Range of product
Series name
Product or component type
Product specific application
Device short name
Sensor design
Body type
Head type
Material
Fixing mode
Movement of operating head
Type of operator
Switch actuation
Type of approach
Electrical connection
Cable entry
Number of poles
Contacts type and composition
Contact operation
Number of steps
Positive opening
Minimum force for tripping
OsiSense XC
Special format
Limit switch
Materials handling
XC1AC
-
Fixed
Plunger head
Metal
By the body
Linear
Spring return plunger metal
On end
Vertical approach 1 direction
Screw-clamp terminals, 1 x 0.5...1 x 2.5 mm²
3 entries tapped for Pg 13.5 cable gland, cable outer diameter: 0.35...0.47 in (9...12 mm)
2
2 NC
Slow-break, simultaneous
1
Without
33 N
Complementary
Contacts insulation form
Maximum actuation speed
[Ithe] conventional enclosed thermal
current
[Ui] rated insulation voltage
Zb
3.28 ft/s (1 m/s) from left
1.64 ft/s (0.5 m/s) from right
10 A
600 V AC CSA C22.2 No 14
600 V DC CSA C22.2 No 14
500 V AC IEC 60947-5-1
500 V AC NF C 20-040
1
Jul 23, 2019
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
600 V DC IEC 60947-5-1
600 V DC NF C 20-040
Resistance across terminals
Short-circuit protection
Electrical durability
<= 8 mOhm
10 A cartridge fuse gG
1000000 cycles AC-15, 110 V 900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
1000000 cycles AC-15, 230 V 1900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
1000000 cycles AC-15, 48 V 450 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
1000000 cycles DC-13, 110 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
1000000 cycles DC-13, 230 V 95 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
1000000 cycles DC-13, 48 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
3000000 cycles AC-15, 110 V 350 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
3000000 cycles AC-15, 230 V 430 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
3000000 cycles AC-15, 48 V 170 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C 50/60 Hz, inductive load type
3000000 cycles DC-13, 110 V 40 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
3000000 cycles DC-13, 230 V 33 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
3000000 cycles DC-13, 48 V 35 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
appendix C inductive load type
10000000 cycles
3.03 in (77 mm)
6.18 in (157 mm)
1.73 in (44 mm)
1.92 lb(US) (0.87 kg)
(13-14)NO
(23-24)NO
Mechanical durability
Width
Height
Depth
Product weight
Terminals description ISO n°1
Environment
Shock resistance
Vibration resistance
IP degree of protection
Electrical shock protection class
Ambient air temperature for operation
Ambient air temperature for storage
Protective treatment
Operating position
Product certifications
Standards
95 gn 11 ms IEC 60068-2-27
9 gn 10...500 Hz IEC 60068-2-6
IP65 IEC 60529
IP65 NF C 20-010
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
-13...158 °F (-25...70 °C)
-40...158 °F (-40...70 °C)
TC
Any position
CSA
IEC 60337-1
VDE 0660-200
CSA C22.2 No 14
EN 60947-5-1
IEC 60947-5-1
Ordering and shipping details
Category
Discount Schedule
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
18407 - WORLD SERVICE PARTS(SENSORS)
T
1
1.26
N
2
Offer Sustainability
RoHS (date code: YYWW)
REACh
Product end of life instructions
California proposition 65
- - - - - - - Substance 1
- - - - - - - Substance 2
- - - - - - - More information
Will not be compliant
Will not be compliant
Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Need no specific recycling operations
WARNING: This product can expose you to chemicals including:
Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and
Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other