首页 > 器件类别 > 半导体 > 电源管理

Thyro-AX 2A 400-1500 HF RLP2

Power Conditioning Thyro-AX 2A 400-1500 HF RLP2

器件类别:半导体    电源管理   

厂商名称:Advanced Energy

下载文档
器件参数
参数名称
属性值
Product Attribute
Attribute Value
制造商
Manufacturer
Advanced Energy
产品种类
Product Category
Power Conditioning
文档预览
DIGITAL THYRISTOR SCR POWER CONTROLLERS
16 TO 1500 A
THYRO-AX®
Thyro-AX®
Digital thyristor SCR power controllers
With numerous new performance features, flexible and reliable handling,
and an integrated touch display, the Thyro-AX® SCR power controller
delivers the superior performance standards of Advanced Energy®’s
Thyro-Family products.
Thyro-AX® products precisely and reliably control power in
a range of industrial processes requiring heating, melting,
forming, or drying.
APPLICATIONS
Automotive (paint drying equipment)
Chemical (pipe trace heaters, pre-heating equipment)
Crystal growing (sapphire, silicon)
Furnace construction (industrial, diffusion, drying ovens)
Glass (plate glass equipment, feeders, finishing equipment)
Machine building (extruders, plastic presses)
Packaging (shrink tunnels)
Printing machines (IR drying)
WIDE PERFORMANCE SCOPE
The Thyro-AX series supports voltages from 24 to 600 V
and currents from 16 to 1500 A, and offers single, dual, and
three-phase units. With flexible connection technology, the
power controller can be connected from below and/or from
above.
ADVANCED COMMUNICATION AND CONTROL
The full graphic touch display enables intuitive operation
and offers advanced visualization and parameterization
options. It displays set points, actual values, operating
modes, and other parameters in plain text, and also indicates
operating mode with background lighting.
In addition to standard interfaces, Thyro-AX modules offer
Ethernet and USB 2.0. Parameterization via USB 2.0 is
possible without external supply.
For communication with higher control systems, bus
modules are available for protocols such as DeviceNet
TM
,
Modbus® RTU, PROFIBUS®, and CANopen®, as well as
for TCP/IP based communication, including PROFINET®,
Modbus® TCP, and EtherNet/IP®.
MAINS LOAD OPTIMIZATION
Intelligent technologies compensate for system
perturbations and reduce costs.
STANDARD
Internal mains load optimization for up to 12 power
controllers
OPTIONAL
Thyro-Power Manager
dASM bus module
HIGH EFFICIENCY
The high efficiency of entire Thyro-Family offers ongoing
energy savings.
SUMMARY SPECIFICATIONS
THYRO-AX SERIES
Operating Modes
TAKT
VAR (phase-angle firing)
QTM (half-wave frequency package control)
SWITCH (full-wave frequency)
Full frequency package control
Firing of each sinus half-wave
Quick operating mode for ohmic load without a transformer
Switch operating mode, also for transformer load
1-phase version for 1-phase load between 2-phases or for 1-phase connected to the neutral phase
Operating modes: TAKT, VAR, QTM, SWITCH
2A...
3A...
2-phase version for 3-phase load in cost-saving 3-phase circuit
Operating modes: TAKT, SWITCH
3-phase version for 3-phase load
Operating modes: TAKT, VAR, SWITCH
Thyro-AX Model Features
1A...
Rated Voltage
230 V
400 V
500 V
600 V
Network Frequency
24 to 253 V
24 to 440 V
24 to 550 V
24 to 660 V
For all types from 47 to 63 Hz max.
Frequency change: 5% per half-wave
Rated Current
...-xxx...
16 A, 30 A, 45 A, 60 A, 100 A, 130 A, 170 A, 230 A, 280 A, 350 A, 1000 A, 1400 A, 1500 A
Ohmic loads employed at a R
warm
/R
cold
-ratio up to 6; limitation of 3 x I
nom
Transformer loads
Mains Load
Internal network load optimization for the operating modes QTM and TAKT
Interface for external network load optimization available, e.g. Thyro-Power Manager
Load Types
Types
Functional Features
...F...
...H RLP2
Forced ventilation
Set point inputs
2 set point inputs, 2 digital inputs and 1 switch input
Input of analog set point, signal intervals, each of:
0(4) - 20 mA / 0(1) - 5 V / 0(2) - 10 V
Control input for switch operation mode - dual point control is possible
(U
On
= 3 to 24 V)
Digital set point is provided by the process computer or bus system
Control types
Load monitoring
Limitations
Relay output
Analog output
External supply
Operational display
System Interface
U
eff
/ U
2eff
/ I
eff
/ I
2eff
/ P
Via an adjustable response threshold
Current limitation I
eff
current peak limitation to Î = 3 x I
nom
for operation
mode VAR
Exchanger, max. contact load 250 V, 4 A, 180 W, 1500 VA
3 analog outputs each with signal levels of 0(2) - 10 V / 0(4) - 20 mA,
max. compliance voltage 10 V
85 to 265 V (47 to 63 Hz)
Via display and relay output (exchanger, indications adjustable)
Serial system interface for connection of optional bus module, e.g. for CANopen®, DeviceNet
TM
, EtherNet/
IP®, Modbus® RTU, Modbus® TCP, Profinet®, Profibus® DPV1
SUMMARY SPECIFICATIONS: THYRO-AX
Current
(A)
16
30
45
45
60
60
100
100
130
130
170
170
230
240
280
350
1000
1000
1400
1500
600
64
80
112
140
400
500
700
600
840
140
175
53
92
115
138
168
210
39
68
85
102
30
52
65
78
23
40
50
60
14
24
30
36
Power (kW)
230 V
3
7
10
400 V
6
12
18
500 V
8
15
22
600 V
Power Loss
(W)
25
40
51
Current
(A)
16
30
45
45
60
60
100
100
130
130
170
170
230
240
280
350
1000
1000
1400
1500
Power (kW)
400 V
11
21
31
41
69
90
117
159
194
242
693
866
1212
1039
1039
1455
500 V
14
26
39
600 V
Power Loss
(W)
49
80
101
THYRO-AX 1A ...H RLP2
THYRO-AX 2A ...H RLP2
27
61
66
72
116
130
159
182
180
211
280
332
352
399
1317
1401
1721
1761
47
52
62
86
104
112
135
147
176
199
239
242
303
363
121
131
144
231
260
318
368
360
422
600
664
702
79
2654
2822
3462
3542
THYRO-AX 3A ...H RLP2
16
30
45
45
60
60
100
100
130
130
170
170
230
240
280
350
1000
1000
1400
1500
1040
194
242
693
866
1212
1039
1455
242
303
159
199
239
291
363
118
147
176
90
112
135
69
86
104
41
52
62
11
21
31
14
26
39
47
73
121
151
182
197
216
346
390
475
544
540
632
840
995
1054
1194
3891
4143
5102
5223
AE World Headquarters
1625 Sharp Point Drive
Fort Collins, Colorado 80525
Phone
Fax
+1.970.221.0108
+1.970.407.5296
powercontroller@aei.com
advanced-energy.com
ENG-Thyro-AX-230-01 10.15
Specifications are subject to change without notice.
©2015 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy® and Thyro-AX® are U.S. trademarks of Advanced Energy Industries, Inc.
CANopen® is a trademark of CAN in Automation e.V. Modbus® is a trademark of Schneider Electric U.S.A., Inc. Profibus® and Profinet® are trademarks of Profibus and
Profinet International (PI). DeviceNet™ and EtherNet/IP® are trademarks of ODVA, Inc.
查看更多>
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消