The SY10/100E107 offer five 2-input XOR/XNOR gates
and are designed for use in new, high- performance ECL
systems.
The E107 also features a function output, F, which is the
OR of all five XOR gate outputs, while F is the NOR. Both
true and complementary outputs are provided.
BLOCK DIAGRAM
F
F
D
0a
D
0b
D
1a
D
1b
D
2a
D
2b
D
3a
D
3b
D
4a
D
4b
Q
0
Q
0
Q
1
Q
1
Q
2
Q
2
Q
3
Q
3
Q
4
Q
4
PIN NAMES
Pin
D
na
, D
nb
Q
0
-Q
4
Q
0
-Q
4
F
F
V
CCO
Data Inputs
XOR Outputs
XNOR Outputs
OR Output
NOR Output
V
CC
to Output
Function
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
Rev.: F
Amendment: /0
1
Issue Date: March 2006
Micrel, Inc.
SY10E107
SY100E107
PACKAGE/ORDERING INFORMATION
Ordering Information
(1)
D
4b
D
3a
D
4a
V
CCO
NC
Part Number
25 24 23 22 21 20
19
18
17
Package
Type
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
Operating
Range
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Package
Marking
SY10E107JC
SY10E107JC
SY100E107JC
SY100E107JC
SY10E107JZ with
Pb-Free bar-line indicator
SY10E107JZ with
Pb-Free bar-line indicator
SY100E107JZ with
Pb-Free bar-line indicator
SY100E107JZ with
Pb-Free bar-line indicator
Lead
Finish
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Matte-Sn
Matte-Sn
Matte-Sn
Matte-Sn
F
F
SY10E107JC
Q
4
Q
4
V
CC
Q
3
Q
3
Q
2
Q
2
D
3b
D
2a
D
2b
V
EE
D
1a
D
1b
D
0a
26
27
28
1
2
3
4
5
6
7
8
9
10
11
SY10E107JCTR
(2)
SY100E107JC
SY100E107JCTR
(2)
SY10E107JZ
(3)
SY10E107JZTR
(2, 3)
SY100E107JZ
(3)
SY100E107JZTR
(2, 3)
Notes:
PLCC
TOP VIEW
J28-1
16
15
14
13
12
28-Pin PLCC (J28-1)
V
CCO
V
CCO
Q
1
D
0b
Q
0
Q
0
Q
1
1. Contact factory for die availability. Dice are guaranteed at T
A
= 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E107
SY100E107
LOGIC EQUATION
F = (D
0a
⊕
D
0b
) + (D
1a
⊕
D
1b
) + (D
2a
⊕
D
2b
) + (D
3a
⊕
D
3b
) + (D
4a
⊕
D
4b
)
F = Q
0
+ Q
1
+ Q
2
+ Q
3
+ Q
4
DC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
I
IH
I
EE
Parameter
Input HIGH Current
Power Supply Current
10E
100E
—
—
42
42
50
50
—
—
42
42
50
50
—
—
42
48
50
58
—
—
200
T
A
= +25
°
C
—
—
200
T
A
= +85
°
C
Max.
200
Unit
µA
mA
Condition
—
—
—
—
Min. Typ. Max. MIin. Typ.
Max. Min. Typ.
AC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
t
PD
Parameter
Propagation Delay to Output
D to Q
D to F
Within-Device Skew, D to Q
Rise/Fall Time
20% to 80%
Q
F
T
A
= +25
°
C
T
A
= +85
°
C
Max.
600
1000
—
700
700
ps
ps
275
300
450
475
700
700
275
300
450
475
700
700
275
300
450
475
1
—
Unit
ps
250
500
—
410
725
75
600
1000
—
250
500
—
410
725
75
600
1000
—
250
500
—
410
725
75
Condition
—
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
t
skew
t
r
t
f
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10E107
SY100E107
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.