TRUMPower
FEATURES
•
90 to 264 VAC universal input
•
IEC 320/C14, C6, or C8 inlet
•
Class I or class II insulation
•
Single and dual outputs
•
CEC efficiency level V compliance
42 Watt, 1-2 Output Desktop Power Adapters
TRA42 Series
CB
Output #1
Output #2
Voltage
(V)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
5
12
12
24
24
12
12
12
12
24
24
*
Part No.
ELECTRICAL SPECIFICATIONS
Input Voltage...........................................…......90~264 VAC
Input Frequency.....................................................47-63 Hz
Input Current.........……………...……….........1.2A (rms) Max.
Output Voltage………………..........................See model list
Voltage Regulation……………........Single Output ± 5% Max.
Dual Output: 3.3V ± 7% max, others ± 5% Max.
Output Wattage…………....………...………...........42W Max.
Output Protections............OVP, OLP, short circuit protection
Withstand Voltage.......................Class II: 3000 VAC, I/P-O/P
Class I: 4242 VDC, I/P-O/P; 2121 VDC , I/P-FG
Efficiency.........85% Min. @ fill load on single output models
75% Min. @ full load on dual output models
CEC Level V Compliance.....................Single output models
Standby power @ no load....<0.5 W on single output models
Voltage
(V)
11-14
14-17
17-21
21-27
27-33
33-40
40-48
3.3
3.3
3.3
3.3
3.3
3.3
5
5
5.2
5.2
5
5
Current
(A)
3.8-3.0
3.0-2.47
2.47-2.0
2.0-1.56
1.56-1.27
1.27-1.05
1.05-0.87
0.3-3
0.4-4
0.3-3
0.4-4
0.3-3
0.4-4
0.3-3
0.5-5
0.6-3
0.6-5
0.3-3
0.5-5
Current
(A)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.3-3.0
0.4-2.4
0.3-3.0
0.3-2.4
0.2-1.5
0.2-1.2
0.3-3.0
0.3-2.0
0.3-2.5
0.3-2.0
0.2-1.5
0.2-1.0
*
Max.
Output CEC
(W)
42
42
42
42
42
42
42
25
25
42
42
42
42
42
42
42
42
42
42
LP S
TRA42-S12-xG
TRA42-S15-xG
TRA42-S18-xG
TRA42-S24-xG
TRA42-S30-xG
TRA42-S36-xG
TRA42-S48-xG
TRA42-D 01-x
TRA42-D 01A-x
TRA42-D 03-x
ENVIRONMENTAL SPECIFICATIONS
Storage Temperature……………..………........-20°C to +85°C
Operating Temperature………...……....…..…-10°C to +50°C
Derating.....derate from 100% @40°C linearly to 75% @50°C
Operating Humidity.............20% to 90% RH non-condensing
MTBF.............................100,000 hours minimum at full load
and 25°C ambient calculated per MIL-HDBK-217
TRA42-D 03A-x
TRA42-D 07-x
TRA42-D 07A-x
TRA42-D 13-x
TRA42-D 13A-x
TRA42-D 13B-x
SAFETY & EMC SPECIFICATIONS
Safety Approvals….................….IEC/UL/EN60950-1,CE, CB
EMC....................EN55022, CISPR22, FCC Part 15 Class B,
EN61000-3-2/-3, EN61000-4-2/-3/-4/-5/-6/-8/-11,
EN55024
TRA42-D 13C-x
TRA42-D 17-x
TRA42-D 17A-x
* AC Inlet Code: x = 4 for C14 (class I), x = 6 for C6 (class II), x = 8 for C8 (class I)
* On dual output models, each output can load to it’s maximum current, however
the total power shall not exceed the maximum allowable output wattage.
* Contact us for output connector options.
MECHNICAL SPECIFICATIONS
117 ± 0.5
1200 ± 30
53.0 ± 0.5
UL 1185 BLACK
31.5 ± 0.5
53 ± 0.5
53 ± 0.5
53 ± 0.5
IEC 320/C14
IEC 320/C6
IEC 320/C8
umbler echnolo
hnologies TRUMP
UMPo
Tumbler Technologies + TRUMPower
Phone: 408-988-6616
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA