Features
*R
oH
S
**
CO
HA
LO & MP
LI
GE
AN
N
T
FR
EE
Applications
Battery cell protection for:
Notebook PCs
Tablet PCs
Smart phones
Mobile phones
Smallest body size, low current type
Overtemperature and overcurrent protection
67
1 2
1 5
C
7
7C
B0
NR
for lithium polymer and prismatic cells
Controls abnormal, excessive current
instantaneously
Wide range of temperature options
Komatsulite
NR Series C-Type Breaker
Ratings
Specification
Trip Temperature
Reset Temperature
Contact Rating
Maximum Breaking Current
Maximum Voltage
Minimum Holding Voltage
Maximum Leakage Current
Resistance
Product Dimensions
4.8 ± 0.1
(.189 ± .004)
Model
NR72CB0
72 °C ± 5 °C
NR77CB0
77 °C ± 5 °C
NR82CB0
82 °C ± 5 °C
NR85CB0
85 °C ± 5 °C
40 °C min.
DC12V / 12 A, 6000 cycles
DC5V / 30 A, 100 cycles
DC28V / 12 A, 100 cycles
2 V @ 25 °C for 1 minute
150 mA max. @ 25 °C
15 milliohms max.
Agency Recognition
Description
3.2 ± 0.1
(.126 ± .004)
0.1 ± 0.01
(.004 ± .0004)
3.2 ± 0.1
(.126 ± .004)
UL, cUL
TUV
File Number: E215638
File Number: R50281578
2.0 ± 0.1
(.079 ± .004)
2.0 ± 0.1
(.079 ± .004)
2.8 ± 0.1
(.110 ± .004)
0.89 ± 0.05
(.035 ± .002)
How to Order
NR 77 C B 0
DIMENSIONS:
MM
(INCHES)
Series Designator
Trip Temperature (±5 °C)
• 72
• 82
• 77
• 85
Arm Material
C = Cu Alloy Low Current Type
Product Structure
COVER
ARM
TERMINAL
ARM
COVER
PLATE
CONTACT
Terminal Type
(with/without Projection & Terminal Length)
Manufacturer’s Internal Code
PROJECTION
BASE
PTC
BIMETAL DISC
BASE
TERMINAL
PROJECTION
AVAILABLE WITH AND WITHOUT PROJECTIONS.
* RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
**Bourns considers a product to be “halogen free” if (a) the Bromine (Br) content is 900 ppm or less; (b) the Chlorine (Cl) content is 900 ppm or less; and (c) the total Bromine (Br)
and Chlorine (Cl) content is 1500 ppm or less.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ NR Series C-Type Breaker
MF-NSMF Series - PTC Resettable Fuses
Typical Performance
Current vs. Temperature Curves
10
9
8
7
6
NR72CB0 (Low 67 °C average)
NR77CB0 (Low 72 °C average)
NR82CB0 (Low 77 °C average)
NR85CB0 (Low 80 °C average)
Current (A)
5
4
3
2
1
0
20
30
40
50
60
70
80
Ambient Temperature (°C)
The above curves were derived from placing test samples in an oven at 25 ℃, 40 ℃, 60 ℃ and 70℃, increasing current flow through the
sample at a rate of 0.1 A/minute and recording the current value when the sample trips.
Operation
NORMAL CIRCUIT
CURRENT
EXCESSIVE
CURRENT
AND/OR
HEAT
CIRCUIT
AFTER OPENING
VERY LOW CURRENT
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ NR Series C-Type Breaker
MF-NSMF Series - PTC Resettable Fuses
Wiring Recommendations
This is not a surface mount device for reflow soldering. Therefore, Ni tab wiring should be accomplished by either resistance or laser welding.
Solder connections should be avoided.
Typical Part Marking
DATE CODE:
MONTH (1~9, X, Y, Z)
DATE
YEAR
MACHINE NO.
ROMAN NUMERAL (I,
II, III,
ETC
.) = OKAYAMA FACTORY
ARABIC NUMERAL (
1, 2, 3, ETC.
) = SHIGA FACTORY
MANUFACTURER’S TRADEMARK
1253A
DIRECTION MARK
(ALPHANUMERIC
CHARACTER)
**
NR77CB0
MANUFACTURER’S INTERNAL CODE
TERMINAL TYPE
ARM MATERIAL
(C = Cu ALLOY)
TRIP TEMPERATURE - °C
(72, 77, 82, 85)
SERIES DESIGNATOR
Standard Packaging Specifications
Plastic Bag.......................................................................................................................................................................1,000 pcs. (fixed)
Inner Box .........................................................................................................................................................................5,000 pcs. (fixed)
Outer Box ....................................................................................................................................50,000 pcs. max. (up to 10 inner boxes)
Japan:
Tel: +81-6 6319 2281 • Fax: +81-6 6319 2284
Asia-Pacific:
Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA:
Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas:
Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com/komatsulite
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ NR Series C-Type Breaker
MF-NSMF Series - PTC Resettable Fuses
Caution when using Breaker
Before using the breaker, please fully read the
DESIGN AND HANDLING CAUTIONS
stated below so that there will be no breaker
performance deterioration and/or damage to the breaker body or terminal.
DESIGN CAUTIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
Use within the electrical ratings specified in this data sheet. If used over the rating of voltage or current, ON-OFF life might be impacted
and contact may be deteriorated due to breaker arm damage.
If used over the electrical rating, the circuit may not open safely. Please test your device for any abnormalities and confirm that the breaker
will open the circuit safely in your device.
Mount the breaker on your device where heat is the highest in order to transfer it effectively to the breaker.
After the breaker is mounted, affix it so that the breaker body and terminals will not move. If not affixed, breaker resistance could increase
or contact open due to stress during handling or vibration/shock during transportation.
Mount the breaker body and terminals in a straight and flat direction. If the body and terminals are mounted in a twisted condition, breaker
resistance could increase or create body damage.
If breaker is to be resin-molded, test and evaluate to determine whether the breaker can be used effectively.
The breaker cannot be used as a repetitive ON-OFF thermostat.
The breaker is not washable. Do not wash.
The breaker is not designed nor guaranteed for flow, reflow or hand-soldering applications. If such application is required, test and
evaluate in your specific application to confirm that the breaker can be used.
10. When mounting and after mounting the breaker, do not apply supersonic vibration. Vibration and heat may cause the breaker resistance
to increase or may cause body damage. If you apply supersonic vibration after mounting the breaker, test and evaluate in your specific
application to confirm that the breaker can be used.
11. Do not use the breaker in the following abnormal environments:
a) Water, oil, chemicals or organic solutions
b) Direct sunlight, outdoor exposure, dust
c) Dew condensation, allowing the breaker to get wet
d) Salt breeze, chlorine, hydrogen sulfide, ammonium, sulfide-oxidation, hydrogen chloride, and anywhere there is a possibility of
generating corrosive gas such as ulfurous acid gas
e) Strong static electric charge or electromagnetic wave
12. Thie breaker is not designed or tested for, and should not be used in aerospace, airplane, nuclear, military, life-sustaining medical and
other related equipment.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ NR Series C-Type Breaker
MF-NSMF Series - PTC Resettable Fuses
Caution when using Breaker (Continued)
HANDLING CAUTIONS
1.
2.
3.
Since the breaker body is composed of plastic parts, do not clamp or dent with tools as this could cause a resistance increase or body
damage.
Breaker terminals are thin copper-alloy with right angle edges. Handle carefully to avoid injury to fingers. Handling while wearing finger
cots and tweezers is recommended.
When welding breaker terminals or mounting the breaker on a cell or PCM board, be careful to avoid placing excessive stress on the
breaker body and terminals. Excessive stress may cause a resistance increase or body damage. Please refer to the following cautions:
a) Do not apply more than 10 N moment to the breaker body (refer to Figure 1)
b) Do not apply more than 1.5 cN-m twist torque to the breaker body (refer to Figure 2)
c) Do not apply more than 20 N bending force to the breaker body (refer to Figure 3)
d) Do not apply more than 0.6 cN-m twist torque to the breaker terminals (refer to Figure 4)
e) Do not apply more than 2 N force to the breaker terminals (refer to Figure 5)
f)
Do not bend terminals more than 45 ° at root (refer to Figure 6)
g) Do not twist terminals more than 20 ° with the breaker body affixed.
4.
5.
In breaker body welding, normally there is direct welding (Figure 7) and series welding (Figure 8). In either case, use a suitable jig so that
there will be no stress as stated above.
Pull-and-detach strength of the terminal welding should be to your own specification. If the welding result is controlled by resistance,
measurement should be made at close point to the breaker body by “4-point clip method” using a milliohm meter to ensure accuracy
(refer to Figure 9).
Avoid putting stress as shown above in 3-a) to 3-g) when the jig is used for welding/additional processing.
6.
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
45 °
45 °
Figure 6
45 °
45 °
Figure 7
Rod A
Figure 8
Rod A
Rod B
Rod B
Figure 9
Due to possible updates to safety standards and other reasons, there may be changes in
specifications for this data sheet without prior notification. Therefore, before design-in for
your application, please contact us for the most up-to-date specifications.
milliohm meter
REV. 08/15
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
查看更多>
参数对比
与NR77CB0相近的元器件有:NR72CB0、NR82CB0、NR85CB0。描述及对比如下:
型号 NR77CB0 NR72CB0 NR82CB0 NR85CB0
描述 Komatsulite™ NR Series C-Type Breaker Komatsulite™ NR Series C-Type Breaker Komatsulite™ NR Series C-Type Breaker Komatsulite™ NR Series C-Type Breaker
msp430f149最小系统电路图
msp430f149最小系统电路图 msp430f149最小系统电路图 资料都在这里...
Aguilera 微控制器 MCU
关于数据采集和处理
不知道大家平常使用的方法大概有多少: 我们平时搞产品的时候很多情况会 通过读AD值来处理输入数据的...
and01 Microchip MCU
学完了STM32的ARM,好找工作吗
请问各位大哥们,我正在学STM32的ARM,学了这个好找工作吗 学...
menglin stm32/stm8
多芯电缆测试仪的研制
1 引言   种类繁多的通讯电缆、控制电缆在各种仪器和控制设备中大量使用。电缆线是否良好导通、线间...
测试/测量
430F149的信息段FLASH中定义变量问题
把几个需要掉电保存的变量定义在信息段flash中。 参见斑竹以及几位大侠的介绍,我修改了xcl(连接...
pala3cecili 微控制器 MCU
消费电子产品:不是我们的笨脑袋能想明白的?
笔者的结论是:如果某产品的用户界面太拙劣,以至于普通消费者无法理解的话,那么该产品就是有缺陷的,即便...
songbo 移动便携
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消