1. Measured at 100~240 Vac input, full load, 20 MHz bandwidth oscilloscope, output terminated with a 10 µF aluminum electrolytic and 0.1 µF ceramic capacitor.
2. CoC Tier 2 compliant
PART NUMBER KEY
SDI40
-
XX
- U
X
-
XXX
-
CXX
Base Number
Output Voltage
AC Inlet Type:
IEC320/C14
Reserved for Custom
Configurations
DC Plug Type:
XXX = See output plug options
on page 5 for more details
ST = Stripped and Tinned
Input Cable:
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
SDI40-U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
04/23/2018
│
page
2 of 6
INPUT
parameter
voltage
frequency
current
leakage current
no load power consumption
conditions/description
min
90
47
typ
max
264
63
1
3.5
0.075
units
Vac
Hz
A
mA
W
OUTPUT
parameter
load regulation
conditions/description
min
typ
±5
max
units
%
PROTECTIONS
parameter
over voltage protection
conditions/description
12
15
19
24
12
15
19
24
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
output
output
output
output
output
output
output
output
model
model
model
model
model
model
model
model
min
typ
max
16
22
27
32
5
4.3
5
2.8
units
Vdc
Vdc
Vdc
Vdc
A
A
A
A
over current protection
short circuit protection
output shut down, auto recovery
SAFETY & COMPLIANCE
parameter
isolation voltage
isolation resistance
safety approvals
EMI/EMC
RoHS
conditions/description
input to output at 10 mA for 1 minute
input to output at 500 Vdc
UL/cUL, GS, PSE
FCC Part 15B Class B, CE
2011/65/EU
100
min
typ
1,500
2,121
max
units
Vac
Vdc
MΩ
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
storage humidity
non-condensing
non-condensing
conditions/description
min
0
-10
20
10
typ
max
40
70
80
90
units
°C
°C
%
%
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
SDI40-U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
04/23/2018
│
page
3 of 6
MECHANICAL
parameter
dimensions
inlet plug
weight
conditions/description
111 x 52 x 32.3
IEC320/C14
without AC cord
with AC cord
247
396
g
g
min
typ
max
units
mm
MECHANICAL DRAWING
units: mm
LED
Note: 1. LED indicator is not present on 24 Vdc output model.