SPECIFICATION SHEET
specifications
Category 6/Class E eight-position jack module shall
terminate unshielded twisted 4 pair, 22 – 26 AWG, 100
ohm cable and shall not require the use of a punchdown
tool. Jack module shall use forward motion termination to
optimize performance by maintaining cable pair geometry
and eliminating conductor untwist. The white termination
cap shall be color coded for T568A and T568B
wiring schemes.
TX6500
™
and TX6000
™
Copper Cabling Systems
M
INI
-C
OM
®
TX6
™
PLUS Jack Module12
TG
Module:
Plenum:
Riser:
CJ688TG*
TX6500
™
UTP Copper Cable
PUP6504**-U
PUR6504**-UY
technical information
Category 6/Class E
channel and
component performance:
FCC compliance:
IEC compliance:
Exceeds all TIA/EIA-568-B.2-1 Category 6 and ISO 11801
2nd Edition Class E standard requirements at swept
frequencies up to 250 MHz
Meets FCC Part 68 Subpart F; contacts plated with 50
microinches of gold for superior performance
Meets IEC 60603-7
TX6000
™
UTP Copper Cable
Plenum:
Riser:
3 feet:
5 feet:
7 feet:
10 feet:
14 feet:
20 feet:
PUP6004**-UY
PUR6004**-UY
TX6
™
PLUS Patch Cords
UTPSP3***Y
UTPSP5***Y
UTPSP7***Y
UTPSP10***Y
UTPSP14***Y
UTPSP20***Y
DP6
™
PLUS Flat
Punchdown Patch Panels
key features and benefits
100% performance tested
Utilizes enhanced
G
IGA
-TX
™
technology
Improved termination cap
Modularity
Confidence that each jack module will deliver the critical
electrical performance requirements
Optimizes performance by eliminating conductor untwist;
reduces installation expense
Conductor retention slots simplify termination
Jack modules snap in and out of
M
INI
-C
OM
®
Faceplates,
Modular Patch Panels and Surface Mount Boxes
for fast moves, adds and changes
Controls cable bend radius for long term
installed performance
Marked with quality control number for traceability
Familiar to end-users; backwards compatible
12-port
24-port, 1 RU:
48-port, 2 RU:
DP12688TGY
DP24688TGY
DP48688TGY
DP6
™
PLUS Angled
Punchdown Patch Panels
24-port, 1 RU:
48-port, 2 RU:
DPA24688TGY
DPA48688TGY
GP6
™
PLUS Category 6
Punchdown System
See website (www.panduit.com)
or catalog for complete
system information
Termination Tools
Jack module
termination tool:
Wire snipping tool:
Wire stripping tool:
TGJT
CWST
CJAST
True strain relief
Individual serialized
Industry standard
RJ45 interface
*To designate a color, add suffix IW (Off White),
EI (Electric Ivory), IG (Int'l Gray), WH (White),
BL (Black), OR (Orange), RD (Red), BU (Blue),
GR (Green), YL (Yellow), or VL (Violet).
applications
M
INI
-C
OM
®
TX6
™
PLUS
UTP Jack Module is a
component of the
TX6500
™
and
TX6000
™
Copper Cabling Systems. Interoperable and
backward compatible, these end-to-end
systems provide design flexibility to protect
network investments well into the future. With
certified performance to the TIA/EIA-568-B.2-1
Category 6 and ISO 11801 Class E standards,
these systems are ideal for today's high
performance workstation applications. Usage
of the
TX6500
™
and
TX6000
™
Copper Cabling
Systems include:
• Ethernet 10BASE-T, 100BASE-T (Fast
Ethernet), 1000BASE-T (Gigabit Ethernet),
10000BASE-T (10 Gigabit Ethernet over
limited distances as specified in the industry
10GBASE-T standards)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Digital video and broadband/baseband
analog video
• Voice over Internet Protocol (VoIP)
**For colors other than BU (Blue), substitute
with WH (White), YL (Yellow) or IG (Int'l Gray).
***For lengths 1 to 20 feet (increments of one
foot) and 25, 30, 35, 40 feet, change the length
designation in the part number to the desired
length. For standard cable colors other than Off
White, add suffix BL (Black), BU (Blue), GR
(Green), RD (Red), YL (Yellow), OR (Orange)
or VL (Violet) before Y at the end of the part
number. For example, the part number for a
blue 15-foot patch cord is UTPSP15BUY.
w w w. p a n d u i t . c o m
M
INI
-C
OM
®
TX6
™
PLUS UTP Jack Module
Te s t R e s u l t s
Mechanical Test
Normal Force
Vibration
Shock
Durability
Mating/Un-Mating
Termination Cycles
Test Method
—
IEC 512-6d
IEC 512-6c
IEC 512-9a
IEC 512-13b
IEC 352
Measurement
Load (grams)
Circuit Resistance (mOhms)
Contact Disturbance (microseconds)
Circuit Resistance (mOhms)
Mating Force (N)
Un-Mating Force (N)
Number of Cycles
Typical Test Results
>100
<40
<5
<40
<20
<20
>20
Electrical Test
Low Level Circuit Resistance
Dielectric Withstand Voltage
Insulation Resistance
Test Method
IEC 512-2a
IEC 512-4a
IEC 512-3a
Measurement
Resistance (mOhms)
1000 V, 1 minute
Resistance (mOhms)
Typical Test Results
<20
Passed
>500
Environmental Test
Temperature Life
Humidity
Thermal Shock
Climatic Sequence
Flowing Mixed Gas Corrosion
Test Method
IEC 512-9b
IEC 512-11c
IEC 512-11d
IEC 512-11a
IEC 512-11g
Measurement
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Circuit Resistance (mOhms)
Typical Test Results
<40
<40
<40
<40
<40
.71
(18.06)
.62
(15.87)
1.50
(38.15)
Dimensions are in inches (Dimensions in parentheses are metric).
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT
CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT
EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT
SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT
JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.3767.7011
PANDUIT
LATIN AMERICA
Jalisco, Mexico
cs-la@panduit.com
Phone: 52.333.666.2501
PANDUIT
AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
For a copy of
PANDUIT
product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800-777-3300 and reference COSP48
©2008
PANDUIT
Corp.
ALL RIGHTS RESERVED.
WW-COSP48
3/2008