首页 > 器件类别 >

T25-A230XF1

SURGE ARRESTER 3-electrode arrester

厂商名称:EPCOS (TDK)

下载文档
文档预览
Surge arrester
3-electrode arrester
Series/Type:
Ordering code:
Version/Date:
Version:
T25-A230XF1
B88069X8630xxxx
a)
Issue 07 / 2007-10-18
01
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Identification/Classification 2:
(header 2 + bottom left header bar)
Ordering code:
(top right header bar)
Series/Type:
(top right header bar)
Preliminary data (optional):
(if necessary)
Department:
Date:
KB AB E / KB AB PM
Issue 07 / 2007-10-18
Surge arrester
3-electrode arrester
B88069X8630xxxx
T25-A230XF1
a)
©
EPCOS AG 2007. Reproduction, publication and dissemination of this document, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Surge arrester
3-electrode arrester
B88069X8630xxxx
a)
T25-A230XF1
Features
Standard size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
Reliable failsafe device
RoHS-compatible
Electrical specifications
DC spark-over voltage
1) 2) 4)
Applications
Branch exchange (MDF)
Line protection
Station protection
230
±
20
< 400
< 350
< 450
< 400
10
50
20
25
5
200
> 10
< 1.5
< 0.2
~ 35
~1
~ 200
~2
-40 ... +90
40/ 90/ 21
230 YY O
230
YY
O
- Nominal voltage
- Year of production
- Non radioactive
V
%
V
V
V
V
A
A
kA
kA
kA
A
pF
µs
V
A
V
g
°C
Impulse spark-over voltage
4)
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs
- for 99 % of measured values
- typical values of distribution
50 Hz, 1 s
5)
50 Hz, 0.18 s (9 cycles)
5)
8/20 µs
5)
8/20 µs
5)
10/350 µs
5)
10/1000 µs
5)
Service life
10 operations
1 operation
10 operations
[5x (+) & 5x (-)]
1 operation
1 operation
300 operations
Insulation resistance at 100 V
dc 4)
Capacitance at 1 MHz
4)
Transverse delay time
3)
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Storage temperature
Climatic category (IEC 60068-1)
Marking, blue negative
KB AB E / KB AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 4
Issue 07 / 2007-10-18
Surge arrester
3-electrode arrester
B88069X8630xxxx
a)
T25-A230XF1
a)
xxxx = B102 (100 pcs. on tray)
B502 (500 pcs. on tray)
1)
2)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
3)
Test according to ITU-T Rec. K.12
4)
Tip or ring electrode to center electrode
5)
Total current through center electrode, half value through
tip respectively ring electrode.
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
The arrester failsafe mechanism contains a solder pellet with a melting
temperature between 193 and 203 °C.
Dimensional drawing
Not to scale
Dimensions in mm
Non controlled document
Cautions and warnings
The short-circuit spring does not trigger until 180 °C is reached depending on the material. Care
must be taken to limit the thermal radiation onto adjacent parts to safe values.
Depending on the incorporation position, the surge arrester may have to be additionally secured
by mechanical means.
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
KB AB E / KB AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 4
Issue 07 / 2007-10-18
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain
statements about the suitability of our products for
certain areas of application.
These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out
that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that
in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified.
In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g. installation
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3.
The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements,
some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”).
Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently,
the products described in this
publication may change from time to time.
The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also
reserve the right to discontinue production and delivery of products.
Consequently,
we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts,
all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MKK, MLSC, MotorCap,
PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID,
SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are
trademarks registered or
pending
in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
Page 4 of 4
查看更多>
参数对比
与T25-A230XF1相近的元器件有:B88069X8630。描述及对比如下:
型号 T25-A230XF1 B88069X8630
描述 SURGE ARRESTER 3-electrode arrester SURGE ARRESTER 3-electrode arrester
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。