首页 > 器件类别 > 半导体 > 电源管理

RSO-1233D-H3

Isolated DC/DC Converters 1W DC/DC 3kV REG 2:1 9-18Vin +/-3.3Vout

器件类别:半导体    电源管理   

厂商名称:RECOM Power GmbH

厂商官网:https://www.recom-power.com/

下载文档
RSO-1233D-H3 在线购买

供应商:

器件:RSO-1233D-H3

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
产品种类
Product Category
Isolated DC/DC Converters
制造商
Manufacturer
RECOM Power GmbH
RoHS
Details
Number of Outputs
2 Output
Output Power
1 W
Input Voltage
9 V to 18 V
Output Voltage-Channel 1
- 3.3 V
Output Voltage-Channel 2
3.3 V
Isolation Voltage
3 kV
长度
Length
21.844 mm
宽度
Width
9.144 mm
高度
Height
11.176 mm
系列
Packaging
Tube
产品
Product
Isolated
工厂包装数量
Factory Pack Quantity
22
单位重量
Unit Weight
0.165788 oz
文档预览
Features
Regulated
Converters
2:1 and 4:1 Wide Input Voltage Ranges
1kVDC, 2kVD or 3kVDC Isolation
UL94V-0 Package Material
Certified for Medical Applications
Continuous Short Circuit Protection
Low Noise
No External Capacitor needed
Efficiency to 83 %
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description
High-power-density, an industrial temperature range of -40°C to +85°C and extra features like
On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated
industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option "/H2"
or "/H3" in which case it is also ideal for medical applications which additionally require EN-60601-
1 certification. The standard version offers 2:1 input voltage range, while the “Z” version features 4:1
input voltage range, which includes an input voltage range covering both 5V and 12V supplies.
Selection Guide
Input
Rated Output Output Current Efficiency
Max
Voltage Range
Voltage
typ.
Capacitive
SIP8
(VDC)
(VDC)
(mA)
(%)
Load
(1)
RSO-xx3.3S*
4.5-9**, 9-18
3.3
300
68-72
3300µF
18-36, 36-72
70
RSO-xx05S*
4.5-9**, 9-18
5
200
73-75
1200µF
18-36, 36-72
75-78
RSO-xx09S*
4.5-9**, 9-18
9
111
74-78
680µF
18-36, 36-72
78-81
RSO-xx12S*
4.5-9**, 9-18
12
83
75-80
680µF
18-36, 36-72
80-83
RSO-xx15S*
4.5-9**, 9-18
15
67
75-80
680µF
18-36, 36-72
80-83
RSO-xx3.3D*
4.5-9**, 9-18
±3.3
±150
68-72
±1500µF
18-36, 36-72
70
RSO-xx05D*
4.5-9**, 9-18
±5
±100
73-75
±470µF
18-36, 36-72
75-76
RSO-xx09D*
4.5-9**, 9-18
±9
±56
74-78
±470µF
18-36, 36-72
78
RSO-xx12D*
4.5-9**, 9-18
±12
±42
75-79
±330µF
18-36, 36-72
79-80
RSO-xx15D*
4.5-9**, 9-18
±15
±34
75-79
±330µF
18-36, 36-72
79-80
RSO-xx3.3SZ*
9-36
3.3
300
68-70
3300µF
18-72
70
RSO-xx05SZ*
4.5-18**, 9-36
5
200
73-78
1200µF
18-72
75
RSO-xx09SZ*
4.5-18**, 9-36
9
111
75-81
680µF
18-72
78
RSO-xx12SZ*
4.5-18**, 9-36
12
83
77-83
680µF
18-72
80
RSO-xx15SZ*
4.5-18**, 9-36
15
67
78-83
680µF
18-72
80
RSO-xx3.3DZ*
9-36
±3.3
±150
70-74
±1500µF
18-72
70
RSO-xx05DZ*
4.5-18**, 9-36
±5
±100
73-77
±470µF
18-72
75
RSO-xx09DZ*
4.5-18**, 9-36
±9
±56
74-78
±470µF
18-72
78
RSO-xx12DZ*
4.5-18**, 9-36
±12
±42
75-80
±330µF
18-72
80
RSO-xx15DZ*
4.5-18**, 9-36
±15
±34
75-80
±330µF
18-72
80
No suffix is standard isolation (1kVDC) e.g, RSO-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3
** derate to 75% if Vin<5V, 12V 4:1 input also requires an external 10µF input capacitor.
www.recom-power.com
REV: 2/2017
Part Number
1 Watt
SIP8 Isolated
Single
&
Dual
Output
RSO
Derating-Graph
(Ambient Temperature)
100
4:1
2:1
Output Power (%)
80
60
40
30
20
0
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
2:1 Input
(RS0-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RSO-SZ/DZ)
xx = 4.5-18Vin = 12
xx = 9-36Vin = 24
xx = 18-72Vin = 48
E-123
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Minimum Load
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
CTRL Pin drive current /see Notes)
Quiescent Input Current when Converter is OFF
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
RSO-05xxS_D, SZ_DZ
RSO-12xxS_D, SZ_DZ
RSO-24xxS_D, SZ_DZ
RSO-48xxS_D, SZ_DZ
2:1
4:1
2:1
4:1
2:1
4:1
2:1 and 4:1
±2% typ.
±0.2% max.
±0.5% max.
±0.4% max.
±0.5% typ.
10%
(2)
50mVp-p max.
200kHz min. / 500kHz max.
100kHz min. / 800kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
3mA typ, 6mA max.
10mA max.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max.
>1GΩ min.
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
4.7g
22 pcs per Tube
Detailed Information see
Application Notes chapter "MTBF"
RSO-S_D(Z)
Series
Specifications
(Core Operating Area)
measured at TA = 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified
RSO-24xxS
Efficiency / Load
100
80
60
40
2412
2409
2405
2415
Efficiency %
20
0
0%
20%
40%
60%
80%
100%
Total Output current (%)
RSO-1205SZ
Efficiency / Load
100
80
60
40
RS0
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
1205SZ
Efficiency %
20
0
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
EN General Safety
EN Medical Safety
UL General Safety
Notes
Note 1:
Note 2:
Report: SPCLVD1605077-10
Report: MDD1205098-3 + RM1205098-3
Report: E224736-A34
0%
20%
40%
60%
80%
100%
Total Output current (%)
}
using MIL-HDBK 217F
using MIL-HDBK 217F
1685 x 10
3
hours
254 x 10 hours
EN60950-1, AM2:2013
3
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
IEC/EN 60601-1 3rd Edition
UL60950-1, 2nd Edition 2014
Medical Report + ISO14971 Risk Assessment
CSA C22.2 60950-1-07, 2nd Edition 2014
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
E-124
REV: 2/2017
www.recom-power.com
ECONOLINE
DC/DC-Converter
Typical Application
+Vin
10µF input MLCC
capacitor
required for
RSO-12xxSZ_DZ
only.
-Vin
Vin-
Fuse
Vin+
Vout+
RSO-S_D(Z)
Series
+Vout
RSO
Vout-
-Vout
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
11.10
4.1
Single Output
Dual Output
RECOM
R S O - x x x x S _ D
0.50±0.05
****
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
RECOM
RSO-xxxxS
****
1 2 3
5 6 7 8
RECOM
RSO-xxxxD
****
1 2 3
5 6 7 8
Recommended Footprint Details
1.0ø+0.15/–0
Pin Connections
Pin #
1
2
3
5
6
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.25
Bottom View
2.54
3.20
2.0
2.54
Top View
7
8
CTRL Examples:
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode.
When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is
ON. There is no allowed low state for this pin.
NC = No Connection
NC* = NC, but no external Connection allowed.
RSO
ON/OFF CONTROL
V+
V
IN
+
ON
OFF
V
IN
-
10K
-Vin
+Vin
+Vout
LEAVE OPEN
CTRL
3
5~12
1N4148
68
CTRL
-Vout
FET.
V-
Remote ON/OFF
ON: open or high impedance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
I
= 3V
O = 0.5V or GND
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 2/2017
E-125
查看更多>
热门器件
热门资源推荐
器件捷径:
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF EG EH EI EJ EK EL EM EN EO EP EQ ER ES ET EU EV EW EX EY EZ F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF FG FH FI FJ FK FL FM FN FO FP FQ FR FS FT FU FV FW FX FY FZ G0 G1 G2 G3 G4 G5 G6 G7 G8 G9 GA GB GC GD GE GF GG GH GI GJ GK GL GM GN GO GP GQ GR GS GT GU GV GW GX GZ H0 H1 H2 H3 H4 H5 H6 H7 H8 HA HB HC HD HE HF HG HH HI HJ HK HL HM HN HO HP HQ HR HS HT HU HV HW HX HY HZ I1 I2 I3 I4 I5 I6 I7 IA IB IC ID IE IF IG IH II IK IL IM IN IO IP IQ IR IS IT IU IV IW IX J0 J1 J2 J6 J7 JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ JR JS JT JV JW JX JZ K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 KA KB KC KD KE KF KG KH KI KJ KK KL KM KN KO KP KQ KR KS KT KU KV KW KX KY KZ
需要登录后才可以下载。