RLU4116E
Description
LD-375-70MG
is an Ultra Violet Laser Diode emitting at 375 nm with rated output power of 70 mW in
standard 5.6mm TO package. It features integrated photo diode and ESD protection circuit.
Maximum Ratings
Parameter
Optical Output Power
PD Reverse Voltage
Reverse Current
Operating Temperature
Storage Temperature
Soldering Temperature
Symbol
P
O
V
R (PD)
I
R
T
CASE
T
STG
T
SOLDER
+ 10
- 40
Values
Min.
Max.
85
5
85
+ 40
+ 85
260
Unit
mW
V
mA
°C
°C
°C
Laser Characteristics
(T
Parameter
Emission Wavelength
Optical Output Power
Spectral Width
Threshold Current
Operating Current
Operating Voltage
Beam Divergence (FWHM)
CASE
=
25°C, P
O
= 70 mW)
Values
Typ.
-
2
50
110
5.4
6x19
- 3 / -3
0.9
9x22.5
-
1.2
2.0
75
140
6.0
11x26
3/3
Symbol
λ
peak
P
O
∆λ
Min.
370
Max.
380
70
Unit
nm
mW
nm
mA
mA
V
deg.
deg.
W/A
mA
I
th
I
F
V
F
ӨII x Ө┴
∆Ө
II
/ ∆Ө
┴
η
Beam Pointing Accuracy (FWHM)
Slope Efficiency
Monitor Current*
0.05
0.2
I
m
*Monitor current is short term power reference only. Not guaranteed for accuracy.
www.roithner-laser.com
-1-
29/11/12
Performance Characteristics
Output Power vs. Forward Current
Forward Voltage vs. Forward Current
Output Power vs. Case Temperature
Peak Wavelength vs. Case Temperature
Far Field Pattern
Spectrum
www.roithner-laser.com
-2-
29/11/12
Drawing
Dimensions in mm
Electrical Connection
Lead
Pin 1
Pin 2
Pin 3
Pin 4
Description
LD Anode
LD Cathode
PD Cathode
PD Anode
View from below, dimensions in mm
Mounting Instruction
In order to maintain lifetime and stability of the laser diode it is essential to provide efficient heat
management. Heat dissipation is possible through the base plate only. For long time stable operation
proper contact between laser diode base plate and heat sink is mandatory
www.roithner-laser.com
-3-
29/11/12
Safety Advice
This laser diode emits highly concentrated ultra violet light which can be
hazardous to the human
eye.
This diode is classified as
Class 3B laser product
according to
IEC 60825-1
and
21 CFR Part
1040.10 Safety Standards.
Actual laser light emitted and precautions necessary strongly depend on
mode of operation.
© All Rights Reserved
The above specifications are for reference purpose only and subjected to change without prior notice
www.roithner-laser.com
-4-
29/11/12