FREE WHEELING DIODE, SNUBBER DIODE, HIGH RELIABILITY
应用
ULTRA FAST SOFT RECOVERY
外壳连接
CATHODE
配置
COMMON CATHODE, 2 ELEMENTS
二极管元件材料
SILICON
二极管类型
RECTIFIER DIODE
JESD-30 代码
R-PSIP-T3
最大非重复峰值正向电流
100 A
元件数量
2
相数
1
端子数量
3
最高工作温度
150 °C
最低工作温度
-55 °C
最大输出电流
10 A
封装主体材料
PLASTIC/EPOXY
封装形状
RECTANGULAR
封装形式
IN-LINE
峰值回流温度(摄氏度)
NOT SPECIFIED
认证状态
Not Qualified
最大重复峰值反向电压
1200 V
最大反向恢复时间
0.045 µs
表面贴装
NO
技术
AVALANCHE
端子形式
THROUGH-HOLE
端子位置
SINGLE
处于峰值回流温度下的最长时间
NOT SPECIFIED
Base Number Matches
1
文档预览
SML10EUZ12BC
Ehanced Ultrafast
Recovery Diode
1200 Volt, 2 x 10 Amp
Back of Case
Cathode
TECHNOLOGY
SML
10EUZ12BC
1 - Anode 1
2 - Com. Cathode
3 - Anode 2
The planar passivated and enhanced ultrafast recovery
diode features a triple charge control action utilising
Semelab’s graded Buffer Zone technology combined with
low emitter efficiency and local lifetime control techniques.
BENEFITS
• Very fast recovery for low switching losses
Common Cathode
• Ultra soft recovery with low EMI generation
1
• High dynamic ruggedness under all conditions
• Low temperature dependency
• Low on-state losses with positive temperature coefficient
• Stable blocking voltage and low leakage current
• Avalanche rated for high reliability circuit operation
2
3
See Package outline for mechanical data and more details
TO247 PACKAGE
Key Parameters
V
R
V
F
I
F
t
rr
(max)
(typ)
(max)
(max)
1200V
3.2V
2 X 10A
35nS
APPLICATIONS
• Freewheeling Diode for IGBTs and MOSFETs
• Uninterruptible Power Supplies UPS
• Switch Mode Power Supplies SMPS
• Inverse and Clamping Diode
• Snubber Diode
• Fast Switching Rectification
ABSOLUTE MAXIMUM RATINGS
(T
case
=
25°C unless otherwise stated)
V
RRM
V
R
I
FAV
I
FSM(surge)
I
FS(surge)
P
D
W
AVL
T
J
,T
STG
Peak Repetitive Reverse Voltage
DC Reverse Blocking Voltage
Average Forward Current @Tc = 85°C
Repetitive Forward Current
Non-Repetitive Forward Current(10msec pulse)
Power Dissipation @Tc = 85°C
Avalanche Energy(L=40mH)
Operating & Storage Junction Temperature
1200V
1200V
10A
25A
100A
35W
10mJ
- 55 to 150°C
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.