Chassis mounting low voltage mains transformers with 230V ac primary winding.
2 secondary winding that can be connected in series or parallel.
Double section bobbins on interleaved lamination provide 3.75kV isolation.
Fixing by clamp on models up to 50VA, and frame construction above.
Tested to meet EN60065.
Specifications
Dimensions
VA
Width
6
12
20
50
75
100
150
200
45
59
Depth
40
50
56
62
75
68
78
90
Height
37
50
65
67
75
85
FC
54
72
92
54 x 54
57 x 44
72 x 58
72 x 68
Frame
Clamp
Fixing
Style
Weight
(kg)
0.2
0.4
0.55
1.0
1.5
1.6
2.2
2.8
7
Dimensions : Millimetres
Typical
Regulation
(%)
25
12
79
89
100
10
Page 1
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Part Numbers
Rating
0-5V, 0-5V @ 0.6A
0-6V, 0-6V @ 0.5A
0-9V, 0-9V @ 0.33A
0-12V, 0-12V @ 0.25A
0-15V, 0-15V @ 0.2A
0-18V, 0-18V @ 0.17A
0-20V, 0-20V @ 0.15A
0-24V, 0-24V @ 0.12A
0-5V, 0-5V @ 1.2A
0-6V, 0-6V @ 1A
0-9V, 0-9V @ 0.67A
0-12V, 0-12V @ 0.5A
0-15V, 0-15V @ 0.4A
0-18V, 0-18V @ 0.33A
0-20V, 0-20V @ 0.3A
0-24V, 0-24V @ 0.25A
0-5V, 0-5V @ 2A
0-6V, 0-6V @ 1.67A
0-6.3V, 0-6.3V @ 1.59A
0-9V, 0-9V @ 1.1A
0-12V, 0-12V @ 0.83A
0-18V, 0-18V @ 0.55A
0-20V, 0-20V @ 0.5A
0-24V, 0-24V @ 0.42A
0-6V, 0-6V @ 4.17A
0-9V, 0-9V @ 2.78A
0-12V, 0-12V @ 2.08A
0-15V, 0-15V @ 1.67A
0-18V, 0-18V @ 1.39A
0-20V, 0-20V @ 1.25A
0-24V, 0-24V @ 1.04A
50VA - 10% Typical
Regulation
20VA - 10% Typical
Regulation
12VA - 12% Typical
Regulation
6VA - 25% Typical
Regulation
Load
Part Number
MCF/B1805F
MCF/B1806F
MCF/B1809F
MCF/B1812F
MCF/B1815F
MCF/B1818F
MCF/B1820F
MCF/B1824F
MCF/N3505F
MCF/N3506F
MCF/N3509F
MCF/N3512F
MCF/N3515F
MCF/N3518F
MCF/N3520F
MCF/N3524F
MCF/R3505F
MCF/R3506F
N/A
MCF/R3509F
MCF/R3512F
MCF/R3518F
MCF/R3520F
MCF/R3524F
MCF/D2906F
MCF/D2909F
MCF/D2912F
MCF/D2915F
MCF/D2918F
MCF/D2920F
MCF/D2924F
Page 2
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Part Numbers
Rating
0-6V, 0-6V @ 6.25A
0-9V, 0-9V @ 4.17A
0-12V, 0-12V @ 3.12A
0-15V, 0-15V @ 2.5A
0-18V, 0-18V @ 2.08A
0-24V, 0-24V @ 1.56A
0-50V, 0-50V @ 0.75A
0-6V, 0-6V @ 8.33A
0-9V, 0-9V @ 5.55A
0-12V, 0-12V @ 4.17A
0-15V, 0-15V @ 3.33A
0-18V, 0-18V @ 2.78A
0-20V, 0-20V @ 2.5A
0-24V, 0-24V @ 2.08A
0-30V, 0-30V @ 1.67A
0-50V, 0-50V @ 1A
0-6V, 0-6V @ 12.5A
0-9V, 0-9V @ 8.33A
0-12V, 0-12V @ 6.25A
0-15V, 0-15V @ 5A
0-18V, 0-18V @ 4.17A
0-24V, 0-24V @ 3.12A
0-50V, 0-50V @ 1.5A
0-6V, 0-6V @ 16.7A
0-9V, 0-9V @ 11.1A
0-12V, 0-12V @ 8.3A
0-15V, 0-15V @ 6.67A
0-18V, 0-18V @ 5.55A
0-20V, 0-20V @ 5A
0-24V, 0-24V @ 4.17A
0-30V, 0-30V @ 3.33A
0-50V, 0-50V @ 2A
200VA - 7% Typical
Regulation
150VA - 10% Typical
Regulation
100VA - 10% Typical
Regulation
75VA - 10% Typical
Regulation
Load
Part Number
MCF/T2906F
MCF/T2909F
MCF/T2912F
MCF/T2915F
MCF/T2918F
MCF/T2924F
MCF/T2950F
MCF/B19606F
MCF/B19609F
MCF/B19612F
MCF/B19615F
MCF/B19618F
MCF/B19620F
MCF/B19624F
N/A
MCF/B19650F
MCF/T9606F
MCF/T9609F
MCF/T9612F
MCF/T9615F
MCF/T9618F
MCF.T9624F
MCF/T9650F
MCF/Y9606F
MCF/Y9609F
MCF/Y9812F
MCF/Y9615F
MCF/Y9618F
MCF/Y9620F
MCF/Y9624F
N/A
MCF/Y9650F
Page 3
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Notes:
International Sales Offices:
AUSTRALIA
– Farnell InOne
Tel No:
++ 61 2 9645 8888
Fax No: ++ 61 2 9644 7898
FINLAND
– Farnell InOne
Tel No:
++ 358 9 560 7780
Fax No: ++ 358 9 345 5411
NETHERLANDS
– Farnell InOne
Tel No:
++ 31 30 241 7373
Fax No: ++ 31 30 241 7333
SWITZERLAND
– Farnell InOne
Tel No: ++ 41 1 204 64 64
Fax No: ++ 41 1 204 64 54
AUSTRIA
– Farnell InOne
Tel No:
++ 43 662 2180 680
Fax No: ++ 43 662 2180 670
FRANCE
– Farnell InOne
Tel No:
++ 33 474 68 99 99
Fax No: ++ 33 474 68 99 90
NEW ZEALAND
– Farnell InOne
Tel No:
++ 64 9 357 0646
Fax No: ++ 64 9 357 0656
UK
– Farnell InOne
Tel No:
++ 44 8701 200 200
Fax No: ++ 44 8701 200 201
BELGIUM
– Farnell InOne
Tel No:
++ 32 3 475 2810
Fax No: ++ 32 3 227 3648
GERMANY
– Farnell InOne
Tel No:
++ 49 89 61 39 39 39
Fax No: ++ 49 89 613 59 01
NORWAY
– Farnell InOne
Tel No:
++ 45 44 53 66 66
Fax No: ++ 45 44 53 66 02
UK
–
BuckHickman InOne
++ 44 8450 510 150
++ 44 8450 510 130
BRAZIL
– Farnell-Newark InOne
Tel No:
++ 55 11 4066 9400
Fax No: ++ 55 11 4066 9410
HONG KONG
–
Farnell-Newark InOne
Tel No: ++ 852 2268 9888
Fax No: ++ 852 2268 9899
PORTUGAL
– Farnell InOne
Tel No:
++ 34 93 475 8804
Fax No: ++ 34 93 474 5288
UK
–
CPC
++ 44 8701 202 530
++ 44 8701 202 531
CHINA
– Farnell-Newark InOne
Tel No:
++86 10 6238 5152
Fax No: ++86 10 6238 5022
IRELAND
– Farnell InOne
Tel No:
++ 353 1 830 9277
Fax No: ++ 353 1 830 9016
SINGAPORE
–
Farnell-Newark InOne
Tel No: ++ 65 6788 0200
export
EXPORT
– Farnell InOne
Tel No:
++ 44 8701 200 208
Fax No: ++ 44 8701 200 209
Fax No: ++ 65 6788 0300
For enquiries from all other markets
DENMARK
– Farnell InOne
Tel No:
++ 45 44 53 66 44
Fax No: ++ 45 44 53 66 06
ITALY
– Farnell InOne
Tel No:
++ 39 02 93 995 200
Fax No: ++ 39 02 93 995 300
SPAIN
– Farnell InOne
Tel No:
++ 34 93 475 8805
Fax No: ++ 34 93 474 5107
http://www.farnellinone.com
ESTONIA
– Farnell InOne
Tel No:
++ 358 9 560 7780
Fax No: ++ 358 9 345 5411
MALAYSIA
–
Farnell-Newark InOne
Tel No: ++ 60 3 7873 8000
Fax No: ++ 60 3 7873 7000
SWEDEN
– Farnell InOne
Tel No:
++ 46 8 730 50 00
Fax No: ++ 46 8 83 52 62
http://www.buckhickmaninone.com
http://www.cpc.co.uk
Disclaimer
This data sheet and its contents (the "Information") belong to the Premier Farnell Group (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes
in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied.
The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data
sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage
resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded.