W005F....W10F
1.5 Amp. Glass Passivated Bridge Rectifier
Voltage
50 V to 1000 V
FEATURES
High case dielectric strength
High forward surge current capability
Ideal for printed circuit boards
Solder dip 260ºC, 40s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Typical I
R
less than 0.1µA
MECHANICAL DATA
Case
:
ROUND
Epoxy meets UL 94V-0 flammability rating.
Polarity
:
As marked on body.
Terminals
:
Silver plated leads, solderable per J-STD-002
and JESD22-B102.
Consumer grade.
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for SMPS,
lighting ballaster, adapter, battery charger, home appliances, office
equipment, and telecommunication applications..
ROUND
Current
1.5 A
+
~
~
-
Maximun Ratings and Electrical Characteristics at 25°C
W005F W01F
Marking code
W005F
W01F
W02F
W02F
W04F
W04F
W06F W08F
W06F
W08F
W10F
W10F
V
RRM
V
RMS
V
DC
I
F (AV)
I
FRM
I
FSM
I
2
t
T
j
T
stg
Peak recurrent reverse voltage (V)
Maximum RMS voltage (V)
Maximum DC blocking voltage (V)
Forward current at Tamb = 25°C
Recurrent peak forward current
10 ms. peak forward surge current
(Jedec Method)
50
35
50
R Load
C Load
100
70
100
200
140
200
400
280
400
1.5 A
1.2 A
15 A
50 A
12 A
2
sec
600
420
600
800
560
800
1000
700
1000
I
2
t value for fusing (t = 10 ms)
Operating temperature range
Storage temperature range
55 to + 125 °C
55 to + 150 °C
Electrical Characteristics at Tamb = 25 °C
V
F
I
R
Max. forward voltage drop per
element at I
F
= 1.0 A
Max. reverse current per element at
V
RRM
1.0 V
10 µA
www.fagorelectronica.com
Document Name: wf
Version: Mar-12
Page Number: 1/4
W005F....W10F
1.5 Amp. Glass Passivated Bridge Rectifier
Ordering information
PREFERRED P/N
W06F
W06FA
W06FB
PACKAGE CODE
BU
BU
BU
DELIVERY MODE
BULK
BULK
BULK
BASE QUANTITY
1,000
3,000
3,000
UNIT WEIGHT (g)
1.12
1.09
1.09
Package Outline Dimensions: (mm) ROUND
Long leads
5
±0.5
9.5
±0.5
Short leads
8.5
±0.5
Suffix
"A"
L
±0.5
4
3
5
±0.5
"B"
4.1
±0.5
30
±1
4.1
±0.5
ø0.8
±0.05
C Serie
W Serie
L
±0.5
ø0.8
±0.05
Test sorting code
Marking code
Marking code
Year code
Week code
Year code
Week code
www.fagorelectronica.com
Document Name: wf
Version: Mar-12
Page Number: 2/4
W005F....W10F
1.5 Amp. Glass Passivated Bridge Rectifier
Ratings and Characteristics
(Ta 25 ºC unless otherwise noted)
1.6
Bridge Output Full Wave Rectified
Current Average (A)
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
20
0.375"
(9.5 mm)
Bridge Output Full Wave Rectified
Current Average (A)
50 to 60 Hz
Resistive or
Inductive Load
Capacitive Load
< 500 µF
500 - 5000 µF
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
20
0.375"
(9.5 mm)
Capacitive
Load
50 to 60 Hz
Resistive or
Inductive Load
0 - 10 µF
10 - 100 µF
> 100 µF
P.C.B.
P.C.B.
Copper Pads
0.22 x 0.22" (5.5 x 5.5 mm)
40
60
80
100
120
140
Copper Pads
0.22 x 0.22" (5.5 x 5.5 mm)
40
60
80
100
120
140
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure 1. Derating Curves Output Rectified Current for
W005F...W04F
Figure 2. Derating Curves Output Rectified Current for
W06F...W10F
75
10
60
Instantaneous Reverse Current (µA)
Peak Forward Surge Current (A)
T
J
= 25 °C
10 ms Single Sine-Wave
1
45
T
J
= 100 °C
30
0.1
15
1.0 Cycle
0
1
10
100
T
J
= 25 °C
0.01
0
20
40
60
80
100
Number of Cycles at 50 Hz
Percent of Rated Peak Reverse Voltage (%)
Figure 3. Maximum Non-Repetitive Peak Forward Surge
Current Per Diode
Instantaneous Forward Surge Current (A)
100
T
J
= 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
10
Figure 4. Typical Reverse Characteristics Per Diode
100
Junction Capacitance (pF)
T
J
= 25 °C
f = 1.0 MHz
V
sig
= 50 mVp-p
1
10
0.1
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1
0.1
1
10
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Figure 5. Typical Forward Characteristics Per Diode
Figure 6. Typical Junction Capacitance Per Diode
www.fagorelectronica.com
Document Name: wf
Version: Mar-12
Page Number: 3/4
W005F....W10F
1.5 Amp. Glass Passivated Bridge Rectifier
Disclaimer
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.
www.fagorelectronica.com
Document Name: wf
Version: Mar-12
Page Number: 4/4