BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
TYPES YA, YA-TC
CRIMPS
DIE AND COLOR
CODE INFORMATION
NO INSPECTION
WINDOW
BEVELED
ENTRY
C-16
UNINSULATED COPPER
COMPRESSION TERMINAL
UL Listed 90° C,
600 Volts to 35 KV
◆
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
B
90°
B
T
L
T
45°
L
T
B
L
Fig. 1
Conductor
Catalog Number
YA8C-TC10
YA8C-TC10-45
YA8C-TC10-90
YA8C-TC14
YA8C-TC14-45
YA8C-TC14-90
YA8C-TC38
YA8C-TC38-45
YA8C-TC38-90
YA6C-TC10
YA6C-TC10-45
YA6C-TC10-90
YA6C-N
YA6C-N-45
YA6C-N-90
YA6C
YA6C-45
YA6C-90
YA5C
YA5C-45
YA5C-90
YA5C-N
YA5C-N-45
YA5C-N-90
YA4C-TC10
YA4C-TC10-45
YA4C-TC10-90
YA4C
YA4C-45
Fig #
AWG
1
2
#8 AWG
3
1
#8 WELD
2
3
37/24
1
2
#6 SOL
3
1
2
3
1
2
#6 AWG
3
1
2
3
1
2
3
#5 AWG
1
2
3
1
2
3
#4 AWG
1
2
***
MM
2
Stud
Hole
Size
# 10
†
10
Tongue
Width
.38
Figure
Dimensions
(B)
(T)
(L)
1.57
.81
.08
1.46
.68
1.69
.81
.08
1.57
.86
1.88
.81
.06
1.71
1.04
1.89
1.12
.09
1.72
.75
2.64
1.12
.12
2.53
1.52
1.81
1.12
.09
1.24
.81
1.98
1.12
.07
1.75
.81
2.67
1.12
.12
2.55
1.52
1.94
1.12
.09
1.94
1.75
1.87
1.12
.09
1.52
Dieless
(# of crimps)
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
1/4
.41
MRC840 (2)
W8CVT (2) X8CRT (2)
Y8MBR-1 (1)
W8CRT (2) W8CVT (2)
Y2MR (2)
X8CRT (2) W8CRT (2)
Y1MR (2)
U8CRT (2)
Red
49
1
3/8
.58
# 10
.41
-
1/2
.83
1/4
.41
MRC840 (2)
MY29-3 (2) W5CVT (2) W5CVT (2)
MY29-11 (2) W5CRT (2) W5CRT (2)
Y2MR (2)
X5CRT (2) X5CRT (2)
Y644M (1) X8CART (2) X8CART (2)
Y1MR (1)
Y1MR (1)
MRC840 (2)
MY29-3 (2)
MY29-11 (2)
Y2MR (2)
Y644M (1)
MRC840 (2)
MY29-3 (2)
MY29-11 (2)
Y2MR (4)
Y644M (1)
U5CRT (2)
U8CABT (2)
Blue
7
1-3/16
1/4
-
1/2
.44
.83
W5CVT (2) W5CVT (2)
W5CRT (2) W5CRT (2)
X5CRT (2) X5CRT (2)
U5CRT (2)
Blue
7
1-3/16
# 10
1/4
.49
.50
W4CVT (2) W4CVT (2)
W4CRT (2) W4CRT (2)
X4CRT (2) X4CRT (2)
U4CRT (2)
U6CABT (2)
Gray
8
1-3/16
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
† The MM
2
conductor size listed is for Class 2 and Class 5
conductor.
▲
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for "-
FX" connectors. For nest/indentor system contact factory.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(Continued)
Conductor
Catalog Number
YA4C-90
YA4C-TC38
YA4C-TC38-45
YA4C-TC38-90
YA4C-N
YA4C-N-45
YA4C-N-90
YA3C-TC14
YA3C-TC14-45
YA3C-TC14-90
YA3C
YA3C-45
YA3C-90
YA3C-TC38
YA3C-TC38-45
YA3C-TC38-90
YA3CN
YA3CN-45
YA3CN-90
YA2C-TC10
YA2C-TC10-45
YA2C-TC10-90
YA2C-TC14
YA2C-TC14-45
YA2C-TC14-90
YA2C
YA2C-45
YA2C-90
YA2C-N
YA2C-N-45
YA2C-N-90
YA1C-TC10
YA1C-TC10-45
YA1C-TC10-90
YA1C
YA1C-45
YA1C-90
YA1C-N
YA1C-N-45
YA1C-N-90
YA25TC10
YA25TC10-45
YA25TC10-90
YA25
YA25-45
YA25-90
YA25TC38
YA25TC38-45
YA25TC38-90
Fig #
AWG
3
1
2
3
#4 AWG
1
2
3
1
2
3
1
2
#3 AWG
3
1 #2 SOLID
2
3
1
2
3
1
2
3
1
2
3
#2 AWG
1
2
3
1
2
3
1
2
3
1
2
#1 AWG
3
1
2
3
1
2
3
1
2
1/0 AWG
3
1
2
3
***
MM
2
Stud
Hole
Size
1/4
3/8
-
1/2
.83
Tongue
Width
.56
.58
Figure
Dimensions
(B)
(T)
(L)
1.12’ .09
.84
2.25
1.12
.08
2.02
1.08
2.69
1.12
.12
2.56
1.54
2.23
1.25
.09
1.99
.92
2.30
1.25
.09
2.05
.98
2.42
1.25
.08
2.16
1.10
2.86
1.25
.12
2.68
1.56
2.10
1.25
.11
1.90
.82
2.23
1.25
.11
2.02
.95
2.29
1.25
.11
2.09
1.01
2.88
1.25
.12
2.70
1.58
2.27
1.38
.10
2.00
.84
2.45
1.38
.10
2.19
1.03
3.06
1.38
.12
2.82
1.60
2.30
1.38
.12
2.06
.88
2.48
1.38
.12”
2.25
1.07
2.61
1.38
.12
2.37
1.19
Dieless
(# of crimps)
B
90°
T
45°
L
L
T
L
B
B
T
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
C-17
MRC840 (2)
MY29-3 (2)
W4CVT (2) W4CVT (2)
MY29-11 (2)
W4CRT (2) W4CRT (2)
Y2MR (4)
X4CRT (2) X4CRT (2)
Y644M (1)
Y1MR (4)
U4CRT (2)
U6CABT (2)
Gray
8
1-3/16
1/4
.55
5/16
25
3/8
.55
MY29-3 (2)
MY29-11 (2) W3CRT (2) W3CRT (2)
Y644M (1)
U3CRT (2)
White
9
1-1/2
.61
1/2
.81
# 10
.61
1/4
35
5/16
.60
.61
Y1MR (4)
MRC840 (2)
W2CVT (2) W2CVT (2)
MY29-3 (2)
W2CRT (2) W2CRT (2)
MY29-11 (2)
X2CRT (2) X2CRT (2)
Y2MR (4)
Y644M (1)
U2CRT (2)
Brown
10 1-5/16
1/2
.83
# 10
.68
50
5/16
.68
Y1MR (4)
MRC840 (2) W1CVT (2) W1CVT (2)
MY29-3 (2) W1CRT-1 (2) W1CRT-1 (2)
MY29-11 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)
U1CRT-1 (2)
U4CABT (2)
Green
11 1-7/16
1/2
.83
# 10
.75
-
5/16
.75
MRC840 (4)
W25VT (4) W25VT (4)
MY29-3 (2)
W25RT (4) W25RT (4)
MY29-11 (2)
X25RT (4) X25RT (4)
Y644M (1)
U25RT (2)
U2CABT (2)
Pink
12 1-7/16
3/8
.75
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(Continued)
Conductor
Catalog Number
YA25N
YA25N-45
YA25N-90
YA26
YA26-45
YA26-90
YA26N
YA26N-45
YA26N-90
YA27
YA27-45
YA27-90
YA28TC38
YA28TC38-45
YA28TC38-90
YA28
YA28-45
YA28-90
YA29
YA29-45
YA29-90
YA30
YA30-45
YA30-90
YA31
YA31-45
YA31-90
YA32N
YA32N-45
YA32N-90
YA32
YA32-45
YA32-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
1/0
AWG
***
MM
2
-
Stud
Hole
Size
1/2
Tongue
Width
.81
Figure
Dimensions
(B)
(T)
(L)
3.05
1.38
.11
2.79
1.62
2.77
2.49
1.22
3.21
2.93
1.65
3.06
2.78
1.49
2.98
2.68
1.29
3.23
2.93
1.54
3.26
2.99
1.58
3.69
3.31
1.61
3.73
3.36
1.65
4.09
3.71
1.88
4.15
3.77
1.95
Dieless
(# of crimps)
B
90°
T
45°
L
L
T
L
B
B
T
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
U25RT (2)
U2CABT (2)
Fig. 3
Wire
Color Die Strip
Code Index Length
Pink
12
1-7/16
C-18
MRC840 (4)
W25VT(4) W25VT (4)
MY29-3 (2)
W25RT (4) W25RT (4)
MY29-11 (2)
X25RT (4) X25RT (4)
Y644M (1)
MRC840 (4)
W26VT (4) W26VT (4)
MY29-3 (2)
W26RT (4) W26RT (4)
MY29-11 (2)
X26RT (4) X26RT (4)
Y644M (1)
MRC840 (4)
W27VT (4) W27VT (4)
MY29-3 (2)
W27RT (4) W27RT (4)
MY29-11 (2)
X27RT (6) X27RT (6)
Y644M (1)
MRC840 (4)
W28VT (4) W28VT (4)
MY29-3 (2)
W28RT (4) W28RT (4)
MY29-11 (2)
X28RT (6) X28RT (6)
Y644M (1)
MY29-3 (2)
W29VT (4)
MY29-11 (2)
X29RT (8)
Y644M (1)
Y644M (1)
W30VT (4)
W29VT (4)
W29RT (4)
X29RT (8)
W30VT (4)
W30RT (4)
W31VT (4)
W31RT (4)
3/8
2/0
AWG
70
1/2
.83
1.50
.12
U26RT (2)
Black
13
1-9/16
.83
1.50
.12
3/0 AWG
-
1/2
.91
1.50
.13
U27RT (2)
Orange
14
1-9/16
3/8
4/0 AWG
-
1/2
1.02
1.62
.14
U28RT (2)
Purple
15
1-1/16
250 kcmil
-
1/2
1.11
1.62
.16
U29RT (2)
U30RT (4)
U28ART (4)
U31RT (4)
U29ART (4)
Yellow
16
1-1/16
300 kcmil
150
1/2
1.20
2.00
.16
White
17 or
2-1/16
298
18 or
2-1/16
324
350 kcmil
185
1/2
1.29
2.00
.18
Y644M (1)
W31VT (4)
Red
1/2
400 kcmil
-
5/8
1.38
2.12
.19
Y644M (1)
W32VT (4)
W32VT (4)
W32RT (4)
U32RT (4)
U30ART (4)
Blue
19 or
2-3/16
470
1.38
2.12
.19
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(Continued)
Conductor
Catalog Number
YA33
YA33-45
YA33-90
YA33-N
YA33-N-45
YA33-N-90
YA34N
YA34N-45
YA34N-90
YA34
YA34-45
YA34-90
YA35
YA35-45
YA35-90
YA35-N
YA35-N-45
YA35-N-90
YA36N
YA36N-45
YA36N-90
YA36
YA36-45
YA36-90
YA37
YA37-45
YA37-90
YA37-N
YA37-N-45
YA37-N-90
YA38
YA38-45
YA38-90
YA38-N
YA38-N-45
YA38-N-90
YA39N
YA39N-45
YA39N-90
YA39
YA39-45
YA39-90
YA40
YA40-45
YA40-90
YA40-N
YA40-N-45
YA40-N-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud
Hole
Size
5/8
450 kcmil
-
1/2
1.48
Tongue
Width
1.48
Figure
Dimensions
(B)
(T)
(L)
4.24
2.13
.21
3.87
2.00
4.17
2.13
.21
3.81
1.94
4.32
2.25
.23
3.96
1.97
4.39
2.25
.23
4.02
2.03
4.79
2.63
.25
4.37
2.08
4.73
2.63
.25
4.30
2.01
4.83
2.69
.27
4.41
2.05
4.90
2.69
.27
4.47
2.11
5.05
2.81
.27
4.59
2.14
4.98
2.81
.27
4.53
2.08
5.07
2.81
.27
4.60
2.15
5.01
2.81
.27
4.53
2.08
5.11
2.88
.27
4.62
2.11
5.17
2.88
.27
4.68
2.17
5.25
2.94
.30
4.80
2.21
5.19
2.94
.30
4.74
2.15
Dieless
(# of crimps)
B
90°
T
45°
L
L
T
L
B
B
T
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
-
W33VT (4)
W33VT (4)
W33RT (4)
U33RT (4)
Fig. 3
Wire
Color Die Strip
Code Index Length
C-19
Gray
326 or
2-5/16
538
1/2
500 kcmil
240
5/8
1.52
W34VT (4)
W34VT (4)
W34RT (4)
U34RT (4)
U31ART (4)
Brown
20 or
2-5/16
299
1.52
5/8
550 kcmil
-
1/2
1.65
-
-
U35RT (4)
Yellow
21
2-11/16
1.65
1/2
600 kcmil
300
5/8
1.69
-
Y644M (1)
-
U36RT (4)
U32ART (4)
Green
22 or
2-3/4
472
1.69
5/8
650 kcmil
-
1/2
1.80
-
-
U37RT (4)
Orange
23
2-7/8
1.80
5/8
700 kcmil
-
1/2
1.84
-
-
-
U38RT (4)
Pink
400
2-7/8
1.84
1/2
750 kcmil
-
5/8
1.89
-
-
1.89
U39RT (4)
P39RT (4)
**
Black
24
2-15/16
5/8
800 kcmil
400
1/2
1.98
-
-
P40RT (4)
**
Orange
25
3
1.98
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and
die listings. Use ONLY color coded die recommendations
for "-FX" connectors. For nest/indentor system contact
factory.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(Continued)
Conductor
Catalog Number
YA41
YA41-45
YA41-90
YA41-N
YA41-N-45
YA41-N-90
YA44
YA44-45
YA44-90
YA44-N
YA44-N-45
YA44-N-90
YA45
YA45-45
YA45-90
YA45-N
YA45-N-45
YA45-N-90
YA46
YA46-45
YA46-90
YA46-N
YA46-N-45
YA46-N-90
YA47
YA47-45
YA47-90
YA47-N
YA47-N-45
YA47-N-90
YA48
YA48-45
YA48-90
YA48-N
YA48-N-45
YA48-N-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud
Hole
Size
5/8
850 kcmil
-
1/2
2.01
Tongue
Width
2.01
Figure
Dimensions
(B)
(T)
(L)
5.26
2.94
.31
4.82
2.23
5.20
2.91
.31
4.76
2.17
5.45
3.00
.33
5.01
2.32
5.38
3.00
.33
4.95
2.26
5.93
3.19
.38
5.52
2.62
5.68
3.19
.38
5.27
2.37
6.04
3.19
.40
5.64
2.71
5.79
3.19
.40
5.39
2.46
6.38
3.44
.42
5.94
2.79
6.13
3.44
.42
5.69
2.54
6.47
3.44
.46
6.09
2.89
6.22
3.44
.46
5.84
2.64
Dieless
(# of crimps)
B
90°
T
45°
L
L
T
L
B
B
T
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
C-20
-
-
-
Gold
26
3
Y644M (1)
P44RT (4)
**
5/8
1000 kcmil
500
1/2
2.17
-
-
White
27 3-1/16
2.19
3/4
1250 kcmil
-
1/2
2.46
-
-
P45RT (6)
**
Yellow
29
3-1/4
2.46
3/4
1500 kcmil
-
1/2
2.69
-
-
P46RT (6)
**
Green
31 3-5/16
2.69
3/4
1750 kcmil
-
1/2
2.90
-
-
-
Gray
33
3-1/2
2.90
3/4
2000 kcmil
-
1/2
3.10
-
-
-
Brown
34
3-1/2
3.10
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.