The SY10/100E151 offer 6 edge-triggered, high-speed,
master-slave D-type flip-flops with differential outputs,
designed for use in new, high-performance ECL systems.
The two external clock signals (CLK
1
, CLK
2
) are gated
through a logical OR operation before use as clocking
control for the flip-flops. Data is clocked into the flip-flops
on the rising edge of either CLK
1
or CLK
2
(or both). When
both CLK
1
and CLK
2
are at a logic LOW, data enters the
master and is transferred to the slave when either CLK
1
or
CLK
2
(or both) go HIGH.
The MR (Master Reset) signal operates asynchronously
to make all Q outputs go to a logic LOW.
BLOCK DIAGRAM
D
0
Q
0
R
D
1
D
R
D
2
D
R
D
3
D
R
D
4
D
R
D
5
D
R
CLK
1
CLK
2
M
R
Q
0
Q
1
Q
1
Q
2
Q
2
Q
3
Q
3
Q
4
Q
4
Q
5
Q
5
PIN NAMES
Pin
D
Function
Data Inputs
Clock Inputs
Master Reset
True Outputs
Inverting Outputs
V
CC
to Output
D
0
–D
5
CLK
1
, CLK
2
MR
Q
0
–Q
5
Q
0
–Q
5
V
CCO
M9999-052108
hbwhelp@micrel.com or (408) 955-1690
Rev.: H
Amendment: /0
1
Issue Date: May 2008
Micrel, Inc.
SY10E151
SY100E151
PACKAGE/ORDERING INFORMATION
MR
CLK
2
CLK
1
NC
V
CCO
Q
5
Q
5
Ordering Information
(1)
Part Number
Package
Type
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
Operating
Range
Industrial
Industrial
Commercial
Commercial
Commercial
Commercial
Industrial
Industrial
Commercial
Commercial
Package
Marking
SY10E151JI
SY10E151JI
SY10E151JC
SY10E151JC
SY100E151JC
SY100E151JC
SY10E151JY with
Pb-Free bar-line indicator
SY10E151JY with
Pb-Free bar-line indicator
SY100E151JZ with
Pb-Free bar-line indicator
SY100E151JZ with
Pb-Free bar-line indicator
Lead
Finish
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Matte-Sn
Matte-Sn
Matte-Sn
Matte-Sn
25 24 23 22 21 20 19
SY10E151JI
18
17
D
5
D
4
D
3
V
EE
D
2
D
1
D
0
26
27
28
1
2
3
4
5
6
7
8
9
10 11
Q
4
Q
4
V
CC
Q
3
Q
3
Q
2
Q
2
SY10E151JITR
(2)
SY10E151JC
SY10E151JCTR
(2)
SY100E151JC
SY100E151JCTR
(2)
SY10E151JY
(3)
SY10E151JYTR
(2, 3)
SY100E151JZ
(3)
SY100E151JZTR
(2, 3)
Notes:
PLCC
TOP VIEW
J28-1
16
15
14
13
12
V
CCO
Q
0
Q
1
Q
1
28-Pin PLCC (J28-1)
V
CCO
NC
Q
0
1. Contact factory for die availability. Dice are guaranteed at T
A
= 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-052108
hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E151
SY100E151
TRUTH TABLES
(1)
Asynchronous Operation
Inputs
D
n
X
CLK
1
X
CLK
2
X
MR
H
Output
Q
n
(t + 1)
L
D
n
L
H
L
H
X
X
X
Synchronous Operation
Inputs
CLK
1
u
u
L
L
H
u
L
CLK
2
L
L
u
u
u
H
L
MR
L
L
L
L
L
L
L
Output
Q
n
(t + 1)
L
H
L
H
Q
n
(t)
Q
n
(t)
Q
n
(t)
Note:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don’t Care
t = Time before positive CLK transition
t+1 = Time after positive CLK transition
u = LOW-to-HIGH transition
DC ELECTRICAL CHARACTERISTICS
(1)
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
I
IH
I
EE
Parameter
Input HIGH Current
Power Supply Current
10E
100E
Note:
1. Specification for packaged product only.
T
A
= +25
°
C
150
78
78
—
—
—
—
65
65
150
78
78
T
A
= +85
°
C
Max.
150
78
90
Unit
µA
mA
Condition
—
—
—
—
—
—
65
75
Min. Typ. Max. Min. Typ.
—
—
—
—
65
65
Max. Min. Typ.
AC ELECTRICAL CHARACTERISTICS
(2)
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= 0
°
C
Symbol
f
MAX
t
PD
Parameter
Max. Toggle Frequency
Propagation Delay to Output
CLK
MR
Set-up Time, D
Hold Time, D
Reset Recovery Time
Minimum Pulse Width
CLK, MR
Within-Device Skew
Rise/Fall Time
20% to 80%
1100 1400
475
475
0
350
750
400
—
300
650
650
–175
175
550
—
65
450
—
800
850
—
—
—
—
—
700
T
A
= +25
°
C
1100 1400
475
475
0
350
750
400
—
300
650
650
–175
175
550
—
65
450
—
800
850
—
—
—
—
—
700
T
A
= +85
°
C
Max.
—
800
850
—
—
—
—
—
700
ps
ps
ps
ps
ps
ps
—
—
—
—
1
—
Unit
MHz
ps
475
475
0
350
750
400
—
300
650
650
–175
175
550
—
65
450
Condition
—
—
1100 1400
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
t
S
t
H
t
RR
t
PW
t
skew
t
r
t
f
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Specification for packaged product only.
M9999-052108
hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10E151
SY100E151
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.