to RFC (Vc=3V)
RF2 Unterminated (Vc=0V)
-40
-20
-50
-30
-60
-40
-70
0.0
-50
0.5
1.0
1.5
2.0
2.5
3.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Frequency (GHz)
5
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
查看更多>
热门器件
热门资源推荐
器件捷径:
00 01 02 03 04 05 06 07 08 09 0A 0C 0F 0J 0L 0M 0R 0S 0T 0Z 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 1H 1K 1M 1N 1P 1S 1T 1V 1X 1Z 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 2G 2K 2M 2N 2P 2Q 2R 2S 2T 2W 2Z 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 3G 3H 3J 3K 3L 3M 3N 3P 3R 3S 3T 3V 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4M 4N 4P 4S 4T 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5E 5G 5H 5K 5M 5N 5P 5S 5T 5V 60 61 62 63 64 65 66 67 68 69 6A 6C 6E 6F 6M 6N 6P 6R 6S 6T 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7M 7N 7P 7Q 7V 7W 7X 80 81 82 83 84 85 86 87 88 89 8A 8D 8E 8L 8N 8P 8S 8T 8W 8Y 8Z 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9F 9G 9H 9L 9S 9T 9W