Features
Regulated
Converters
Description
•
•
•
•
•
•
4:1 Wide Input Voltage Range
1.6kVDC Isolation
UL Certified
Efficiency up to 91%
Six-Sided Continuous Shield
No Minimum Load Required
DC/DC Converter
RP10-AW
10 Watt
3
1“x1“
Single & Dual
Output
3Y
wa
EAR
The RP10-AW series are wide input voltage range 1”x1” power DC/DC converters. Despite their small
size, the RP10-AW converters are fully specified devices with built-in Class B EMC filters, no minimum
load, 1600VDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are fully pro-
tected against short circuits, overcurrent and overvoltage and can be trimmed over a +/-10% range.
The RP10-AW series will find many uses in applications where board space is at a premium as no
external components are required.
rranty
Selection Guide
Part Number
RP10-243.3SAW
(2,3)
RP10-2405SAW
(2,3)
RP10-2412SAW
(2,3)
RP10-2415SAW
(2,3)
RP10-2424SAW
(2,3)
RP10-483.3SAW
(2,3)
RP10-4805SAW
(2,3)
RP10-4812SAW
(2,3)
RP10-4815SAW
(2,3)
RP10-4824SAW
(2,3)
RP10-2405DAW
(2,3)
RP10-2412DAW
(2,3)
RP10-2415DAW
(2,3)
RP10-4805DAW
(2,3)
RP10-4812DAW
(2,3)
RP10-4815DAW
(2,3)
Input
Voltage Range
[VDC]
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
9-36
9-36
9-36
18-75
18-75
18-75
Output
Voltage
[VDC]
3.3
5
12
15
24
3.3
5
12
15
24
±5
±12
±15
±5
±12
±15
Output
Current
[mA]
3000
2000
830
670
416
3000
2000
830
670
416
±1000
±416
±333
±1000
±416
±333
Input
(1)
Efficiency
(1)
Current
typ.
[mA]
[%]
485
85
479
87
461
90
460
91
462
90
243
85
239
87
231
90
233
90
231
90
479
87
467
89
468
89
239
87
234
89
234
89
Max. Capacitive
Load
[µF]
3500
2500
430
350
125
3500
2500
430
350
125
±1440
±250
±180
±1440
±250
±180
E196683
UL60950-1 Certified
Notes:
Note1: at nominal input voltage and full load.
Model Numbering
RP10-__ __ _AW/_ _
Input Voltage
Output Voltage
Single
or
Dual
Ordering Examples
RP10-2405SAW/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted
RP10-4805DAW/XC-HC = 48V Input, ±5V Output, without CTRL pin, with fitted Heat-sink
RP10-2415SAW/N = 24V Input, 5V Output, Negative Logic CTRL pin and Trim pin fitted
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) and trim pin
add suffix “N” instead for negative logic (0=ON, 1=OFF) and trim pin
or add suffix “XC” instead for no CTRL pin
Note3: add suffix “-HC” for premounted Heat-sink with clamps
Package
(3)
CTRL Logic
(2)
www.recom-power.com
REV.: 3/2017
PD-1
RP10-AW
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Series
Condition
nom. Vin = 24V
nom. Vin = 48V
Vin = 24V
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Min.
9VDC
18VDC
Typ.
24VDC
48VDC
8VDC
Max.
36VDC
75VDC
9VDC
18VDC
Under Voltage Lockout (UVLO)
Vin = 48V
Internal Input Filter
Input Reflected Ripple Current
Input Surge Voltage
Start-up time
Operating Frequency Range
Minimum Load
Ripple and Noise
16VDC
Pi-Type
30mAp-p
50VDC
100VDC
30ms
30ms
297kHz
330kHz
40mVp-p
60mVp-p
60mVp-p
Open or 3.0 < Vr < 15VDC
Short or 0 < Vr < 1.2VDC
Short or 0 < Vr < 1.2VDC
Open or 3.0 < Vr < 15VDC
-0.5 mA
1.0mA
363kHz
0%
nominal Vin and full load
Vin = 24V, 1s max.
Vin = 48V, 1s max.
Power up
Remote ON/OFF
of full load
measured by 20MHz bandwidth 3.3Vout, 5Vout
with a 10µF/25V X7R 1206 MLCC 12Vout, 15Vout
measured by 20MHz bandwidth
24Vout
with a 1µF/50V X7R 1206 MLCC
DC-DC ON
DC-DC OFF
DC-DC ON
Negative Logic
DC-DC OFF
Positive Logic
ON/OFF Control
Input Current of CTRL Pin
RP10-2405SAW
Efficiency vs. Output Current
100
95
90
85
80
75
70
65
60
55
50
45
40
10
100
95
90
Efficiency vs. Input Voltage
Efficiency [%]
Efficiency [%]
9Vin
24Vin
36Vin
20
30
40
50
60
70
80
90
100
85
80
75
70
65
60
9
14
19
24
29
34
Output Current [%]
Input Voltage [V]
PD-2
REV.: 3/2017
www.recom-power.com
RP10-AW
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
REGULATION
Parameter
Output Voltage Accuracy
Output Trimming
Line Voltage Regulation
Single
low line to high line
0% to 100% load
Load Voltage Regulation
10% to 90% load
Cross Regulation
Transient Response
3.3Vout, 12Vout
Others
Single
Dual
Single
Dual
Single
Dual
Series
Condition
Value
±1%
±10%
-10% to +20%
±0.2%
±0.5%
±0.2%
±1.0%
±0.1%
±0.8%
±5%
250µs typ.
asymmetrical 25%<>100% load
25% load step change
External Output Trimming
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using
external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for
chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to
work out the resistor required or use a variable resistor to set the output voltage.
TRIM UP
6
RU
5
TRIM DOWN
5
RD
4
RP10-xx3.3SAW
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
3.333
385.07
1
3.267
116.72
2
3.366
191.51
2
3.234
54.78
3
3.399
126.99
3
3.201
34.13
4
3.432
94.73
4
3.168
23.81
5
3.465
75.37
5
3.135
17.62
6
3.498
62.47
6
3.102
13.49
7
3.531
53.25
7
3.069
10.54
8
3.564
46.34
8
3.036
8.32
9
3.597
40.96
9
3.003
6.60
10
3.63
36.66
10
2.97
5.23
%
Volts
kOhms
%
Volts
kOhms
RP10-xx05SAW
Trim up
Vout =
R
U
=
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
5.05
253.45
11
5.55
21.18
1
4.95
248.34
2
5.10
125.70
12
5.60
19.24
2
4.90
120.59
3
5.15
83.12
13
5.65
17.60
3
4.85
78.01
4
5.20
61.82
14
5.70
16.20
4
4.80
56.71
5
5.25
49.05
15
5.75
14.98
5
4.75
43.94
6
5.30
40.53
16
5.80
13.92
6
4.70
35.42
7
5.35
34.45
17
5.85
12.98
7
4.65
29.34
8
5.4
29.89
18
5.90
12.14
8
4.60
24.78
9
5.45
26.34
19
5.95
11.39
9
4.55
21.23
10
5.50
23.50
20
6.00
10.73
10
4.50
18.39
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
continued on next page
www.recom-power.com
REV.: 3/2017
PD-3
RP10-AW
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP10-xx12SAW
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
Trim up
Vout =
R
U
=
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
12.12
203.22
1
11.88
776.56
1
15.15
161.56
11
16.65
10.04
1
14.85
818.22
2
12.24
99.06
2
11.76
380.72
2
15.30
78.22
12
16.80
8.78
2
14.70
401.56
3
12.36
64.33
3
11.64
248.78
3
15.45
50.45
13
16.95
7.71
3
14.55
262.67
4
12.48
46.97
4
11.52
182.81
4
15.60
36.56
14
17.10
6.80
4
14.40
193.22
5
12.60
36.56
5
11.40
143.22
5
15.75
28.22
15
17.25
6.00
5
14.25
151.56
6
12.72
29.61
6
11.28
116.83
6
15.90
22.67
16
17.40
5.31
6
14.10
123.78
7
12.84
24.65
7
11.16
97.98
7
16.05
18.70
17
17.55
4.69
7
13.95
103.94
8
12.96
20.93
8
11.04
83.85
8
16.20
15.72
18
17.70
4.15
8
13.80
89.06
9
13.08
18.04
9
10.92
72.85
9
16.35
13.41
19
17.85
3.66
9
13.65
77.48
10
13.20
15.72
10
10.8
64.06
10
16.50
11.56
20
18.00
3.22
10
13.50
68.22
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
Series
RP10-xx15SAW
RP10-xx24SAW
Trim up
Vout =
R
U
=
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
24.24
570.33
11
26.64
40.03
1
23.76
4947.67
2
24.48
278.67
12
26.88
35.61
2
23.52
2439.33
3
24.72
181.44
13
27.12
31.87
3
23.28
1603.22
4
24.96
132.83
14
27.36
28.67
4
23.04
1185.17
5
25.20
13.67
15
27.60
25.89
5
22.80
934.33
6
25.44
84.22
16
27.84
23.46
6
22.56
767.11
7
25.68
70.33
17
28.08
21.31
7
22.32
647.67
8
25.92
59.92
18
28.32
19.41
8
22.08
558.08
9
26.16
51.82
19
28.56
17.70
9
21.84
488.41
10
26.40
45.33
20
28.80
16.17
10
21.60
432.67
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
PROTECTION
Parameter
Short Circuit Protection (SCP)
3.3Vout
5Vout
Zener Diode Clamp 12Vout
15Vout
24Vout
Hiccup Mode
I/P to O/P
I/P (O/P) to case
tested with 500VDC
Condition
Value
continuous, automatic recovery
3.7 - 5.4V
6.3 - 7.4V
13.5 - 19.6V
18.3 - 22.0V
29.1 - 32.5V
150% typ.
1.6kVDC/1 minute
1.0kVDC/1 minute
1GΩ min.
1500pF max.
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Notes:
Note4: This power module is not internally fused. An input line fuse must always be used.
PD-4
REV.: 3/2017
www.recom-power.com
RP10-AW
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
MTBF
MIL-HDBK-217F
Natural convection (20LFM) without Heat-sink
Natural convection (20LFM) with Heat-sink
Series
Condition
without derating
with derating
Value
-40°C to +78°C
-40°C to +100°C
+105°C
±0.02%/°C max.
18.2°C/W
15.8°C/W
5% - 95% RH
MIL-STD-810F
MIL-STD-810F
3376 x 10
3
hours
Derating Graph
(5)
RP10-2405SAW
100
80
60
40
20
0
-40
100
80
60
40
20
0
-40
RP10-2405SAW-HC
Output Power [%]
-20
0
20
40
60 78 80
100
Output Power [%]
-20
0
20
40
60
80
81
100
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note5: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
Report / File Number
E196683
Standard
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
(6)
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
(7)
Surge Immunity
(7)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Condition
with external filter
Air ±8kV and Contact ± 6kV
10 V/m
±2kV
±1kV
3 Vr.m.s
100A/m continuous, 1000A/m 1s
Standard / Criterion
EN55022, Class A or B
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
Notes:
Note6: The standard modules meet EMI Class A without external components and Class B with external components; see filter suggestions
below. RP10-2405SAW meets EMI Class B without external components.
Note7: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Recom
suggests: Nippon chemi-con KY series, 220µF/100V.
continued on next page
www.recom-power.com
REV.: 3/2017
PD-5