Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Commercial Status
Range of product
Product or component
type
Component name
Time delay type
Time delay range
[Us] rated supply
voltage
Sale per indivisible
quantity
Commercialised
Zelio Time
Optimum industrial timing relay
RE8
A
20...1800 s
24 V AC/DC, 50/60 Hz
110...240 V AC, 50/60 Hz
10
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Discrete output type
Contacts material
Width pitch dimension
Voltage range
Connections - terminals
Tightening torque
Setting accuracy of time delay
Repeat accuracy
Voltage drift
Temperature drift
Minimum pulse duration
Reset time
Maximum switching voltage
Mechanical durability
[Ith] conventional free air thermal current
[Ie] rated operational current
Relay
90/10 silver nickel contacts
0.89 in (22.5 mm)
0.9...1.1 Us
Screw terminals 2 x 2.5 mm², flexible cable without cable end
Screw terminals 2 x 1.5 mm², flexible cable with cable end
5.31...9.73 lbf.in (0.6...1.1 N.m)
+/- 20 % of full scale
<1%
< 2.5 %/V
< 0.2 %/°C
26 ms
50 ms
250 V
20000000 cycles
8A
<= 0.2 A at 115 V, DC-13 for 158 °F (70 °C) conforming to VDE 0660
<= 0.2 A at 115 V, DC-13 for 158 °F (70 °C) conforming to IEC 60947-5-1/1991
<= 0.1 A at 250 V, DC-13 for 158 °F (70 °C) conforming to VDE 0660
<= 0.1 A at 250 V, DC-13 for 158 °F (70 °C) conforming to IEC 60947-5-1/1991
<= 3 A at 24 V, AC-15 for 158 °F (70 °C) conforming to VDE 0660
<= 3 A at 24 V, AC-15 for 158 °F (70 °C) conforming to IEC 60947-5-1/1991
<= 2 A at 24 V, DC-13 for 158 °F (70 °C) conforming to VDE 0660
<= 2 A at 24 V, DC-13 for 158 °F (70 °C) conforming to IEC 60947-5-1/1991
10 mA at 12 V
CE
III conforming to IEC 60664-1
300 V conforming to CSA
250 V conforming to IEC
> 0.1 Uc
Any position without derating factor
2 kV conforming to IEC 61000-4-5 level 3
8.5 VA at 240 V
1.8 VA at 110 V
0.7 VA at 24 V
0.5 W at 24 V
(15-16-18)OC_OFF
(A1-B1)CO
ALT
1
Minimum switching capacity
Marking
Overvoltage category
[Ui] rated insulation voltage
Supply disconnection value
Operating position
Surge withstand
Power consumption in VA
Power consumption in W
Terminal description
Feb 28, 2016
Height
Width
Depth
Product weight
3.07 in (78 mm)
0.89 in (22.5 mm)
3.15 in (80 mm)
0.24 lb(US) (0.11 kg)
Environment
Immunity to microbreaks
Standards
Product certifications
3 ms
EN/IEC 61812-1
CSA
GL
UL
-40...185 °F (-40...85 °C)
-4...140 °F (-20...60 °C)
15...85 % 3K3 conforming to IEC 60721-3-3
0.35 mm 10...55 Hz conforming to IEC 60068-2-6
15 gn (duration = 11 ms conforming to IEC 60068-2-27
IP50 (casing)
IP20 (terminals)
3 conforming to IEC 60664-1
2.5 kV
4.8 kV
8 kV in air conforming to IEC 61000-4-2 level 3
6 kV in contact conforming to IEC 61000-4-2 level 3
9.14 V/yd (10 V/m) conforming to IEC 61000-4-3 level 3
2 kV conforming to IEC 61000-4-4 level 3
CISPR 11 group 1 - class A
CISPR 22 - class A
Ambient air temperature for storage
Ambient air temperature for operation
Relative humidity
Vibration resistance
Shock resistance
IP degree of protection
Pollution degree
Dielectric test voltage
Non-dissipating shock wave
Resistance to electrostatic discharge
Resistance to electromagnetic fields
Resistance to fast transients
Disturbance radiated/conducted
Ordering and shipping details
Category
Discount Schedule
GTIN
Nbr. of units in pkg.
Package weight(Lbs)
Product availability
Returnability
Country of origin
22376 - RELAYS-MEASUREMENT(RM4)
CP2
00785901691709
10
0.24
Non-Stock - Not normally stocked in distribution facility
2012年8月28日-30日,华南地区最大、历史最悠久的SMT交流平台NEPCON South China 2012将在深圳会展中心举行。据主办方介绍,来自汽车电子生产制造的企业将会成为NEPCON South China 2012观众招募的新生力量,同时,主办方励展博览集团还将与EDN China共同合办汽车电子专业研讨会,探讨汽车电子领域最新的发展趋势。 当今汽车科技含量越来越高,越来越多...[详细]