首页 > 器件类别 >

VSYS5

Emergency Voice Evacuation

厂商名称:Gamewell-FCI ( Honeywell )

厂商官网:http://www.gamewell-fci.com

下载文档
文档预览
Emergency Voice Evacuation
VSYS Options for IF610 Analog
Addressable Control Panel
Description
The 610VE panel’s VSYS option adds
emergency voice evacuation capabilities
to the IdentiFlex 610 (IF610) analog ad-
dressable Fire Alarm Control Panel
(FACP).
The VSYS options are integrated in the
same housing as the IF610, delivering
dependable performance in an attractive
cabinet design.
VSYS systems provide prerecorded digi-
tal alert messages, all-call, and indi-
vidual control-by-circuit (microphone).
The emergency voice evacuation capa-
bility of the IF610 is used to provide pre-
recorded natural-voice messages (VEX)
and emergency paging to facilitate or-
derly evacuation of protected areas.
Voice evacuation systems are frequently
required by the Authority Having Jurisdic-
tion (AHJ) for areas of assembly such as
auditoriums, gymnasiums, places of worship, and large meeting rooms. IF610/VSYS
systems are suited to meet these needs and the requirements of NFPA 101 for New
and Existing Assembly Occupancies.
g2002ph1.jpg
Features
Integrated voice in IF610 cabinet.
• 25, 50, 100, or 200-watt sys-
tems.
• 25-volt or 70-volt operation.
• Fully supervised amplifier.
• Multiple EVAC tones.
• Four-minute message capacity.
• Digital prerecorded voice evacua-
tion messages.
• Paging microphone with override.
• All-call function.
• Single or multiple speaker
circuits (up to eight Class A or
eight Class B maximum).
Listings
Listings and approvals below
apply to the basic VSYS/VEX
components. In some cases,
certain modules may not be
listed by certain approval agen-
cies, or listing may be in pro-
cess. Consult factory for latest
listing status.
• UL Listed: file S521.
• CSFM approved: files 7165-
1288:154, 7170-1288:153.
• MEA approved: file 149-99-E Vol.
II.
Systems are available in 25, 50, 100, and 200-watt configurations. The IF610 with
VSYS option can be configured for one to eight speaker circuits at up to 25 watts per
circuit. Each amplifier offers an independent power supply and battery charger with
a digital message repeater (VEX).
System Operation
The VSYS option is a flexible voice solution that can be sized to meet the job require-
ments by selecting the style and number of speaker circuits and the size of the am-
plifier. The system is also available with prerecorded digital message, and includes
emergency paging capability.
The VSYS includes a three-minute message restart, which occurs automatically after
a three-minute depression of the microphone key when the digital messaging op-
tion is used.
The VSYS Emergency Voice Evacuation System may also be ordered with multiple
speaker-circuit configurations. Circuit-splitter modules allow the amplifier power to
be divided among multiple zones for efficient use and controlled zone signaling.
Splitter modules are equipped with circuit-select switches that allow for manual
selection of voice evacuation zones for emergency paging. An LED is provided for
annunciation of each zone’s status.
Enclosures can house up to 200 watts of amplification, a paging microphone, digital
voice messaging, and one or two circuit-splitter modules for up to eight Class B (Style
Y) or up to four Class A (Style Z) circuits. Circuits are rated at 25 watts each. VSYS
provides an integral battery charger for its dedicated batteries. Supervised remote
microphones are supported by the system. Speaker circuits are controlled by indi-
vidual toggle switches. A circuit identification label is provided for field-customized
circuit labeling.
VSYS for IF610
CS-2002 09/01/06
Page 1 of 2
Ordering Information
VSYS1
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX25
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX25-4B
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX50
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX50-4B
voice system
mounted in the cabinet.
IF610-252VE includes main CPU board, display board, keypad,
two-
loop
card, and 6 A power supply; plus
VEX50-4B
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX100-4B
voice system
mounted in the cabinet.
IF610-252VE includes main CPU board, display board, keypad,
two-
loop
card, and 6 A power supply; plus
VEX100-4B
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX200-8B
voice system
mounted in the cabinet.
IF610-252VE includes main CPU board, display board, keypad,
two-
loop
card, and 6 A power supply; plus
VEX200-8B
voice system
mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX25-2A
Class A voice
system mounted in the cabinet.
IF610-126VE includes main CPU board, display board, keypad,
single-loop
card, and 6 A power supply; plus
VEX50-4A
Class A voice
system mounted in the cabinet.
IF610-252VE includes main CPU board, display board, keypad,
two-
loop
card, and 6 A power supply; plus
VEX100-4A
Class A voice
system mounted in the cabinet.
IF610-252VE includes main CPU board, display board, keypad,
two-
loop
card, and 6 A power supply; plus
VEX200-8A
Class A voice
system mounted in the cabinet.
IF610-504VE includes main CPU board, display board, keypad,
four-
loop
card, and 6 A power supply; plus
VEX100-4B
voice system
mounted in the cabinet.
IF610-504VE includes main CPU board, display board, keypad,
four-
loop
card, and 6 A power supply; plus
VEX200-8B
voice system mounted in
the cabinet.
Specifications
Voice evacuation system
Input power
25 watt, 50 watt:
120 VAC, 0.80 A.
100 watt:
120 VAC, 0.60 A.
200 watt:
120 VAC, 1.20 A.
Current
25 watt:
0.18 A standby, 1.00 A
alarm.
50 watt:
0.13 A standby, 1.00 A
alarm.
100 watt:
0.18 A standby, 2.50 A
alarm.
200 watt:
0.36 A standby, 5.00 A
alarm.
Battery charging capabilities
25 watt, 50 watt:
up to 18 AH.
100 watt:
up to 24 AH.
200 watt:
up to 48 AH.
VSYS2
VSYS3
VSYS4
VSYS5
VSYS6
VSYS7
VSYS8
VSYS9
VSYS10
VSYS11
VSYS12
Separate sources of 120 VAC input
power and 24 VDC battery backup
power are used for the Fire Alarm Con-
trol Unit and the Voice Evacuation sys-
tem. AC power source requirements
are determined by adding the amper-
age requirements of the two systems
together. Independent battery backup
calculations must be completed for the
Fire Alarm Control Unit and the Voice
Evacuation system.
Dimensions
Cabinet:
30.0" H x 22.0" W x 5.5" D
(cm: 76.2 H x 55.88 W x 13.97 D)
for all VSYS options.
Battery storage:
6.5" H x 22.0" W x
4.5" D (cm: 16.51 H x 55.88 W x
11.43 D).
Relative humidity
93% noncondensing.
Temperature rating
VSYS14
VSYS15
VSYS16
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472
Phone: 203-484-7161
Fax: 203-484-7118
www.gamewell-fci.com
A Honeywell Company
© 2006 Gamewell-FCI
32°F – 120°F (0°C – 49°C).
Specifications and wiring information are provided for information only and are
believed to be accurate. Gamewell-FCI assumes no responsibility for their use.
Data and design are subject to change without notice. Installation and wiring
instructions shipped with the product shall always be used for actual installation.
For more information, contact Gamewell-FCI.
Page 2 of 2
VSYS for IF610
CS-2002 09/01/06
查看更多>
热门器件
热门资源推荐
器件捷径:
00 01 02 03 04 05 06 07 08 09 0A 0C 0F 0J 0L 0M 0R 0S 0T 0Z 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 1H 1K 1M 1N 1P 1S 1T 1V 1X 1Z 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 2G 2K 2M 2N 2P 2Q 2R 2S 2T 2W 2Z 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 3G 3H 3J 3K 3L 3M 3N 3P 3R 3S 3T 3V 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4M 4N 4P 4S 4T 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5E 5G 5H 5K 5M 5N 5P 5S 5T 5V 60 61 62 63 64 65 66 67 68 69 6A 6C 6E 6F 6M 6N 6P 6R 6S 6T 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7M 7N 7P 7Q 7V 7W 7X 80 81 82 83 84 85 86 87 88 89 8A 8D 8E 8L 8N 8P 8S 8T 8W 8Y 8Z 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9F 9G 9H 9L 9S 9T 9W