PHE830
• EMI suppressor, class X2, metallized polyester
• 0.01 – 2.2 µF, 275 VAC, +100°C
TYPICAL APPLICATIONS
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
CONSTRUCTION
Series winding of metallized polyester,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0
TECHNICAL DATA
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category
Approvals
275 VAC 50/60 Hz
0.01 – 2.2 µF
± 20% standard, ± 10% option
–40 to +100°C
40/100/56/C
S, VDE, UL, CSA
Tolerance in lead length
< 30 mm
+0
mm
–1
p
15.0 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
d
0.8
0.8
0.8
1.0
std l
17
6
6
6
max l
30
30
30
30
b
±0.4
±0.4
±0.4
±0.7
Dissipation factor tan
δ
Test voltage between terminals
≤
1.0% at 1 kHz
The 100% screening factory test is carried
out at 2150 VDC. The voltage level is selected
to meet the requirements in applicable
equipment standards. All electrical
characteristics are checked after the test.
Tabulated self-resonance frequencies f
0
refer
to 5 mm lead length.
≥
30 mm
+5
–0
mm
Resonance frequency
Insulation resistance
C
≤
0.33 µF:
≥
30 000 MΩ
C > 0.33 µF:
≥
10 000 s
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
1.25 x U
R
VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temp.
3 directions at 2 hours
each, 10–55 Hz at
0.75 mm or 98 m/s
2
No visible damage
No open or short circuit
Vibration
IEC 60068–2–6
Test Fc
Bump
IEC 60068–2–29 1000 bumps at
Test Eb
390 m/s
2
IEC 60068–2–14 Upper and lower rated
Test Na
temperature 5 cycles
EN 132400
No visible damage
No open or short circuit
No visible damage
Change of
temperature
Active
flammability
Passive
flammability
IEC 60384-14 (1993)
EN 132400
UL1414
Enclosure material of
UL94V–0 flammability class
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
Humidity
135
PHE830
ARTICLE TABLE
Quantity per package
reel
Bulk Tray
taped
pcs
pcs
pcs
800
800
800
800
800
800
800
600
600
400
400
300
234
234
186
168
253
216
198
153
126
108
119
105
600
600
600
600
600
600
600
500
500
400
400
350
Approvals
Weight
g
1.5
1.5
1.5
1.5
1.5
1.7
1.7
2.0
2.0
2.7
4.3
4.3
3.3
3.3
4.5
5.5
8.0
9.0
10.5
14.5
20.0
26.0
21.0
28.0
f
O
MHz
13
11
9.0
7.5
6.5
6.5
5.5
5.5
4.5
4.5
3.9
2.7
4.5
3.9
2.7
2.5
2.0
1.9
1.6
1.3
0.8
0.6
0.7
0.6
Max
dU/dt
V/µs
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Article code
1 st block
PHE830MB5100M
PHE830MB5150M
PHE830MB5220M
PHE830MB5330M
PHE830MX5470M**
PHE830MB5470M
PHE830MX5680M**
PHE830MB5680M
PHE830MX6100M**
PHE830MB6100M
PHE830MB6150M
PHE830MB6220M
PHE830MD6100M
PHE830MD6150M
PHE830MD6220M
PHE830MD6330M
PHE830MD6470M
PHE830MF6470M
PHE830MF6680M
PHE830MF7100M
PHE830MF7150M
PHE830MF7220M
PHE830MR7150M
PHE830MR7220M
Capaci- Max dimensions
tance* in mm
µF
B
H
L
0.010
0.015
0.022
0.033
0.047
0.047
0.068
0.068
0.10
0.10
0.15
0.22
0.10
0.15
0.22
0.33
0.47
0.47
0.68
1.0
1.5
2.2
1.5
2.2
5.5
5.5
5.5
5.5
5.5
5.5
5.5
6.5
6.5
7.5
8.5
9.5
6.5
6.5
8.0
9.0
11.0
10.5
11.5
14.5
17.5
21.0
10.5
10.5
10.5
10.5
10.5
12.5
12.5
12.5
12.5
14.5
16.0
17.5
14.5
14.5
16.0
18.5
21.5
20.5
22.5
24.5
28.0
30.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
26.0
26.0
26.0
26.0
26.0
31.5
31.5
31.5
31.5
31.5
p
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
22.5
22.5
22.5
22.5
22.5
27.5
27.5
27.5
27.5
27.5
15.0 26.0
16.5 32.0
41.0 37.5
41.0 37.5
√ √ √ √
√ √ √ √
* The complete serie includes C values according to the E12 series. Details on request. ** Only ±20% tolerance
APPROVALS/REFERENCE DOCUMENTS
Country
S
= Sweden
Specification
EN 132400
EN 132400
UL 1283 (U
R
= 250 VAC)
UL 1414 (U
R
= 125 VAC)
C 22.2 No. 8 (U
R
= 250 VAC)
Approval reference
9707087-01,
9713122-01
101315, 101316
E 100117
E 73869
53108
•
•
•
•
•
•
•
•
•
•
MARKING
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
X2
Approval marks
Manufacturing code (year, month)
IEC climatic category
Passive flammability class
VDE = Germany
UL = USA
CSA = Canada
ORDERING INFORMATION
Article code
1st block
See article table
Pos. 13 Capacitance tolerance code:
M = ± 20% standard
K = ± 10% option
2nd block
If not standard lead length,
add R06 – R50 in pos. 14–16)
For reel taped, add 17T0 or 17T1
in pos. 15-18. For packing on trays
(6 mm lead length), add L2 in pos. 17–18.
M
R
14
0
6
17 18 19 20
PACKING
The box dimensions for bulk packaging are
245 x 145 x 78 mm. Quantity/package as per
article table.
Reels with taped capacitors are packed
10 in a box with dimension 370 x 370 x
560 mm. Quantity/reel according to article
table.The standard quantity/reel is for 360
mm reel. If 500 mm reel is required, it must
be specified when ordering and the
quantity is 2 x the given quantity.
P H E 8 3 0 M B 5 3
1 2
3 4 5 6 7
3
0
8 9 10 11 12 13
15 16
136