Note: Please consult us about other coil voltages.
TYPES
Contact arrangement
Nominal coil voltage
12 V DC
24 V DC
48 V DC
12 V DC
24 V DC
48 V DC
12 V DC
24 V DC
48 V DC
12 V DC
24 V DC
48 V DC
12 V DC
24 V DC
48 V DC
Without LED indication
Part No.
SFS2-DC12V
SFS2-DC24V
SFS2-DC48V
SFS3-DC12V
SFS3-DC24V
SFS3-DC48V
SFS4-DC12V
SFS4-DC24V
SFS4-DC48V
SFS5-DC12V
SFS5-DC24V
SFS5-DC48V
SFS6-DC12V
SFS6-DC24V
SFS6-DC48V
With LED indication
Part No.
SFS2-L-DC12V
SFS2-L-DC24V
SFS2-L-DC48V
SFS3-L-DC12V
SFS3-L-DC24V
SFS3-L-DC48V
SFS4-L-DC12V
SFS4-L-DC24V
SFS4-L-DC48V
SFS5-L-DC12V
SFS5-L-DC24V
SFS5-L-DC48V
SFS6-L-DC12V
SFS6-L-DC24V
SFS6-L-DC48V
2 Form A 2 Form B
4-poles
3 Form A 1 Form B
4 Form A 2 Form B
6-poles
5 Form A 1 Form B
3 Form A 3 Form B
Standard packing: Carton: 50 pcs.; Case: 200 pcs.
* For sockets and terminal sockets.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB119E 201201-T
SFS
RATING
1. Coil data
Contact arrangement
Nominal coil
voltage
12V DC
2 Form A 2 Form B
4-poles
3 Form A 1 Form B
24V DC
48V DC
12V DC
24V DC
48V DC
4 Form A 2 Form B
12V DC
24V DC
48V DC
6-poles
5 Form A 1 Form B
12V DC
24V DC
48V DC
3 Form A 3 Form B
12V DC
24V DC
48V DC
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Pick-up voltage
(at 20°C
68°F)
Drop-out voltage
(at 20°C
68°F)
Nominal
operating current
[±10%]
(at 20°C
68°F)
30mA
15mA
7.5mA
30mA
15mA
7.5mA
41.7mA
20.8mA
10.4mA
41.7mA
20.8mA
10.4mA
41.7mA
20.8mA
10.4mA
Coil resistance
[±10%]
(at 20°C
68°F)
400Ω
1,600Ω
6,400Ω
400Ω
1,600Ω
6,400Ω
288Ω
1,152Ω
4,608Ω
288Ω
1,152Ω
4,608Ω
288Ω
1,152Ω
4,608Ω
Approx. 500mW
110%V of
nominal voltage
Approx. 360mW
Nominal
operating power
(at 20°C
68°F)
Max. applied
voltage
(at 20°C
68°F)
Note: The nominal operating current will increase by approximately 2mA due to the LED on the LED indication type.
2. Specifications (relay)
Characteristics
Item
Contact arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*
1
Nominal operating power
Insulation resistance (Initial)
Between open contacts
Specifications
4-pole
6-pole
2 Form A 2 Form B 3 Form A 1 Form B 4 Form A 2 Form B 5 Form A 1 Form B 3 Form A 3 Form B
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Au flashed AgSnO
2
type
6A 250V AC, 6A 30V DC
1,500VA, 180W
250V AC, 125V DC
6 A (Reduce by 0.1 A/°C for temperatures 70 to 85°C
158 to 185°F)
1mA 5V DC
360mW
500mW
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,500 Vrms for 1 min. (Detection current: 10mA)
2,500 Vrms for 1 min. (Detection current: 10mA);
2,500 Vrms for 1 min.
7-8/11-12 between open contacts
(Detection current: 10mA);
9-10/13-14 between open contacts
7-8/9-10 between open contacts
11-12/13-14 between open contacts
4,000 Vrms for 1 min.
4,000 Vrms for 1 min. (Detection current: 10mA);
(Detection current: 10mA);
3-4/5-6 between open contacts
3-4/5-6 between open contacts
3-4/7-8 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
5-6/9-10 between open contacts
7-8/9-10 between open contacts
4,000 Vrms for 1min (Detection current: 10mA)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time)
Max. 8ms (Nominal coil voltage applied to the coil, excluding contact bounce time) (without diode)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time) (without diode)
Min. 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 10
7
(at 180 times/min.)
250 V AC 6 A resistive load: Min. 10
5
(at 20 times/min.)
30 V DC 6 A resistive load: Min. 10
5
(at 20 times/min.)
250 V AC 1 A resistive load: Min. 5×10
5
(at 30 times/min.)
30 V DC 1 A resistive load: Min. 5×10
5
(at 30 times/min.)
[AC 15] 240 V AC 2 A inductive load: Min. 10
5
(at 20 times/min., cosϕ = 0.3)
[DC 13] 24 V DC 1 A inductive load: Min. 10
5
(at 20 times/min., L/R = 48 ms)
Ambient temperature: –40°C to +85°C
–40°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 20 g
.71 oz
Approx. 23 g
.81 oz
Contact
Rating
Electrical
characteristics
Breakdown
voltage
(Initial)
Between contact sets
Between contact and coil
Operate time (at 20°C
68°F)
Response time (at 20°C
68°F)*
2
Release time (at 20°C
68°F)
Mechanical
characteristics
Shock
resistance
Vibration
resistance
Mechanical
Functional
Destructive
Functional
Destructive
Expected life
Electrical
Conditions
Unit weight
Conditions for operation, transport and
storage*
3
Max. Operating speed
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Response time is the time after the coil voltage turns off until the time when “a” contact turns off.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB119E 201201-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
SFS
REFERENCE DATA
1. Operate/response/release time
Tested sample: SFS4-DC24V (4 Form A/2 Form B),
20pcs. (a contacts: 80, b contacts: 40)
2. Coil temperature rise
Tested sample: SFS4-DC24V (4 Form A/2 Form B),
3pcs.
Measured portion: Inside the coil
Ambient temperature: Room temperature
(27°C
80.6°F),
70°C
158°F,
85°C
185°F
50
3. Malfunctional shock
Tested sample: SFS4-DC24V (4 Form A/2 Form B),
3pcs.
50
40
No. of contacts
Temperature rise,
°C
Operate time
Release time
Response time
Z
Z'
X
X'
40
Y
Y'
Deenergized condition
Energized condition
Y
200m/s
2
Z
200m/s
2
30
30
X
200m/s
2
20
20
10
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Time, ms
0
90
100
0A Room temperature
6A Room temperature
0A 70°C
6A 70°C
0A 85°C
4.5A 85°C
110
120
130
Coil applied voltage, %V
200m/s
2
Z'
200m/s
2
Y'
200m/s
2
X'
4. Max, switching capacity
10
8
7
Contact current, A
6
5
4
3
2
AC resistive load
DC resistive load
1
0.7
0.5
0.3
0.2
0.1
10
20 30
50 70 100 200 300 500
125 250
Contact voltage, V
1000
Other contact gaps when contacts are welded
Sample: SFS4-DC24V (4 Form A/2 Form B)
The table below shows the state of the other contacts.
In case of form “NO” contact weld the coil applied voltage is 0 V.
In case of form “NC” contact weld the coil applied voltage is nominal.
3-4 (NC)
3-4 (NC)
5-6 (NC)
7-8 (NO)
9-10 (NO)
11-12 (NO)
13-14 (NO)
>0.5
>0.5
>0.5
>0.5
>0.5
>0.5
>0.5
>0.5
5-6 (NC)
State of other contacts
7-8 (NO)
9-10 (NO)
>0.5
>0.5
>0.5
>0.5
11-12 (NO)
>0.5
>0.5
13-14 (NO)
>0.5
>0.5
Welded contact No.
>0.5: contact gap is kept at min. 0.5 mm
.020inch
Empty cells: either ON or OFF
Note: Contact gaps are shown at the initial state.
If the contact transfer is caused by load switching, it is necessary to check the actual loading.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB119E 201201-T
SFS
DIMENSIONS
(mm
inch)
CAD Data
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e
1. 4-pole (2 Form A 2 Form B, 3 Form A 1 Form B)
External dimensions
Max. 40
Max. 1.575
Max. 13
Max. .512
(1.83)
(.072)
3.5
.138
Max. 24
Max. .945
13.97
.550
5.08
.200
5.08
.200
11.43
.450
PC board pattern (Bottom view)
10.16
.400
10-1.4
.055
dia.
Tolerance:
±0.1
±.004
1.83
.072
1.0
.039
10.16
.400
13.97
.550
5.08
.200
0.5
.020
5.08
.200
11.43
.450
General tolerance:
±0.3
±.012
Schematic (Bottom view)
1
3
4
7
8
1
3
4
7
8
Standard
2
5
6
9 10
2
5
6
9 10
(2 Form A 2 Form B)
1
3
4
7
8
(3 Form A 1 Form B)
1
3
4
7
8
With LED indication
2
5
6
9 10
2
5
6
9 10
(2 Form A 2 Form B)
(3 Form A 1 Form B)
2. 6-pole (4 Form A 2 Form B, 5 Form A 1 Form B, 3 Form A 3 Form B)