Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Conditions
Autoranging
Min.
90
180
47
Typ.
Max.
132
264
63
Units
VAC
Hz
A
35
70
1.0
A
mA
110 VAC
6
220 VAC
3
110 VAC
220 VAC
264 VAC
Meets EN 61000-3-2 Class A
T8A/250V Fuse
Conditions
By Trim Pot
Min.
Typ.
±5.0
±1.0
Output
Parameter
Output Voltage Adjustment
Output Regulation, See Note 1
Hold Time
Ripple & Noise (20 MHz) See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Max.
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
110 VAC, 80% Load
20
See Model Selection Guide
Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+110
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
230 VAC
1
Continuous With Autorecovery
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Units
VAC
25
kHz
Interface Signals
Power Supply On
Power Good Signal
Green LED on the PCB
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation.
A TTL low signal inhibits the output. Hiccup mode.
Conditions
Min.
Typ.
Max.
Units
Ambient
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Remote On/Off
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 61000-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s
2
on X, Y & Z Axis
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPU-250S-12
YZ
MPU-250S-15
YZ
MPU-250S-24
YZ
MPU-250S-36
YZ
www.micropowerdirect.com
11.25
9.00
5.62
3.75
20.83
16.66
10.41
5.21
±1%
±1%
±1%
±1%
83%
83%
83%
83%
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 kHz to 20 MHz. Connection to the unit is made with
a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel.
3. A 1% minimum load is required to maintain regulation & ripple specifications.
4. Transient recovery is measured to within a 1% error band for a load step of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
6. The full output range (see table) is covered in the safety agency certification. Standard
models are factory set to the Preset voltage, but may be set to other levels within the range
without affecting the agency certification. For more information, contact the factory.
7. Output power is given for the factory preset voltage. The maximum continuous output
power level is 135W without providing 16 CFM airflow. All models provide a peak power
level of 600W for a maximum duration of 500
µS.
For more information, contact the factory.
8. Each unit includes an input fuse (250V/8A). Since this fuse is not field replaceable, it is
recommended that an external fuse of the same size be used on the input of the power
supply for protection.
Output Voltage
(VDC)
Output Current
(Max A)
Ripple
& Noise Efficiency
With
(%)
PreSet
Range
Convection 16 CFM
(% p-p)
12 VDC 11.0 - 13.8
15 VDC 14.0 - 15.5
24 VDC 21.0 - 26.0
36 VDC 35.0 - 42.0
Model Number
Mechanical Dimensions
Models with other output voltage levels
are available (i.e. 5 VDC, 48 VDC, etc)
Contact the factory for details at:
sales@micropowerdirect.com
Connections
I
nput Connector (CN1):
•
Terminal Block:
Howder HD-601-3P
3 pins, 6.35 mm Centers
•
Molex Mating Part No:
Molex 09-91-0500 or equivalent
(two pins removed)
Pin
1
2
3
Function
AC-Line
AC-Neutral
Field Ground
Output Connector (CN2):
•
Terminal Block:
Howder HD-601-4P
4 pins, 6.35 mm Centers
•
Molex Mating Part No:
Molex 09-91-0600 or equivalent
Pin
1
2
3
4
5
6
Molex
+V
OUT
+V
OUT
+V
OUT
-V
OUT
-V
OUT
-V
OUT
Pin Howder
1
2
3
4
+V
OUT
+V
OUT
-V
OUT
-V
OUT
U-Chassis Cover
(C Suffix)
Logic Signal Connector (CN3):
•
Mating Part No:
JST XHP-3 or equivalent
(CHYAO SHIUNN JS-2001-03)
•
Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
Pin
1
2
3
Function
Power Good
Remote On/Off
Common
Fan Driver Connector (CN4):
•
Mating Part No:
JST XHP-2 or equivalent
(CHYAO SHIUNN JS-2001-2)
Pin
1
2
Function
Minus
Plus
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.50)
FAX: (781) 344-8481
•
TEL: (781) 344-8226
•
E-Mail: sales@micropowerdirect.com