General-purpose Relay
MY
An Improved Miniature Power Relay with
Many Models for Sequence Control and
Power Applications
A wide range of relay variations including ones with operation
indicators, built-in diodes, etc.
Arc barrier standard on 3- and 4-pole Relays.
Dielectric strength: 2,000 VAC.
LR
Ordering Information
List of Models
Type
Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
With indicator
Standard
DPDT
DPDT (bifurcated)
3PDT
4PDT
4PDT (bifurcated)
With built-in diode
(DC only)
DPDT
DPDT (bifurcated)
3PDT
4PDT
4PDT (bifurcated)
With built-in CR
(AC only)
DPDT
DPDT (bifurcated)
3PDT
4PDT
4PDT (bifurcated)
With test button
DPDT
4PDT
Note:
MY2
MY2Z
MY3
MY4
MY4Z
MY2-D
MY2Z-D
MY3-D
MY4-D
MY4Z-D
MY2-CR
MY2Z-CR
MY3-CR
MY4-CR
MY4Z-CR
MY2I4
MY4I4
MY2N
MY2ZN
MY3N
MY4N
MY4ZN
MY2N-D2
MY2ZN-D2
MY3N-D2
MY4N-D2
MY4ZN-D2
MY2N-CR
–––
–––
MY4N-CR
–––
MY2I4N
MY4I4N
MY2-02
MY2Z-02
MY3-02
MY4-02
MY4Z-02
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
–––
MY2F
MY2ZF
MY3F
MY4F
MY4ZF
–––
–––
–––
–––
–––
Not available.
1.
When ordering, add the rated coil voltage to the model number.
Rated coil voltages are given in the coil ratings table.
Example: MY2, 6 VAC
Rated coil voltage
2.
The standard contacts for MY2Z-series Relays and for the MY4Z are gold-plated.
1
MY
MY
Accessories (Order Separately)
Sockets
Poles
Front-mounting socket
(DIN-rail/screw mounting)
2
PYF08A
PYF08A-E (finger protection)
PYF08A-N (finger protection)
PYF11A
PYF14A
PYF14A-N (finger protection)
PYF14A-E (finger protection)
PY08
Solder terminals
W/ clip
W/o clip
PY08-Y1
Back-mounting socket
Wire-wrap terminals
W/ clip
PY08QN
W/o clip
PY08QN-Y1
PCB
terminals
PY08–02
3
4
PY11
PY14
PY14-3*
PY11-Y1
PY14-Y1
PY11QN
PY14QN
PY11QN-Y1
PY14QN-Y1
PY11-02
PY14-02
Note:
*1. Equipped with operation check terminal.
2. The PYF08A(-E), PYF11A, and PYF14A(-E) have been approved as individual sockets by UL S08 and CSA C22.2.
Mounting Plates for Sockets
Socket model
PY08, PY11, PY14, PY08QN(2),
PY11QN(2), PY14QN(2)
Note:
PYP-1
For 1 socket
PYP-18
For 18 sockets
PYP-36
For 36 sockets
PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of sockets.
Socket Hold-down Clip Pairing
Relay type
Poles
Front-connecting
sockets
(rail-/screw-mounted)
Socket
Standard, bifurcated contacts, operation
indicator, built-in diode.
2
PYF08A-N,
PYF08A-E,
PYF08A
PYF11A
PYF14A-N,
PYF14A-E,
PYF14A
PYF08A-N,
PYF08A-E,
PYF08A
PYF11A
PYF14A-N,
PYF14A-E,
PYF14A
PYF08A-N,
PYF08A-E,
PYF08A
PYF11A
PYF14A-N,
PYF14A-E,
PYF14A
Y92H-3
PYC-A1
Clip
PYC-A1
Socket
PY08(QN)
Back-connecting sockets
Solder/wire-wrap terminals
PCB terminals
Socket
PY08(QN)
Clip
PYC-P
Clip
PYC-P
3
4
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
Test button
2
PY08(QN)
PYC-P2
PY08(QN)
PYC-P2
3
4
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
CR circuit
2
PY08(QN)
PYC-1
PY08(QN)
PYC-1
3
4
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
2
MY
MY
Specifications
Coil Ratings
Rated voltage
Rated current
50 Hz
AC
6V
12 V
24 V
50 V
100/110 V
110/120 V
200/220 V
220/240 V
DC
6V
12 V
24 V
48 V
100/110 V
214.1 mA
106.5 mA
53.8 mA
25.7 mA
11.7/12.9 mA
9.9/10.8 mA
6.2/6.8 mA
4.8/5.3 mA
150 mA
75 mA
36.9 mA
18.5 mA
9.1/10 mA
60 Hz
183 mA
91 mA
46 mA
22 mA
10/11 mA
8.4/9.2 mA
5.3/5.8 mA
4.2/4.6 mA
12.2
:
46
:
180
:
788
:
3,750
:
4,430
:
12,950
:
18,790
:
40
:
160
:
650
:
2,600
:
11,000
:
Coil
resistance
es sta ce
Inductance
(reference value)
Arm.
OFF
0.04 H
0.17 H
0.69 H
3.22 H
14.54 H
19.20 H
54.75 H
83.50 H
0.17 H
0.73 H
3.20 H
10.60 H
45.60 H
Arm. ON
0.08 H
0.33 H
1.30 H
5.66 H
24.6 H
32.1 H
94.07 H
136.40 H
0.33 H
1.37 H
5.72 H
21.00 H
86.20 H
10%
min.
0.9 W
0.9 to
1.1
1 1 VA
(60 Hz)
80%
max.
Must
operate
Must
release
Max.
voltage
% of rated voltage
30%
min.
110%
Power
consum.
co su
(A
)
(Approx.)
1.0 to
1 2 VA
1.2
(60 Hz)
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23qC with tolerances of +15%/–20% for rated currents
and
r15%
for DC coil resistance.
2. Performance characteristic data are measured at a coil temperatures of 23qC.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
resistor if required.
Contact Ratings
Item
Double- or three-pole
Resistive load
(cosf = 1)
Rated load
Carry
current
Max.
switching
voltage
Max.
switching
current
Max.
switching
capacity
Min.
permissible
load*
5 A, 220 VAC
5 A, 24 VDC
5A
250 VAC
125 VDC
5A
5A
Inductive load
(cosf=0.4,
L/R=7 ms)
2 A, 220 VAC
2 A, 24 VDC
Resistive load
(cosf = 1)
3 A, 220 VAC
3 A, 24 VDC
3A
250 VAC
125 VDC
3A
3A
Four-pole
Inductive load
(cosf=0.4,
L/R=7 ms)
0.8 A, 220 V
1.5 A, 24 VDC
1,100 VA
120 W
440 VA
48 W
660 VA
72 W
176 VA
36 W
Standard type: 100 mA, 5 VDC
Bifurcated type: 100
PA,
1 VDC
Standard type: 1
mA, 1 VDC
Bifurcated type: 100
PA,
1 VDC
*Note:
P level:
O
60
= 0.1 x 10
-6
/operation, reference value
3
MY
MY
Characteristics
Item
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Ambient operating temperature*
50 m: max.
20 ms max.
20 ms max.
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M: min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
Destruction: 10 to 55 Hz, 1.0-mm double amplitude
Malfunction: 10 to 55 Hz, 1.0-mm double amplitude
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 200 m/s
2
(approx. 20G)
See following table.
Single- and double-pole standard, bifurcated-contact, test-button, relays:
–55qC to 70qC (with no icing)
All other relays: –55qC to 60qC (with no icing)
35% to 85%
Approx. 85 g
All relays
Ambient operating humidity
Weight
Note:
The values given above are initial values.
Life Expectancy Characteristics
Relays
Normal, With test button (except relays with operation
indicator), With CR
With operation indicator or built-in diode
With bifurcated contacts
Note:
Mechanical life
(at 18,000 operations/hr)
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
2-pole: 50,000,000 operations min.
4-pole:
Electrical life
(at 1,800 operations/hr under rated load)
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
2-pole: 200,000 operations min.
4-pole: 100,000 operations min.
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated voltage
100 VAC
Load type
AC motor
Conditions
50 W, 100 VAC single-phase with
2.8-A inrush current, 0.4-A carry
current
50 W, 100 VAC single-phase with
1.6-A inrush current, 1-A carry current
AC solenoid
24 W with 1-A carry current
Operating frequency
ON for 2 s, OFF for 30 s
Electrical life
100,000 operations
ON for 1 s, OFF for 30 s
ON for 1.5 s, OFF for 1.5 s
300,000 operations
4,000,000 operations
MY4
Rated voltage
100 VAC
Load type
AC solenoid
DC magnetic
switch
AC magnetic
switch
24 VDC
DC solenoid
Conditions
50 VA with 2-A inrush current, 0.7A
carry current
25 W with L/R = 40 ms , 0.2-A carry
current
35 VA with 1.5-A inrush current,
0.35-A carry current
40 W with L/R = 10 ms, 1.6-A carry
current
30 W with L/R = 10 ms with 0.34-A
carry current
ON for 0.5 s, OFF for 1.5 s
ON for 0.5 s, OFF for 1.5 s
500,000 operations
5,000,000 operations
6,000,000 operations
Operating frequency
ON for 1 s, OFF for 3 s
Electrical life
25,000 operations
4
MY
MY
Approved by Standards
Some MY Relays are available in models meeting various safety
standards. When ordering, you must specify the desired standards.
Refer to
Ordering Information
for specific models. Note that the rat-
ing recognized by the various standards sometimes vary from the
ratings of the individual relays.
UL 508 Recognitions (File No. 41515)
No. of poles
2
Coil ratings
6 to 240 VAC
6 to 125 VDC
Contact ratings
5 A, 120 VAC resistive load
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
6 to 240 VAC
6 to 125 VDC
3 A 28 VDC resistive load
3 A 120 VAC inductive load
1.5 A, 240 VAC inductive load
5 A, 240 VAC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
LR (No. 563KOB-204524)
Model
MY -LR
2
No. of
poles
Coil
ratings
6 to 240
VAC
6 to 120
VDC
Contact ratings
2 A, 30 VDC inductive
load
2 A, 200 VAC inductive
load
1.5 A, 30 VDC
inductive load
0.8 A, 200 VAC
inductive load
1.5 A, 115 VAC
inductive load
3
4
4
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model
MY
No. of
poles
2, 3
Coil
ratings
6 to 240
VAC
6 to 120
VDC
Contact ratings
5 A, 28 VDC resistive
load
5 A, 240 VAC inductive
load
3 A, 28VDC resistive
load
3 A, 240 VAC inductive
load
5 A, 240 VAC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
4
Engineering Data
Maximum Switching Capacity
MY2, MY3
AC resistive load
AC inductive load
(cosf = 0.4)
Switching current (A)
DC resistive
load
DC inductive
load (L/R = 7 ms)
Switching voltage (V)