首页 > 器件类别 > 连接器

YAV4CL-TC12-FX-45

Wire Terminal

器件类别:连接器   

厂商名称:Amphenol(安费诺)

厂商官网:http://www.amphenol.com/

下载文档
器件参数
参数名称
属性值
是否无铅
含铅
是否Rohs认证
不符合
厂商名称
Amphenol(安费诺)
Reach Compliance Code
compliant
ECCN代码
EAR99
制造商序列号
YAV-L-FX
终端性别
FEMALE
端子和端子排类型
WIRE TERMINAL
线规
4 AWG
文档预览
BURNDY
Compression
ONE HOLE HYLUG™
FLEX CONDUCTOR
STANDARD BARREL
TYPES YA-L, YA-L-FX, YAV,
YAV-L-FX
ELECTRO-TIN
PLATED
DIE AND COLOR
CODE INFORMATION
BEVELED
ENTRY
INSPECTION
WINDOW
CRIMP
CABLE
ACCOMMODATION
C-22
COPPER COMPRESSION
TERMINAL
UL LISTED 90° C,
600 VOLT TO 35 KV
x
B
B
T
L
T
45°
L
T
B
90°
L
Fig. 1
Fig. 2
Fig. 3
Conductor
Catalog Number
Fig #
AWG
YA8CL-BOX
1
YA8CL-45
2
YA8CL-90
3
YA8C-L1-BOX
1
YA8C-L1-45
2
YA8C-L1-90
3
37/24
YA8C-L2-BOX
1
YA8C-L2-45
2
#8 Weld
YA8C-L2-90
3
YA8C-L3-BOX
1
#8 AWG
YA8C-L3-45
2
YA8C-L3-90
3
YA8C-L4-BOX
1
YA8C-L4-45
2
YA8C-L4-90
3
YAV6CL-TC10-FX
1
YAV6CL-TC10-FX-45
2
YAV6CL-TC10-FX-90
3
YAV6CL-TC12-FX
1
YAV6CL-TC12-FX-45
2
YAV6CL-TC12-FX-90
3
61/24
YAV6CL-TC14-FX
1
YAV6CL-TC14-FX-45
2
#6 WELD
YAV6CL-TC14-FX-90
3
YAV6CL-TC38-FX
1
#6 AWG
YAV6CL-TC38-FX-45
2
YAV6CL-TC38-FX-90
3
YAV6CL-TC516-FX
1
YAV6CL-TC516-FX-45
2
YAV6CL-TC516-FX-90
3
***
MM
2
Stud
Hole
Size
8-10
Tongue
Width
.41
Figure
Dimensions
(B)
(T)
(L)
1.16
.44
.08
1.16
.71
1.26
.44
.08
1.24
.80
1.38
.44
.08
1.34
.92
1.51
.44
.08
1.45
1.04
1.76
.44
.08
1.67
1.28
1.30
.50
.08
1.26
.76
1.86
.50
.12
1.92
1.34
1.43
.50
.08
1.39
.88
1.61
.50
.06
1.54
1.06
1.49
.50
0.07
1.44
.94
Dieless
(# of crimps)
Mechanical
MD6, OUR840
MD7-34R
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
1/4
**
5/16
10
3/8
.44
.52
Y1MR (1)
W8CVT (1) W8CVT (1)
Y8MRB-1
W8CRT (1) W8CRT (1)
Y2MR (1)
X8CRT (1) X8CRT (1)
MY29-11 (1)
UCRT (1)
Red
49
7/16
.58
1/2
.71
8-10
.48
1/2
**
1/4
16
3/8
.75
.48
Y1MR (1)
W5CVT (1) W5CVT (1)
Y2MR (1)
W5CRT (1) W5CRT (1)
MY29-11 (1)
X5CRT (1) X5CRT (1)
Y644M (1)
U5CRT (1)
Blue
7
1/2
.60
5/16
.60
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** The MM
2
conductor size listed is for both Class 2 and Class 5 conductors.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
FLEX CONDUCTOR
STANDARD BARREL
(CONTINUED)
Conductor
Catalog Number
Fig #
YAV6CL-TC34-FX
1
YAV6CL-TC34-FX-45
2
YAV6CL-TC34-FX-90
3
YAV4CL-TC10-FX
1
YAV4CL-TC10-FX-45
2
YAV4CL-TC10-FX-90
3
YAV4CL-TC12-FX
1
YAV4CL-TC12-FX-45
2
YAV4CL-TC12-FX-90
3
YAV4CL-TC14-FX
1
YAV4CL-TC14-FX-45
2
YAV4CL-TC14-FX-90
3
YAV4CL-TC38-FX
1
YAV4CL-TC38-FX-45
2
YAV4CL-TC38-FX-90
3
YAV4CL-TC516-FX
1
YAV4CL-TC516-FX-45
2
YAV4CL-TC516-FX-90
3
YAV2CL-TC10-FX
1
YAV2CL-TC10-FX-45
1
YAV2CL-TC10-FX-90
1
YAV2CL-TC12-FX
1
YAV2CL-TC12-FX-45
1
YAV2CL-TC12-FX-90
1
YAV2CL-TC14-FX
1
YAV2CL-TC14-FX-45
2
YAV2CL-TC14-FX-90
3
YAV2CL-TC38-FX
1
YAV2CL-TC38-FX-45
2
YAV2CL-TC38-FX-90
3
YAV2CL-TC516-FX
1
YAV2CL-TC516-FX-45
2
YAV2CL-TC516-FX-90
3
YAV1CL-TC10-FX
1
YAV1CL-TC10-FX-45
2
YAV1CL-TC10-FX-90
3
YAV1CL-TC12-FX
3
YAV1CL-TC12-FX-45
2
YAV1CL-TC12-FX-90
3
YAV1CL-TC14-FX
2
YAV1CL-TC14-FX-45
3
YAV1CL-TC14-FX-90
3
YAV1CL-TC38-FX
1
YAV1CL-TC38-FX-45
2
YAV1CL-TC38-FX-90
3
YAV1CL-TC516-FX
1
YAV1CL-TC516-FX-45
2
YAV1CL-TC516-FX-90
3
AWG
61/24
#6 WELD
#6 AWG
***
MM
2
**
16
Stud
Hole
Size
3/4
Tongue
Width
1.05
Figure
Dimensions
(B)
(T)
(L)
2.30
.50
.13
2.39
1.78
1.32
.50
.09
1.30
.79
1.92
.50
.07
1.84
1.34
1.44
.50
.09
1.43
.92
1.67
.50
.08
1.63
1.10
1.51
.50
.09
1.49
.98
1.50
.63
.10
1.46
.84
2.12
.63
0.09 2.03
1.40
1.62
.63
.10
1.58
.97
1.81
.63
.10
1.77
1.15
1.69
.63
.10
1.65
1.03
1.59
.69
.12
1.56
.88
2.15
.69
.12
2.12
144
1.71
.69
.12
1.69
1.00
1.90
.69
.12
1.87
1.19
1.78
.69
.12
1.75
1.07
Dieless
(# of crimps)
B
B
T
L
T
45°
L
T
B
90°
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
U5CRT (1)
Blue
7
1/2
Y2MR (1)
MY29-11 (1) W5CVT (1) X5CRT (1)
Y644M (1)
C-23
10-8
.55
91/24
105/24
-
#4 WELD
#4 AWG
1/2
.71
1/4
.55
W4CVT (1) W4CVT (1)
W4CRT (1) W4CRT (1)
X4CRT (1) X4CRT (1)
U4CRT (1)
Gray
8
1/2
3/8
.58
5/16
.55
# 10
.68
Y1MR (2)
Y2MR (2)
MY29-11 (1)
Y644M (1)
125/24
150/24
35
#2 WELD
#2 AWG
1/2
.77
1/4
.68
W2CVT (1) W2CVT (1)
W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)
U2CRT (1)
Brown
10
11/16
3/8
.68
5/16
.68
# 10
.75
175/24
225/24
-
#1 WELD
#1 AWG
1/2
.75
1/4
.75
W1CVT (1) W1CVT (1)
MY29-11 (1)
W1CRT-1 (1) W1CRT-1 (1)
Y644M (1)
X1CRT-1 (1) X1CRT-1 (1)
U1CRT (1)
Green
11
11/16
3/8
.75
5/16
.75
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™
** The 16 MM
2
is for both Class 2 and Class 5 conductors.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
FLEX CONDUCTOR
STANDARD BARREL
(CONTINUED)
Conductor
Catalog Number
Fig #
AWG
C-24
YAV25L-TC12-FX
1
YAV25L-TC12-FX-45
2
YAV25L-TC12-FX-90
3
YAV25L-TC14-FX
1
275/24
YAV25L-TC14-FX-45
2
YAV25L-TC14-FX-90
3
1/0 WELD
YAV25L-TC38-FX
1
YAV25L-TC38-FX-45
2
1/0 AWG
YAV25L-TC38-FX-90
3
YAV25L-TC516-FX
1
YAV25L-TC516-FX-45
2
YAV25L-TC516-FX-90
3
YAV26L-TC10-FX
1
YAV26L-TC10-FX-45
2
YAV26L-TC10-FX-90
3
YAV26L-TC12-FX
1
YAV26L-TC12-FX-45
2
YAV26L-TC12-FX-90
3
YAV26L-TC14-FX
1
YAV26L-TC14-FX-45
2
YAV26L-TC14-FX-90
3
325/24
YAV26L-TC34-FX
1
YAV26L-TC34-FX-45
2 2/0 WELD
YAV26L-TC34-FX-90
3
YAV26L-TC38-FX
1
2/0 AWG
YAV26L-TC38-FX-45
2
YAV26L-TC38-FX-90
3
YAV26L-TC516-FX
1
YAV26L-TC516-FX-45
2
YAV26L-TC516-FX-90
3
YAV26L-TC58-FX
1
YAV26L-TC58-FX-45
1
YAV26L-TC58-FX-90
1
YAV27L-TC10-FX
1
YAV27L-TC10-FX-45
2
YAV27L-TC10-FX-90
3
YAV27L-TC12-FX
1
YAV27L-TC12-FX-45
2
YAV27L-TC12-FX-90
3
450/24
YAV27L-TC14-FX
1
YAV27L-TC14-FX-45
2 3/0 WELD
YAV27L-TC14-FX-90
3
YAV27L-TC38-FX
1
3/0 AWG
YAV27L-TC38-FX-45
2
YAV27L-TC38-FX-90
3
YAV27L-TC516-FX
1
YAV27L-TC516-FX-45
2
YAV27L-TC516-FX-90
3
***
MM
2
Stud
Hole
Size
1/2
Tongue
Width
.83
Figure
Dimensions
(B)
(T)
(L)
2.19
.69
.12
2.15
1.47
1.75
.69
.12
1.71
1.03
1.94
.69
.12
1.90
1.22
1.81
.69
.12
1.77
1.09
1.80
.81
.13
1.73
.94
2.36
.81
.13
2.29
1.51
1.92
.81
.13
1.85
1.07
2.89
.81
.11
2.75
1.93
2.11
.81
.13
2.04
1.26
1.98
.81
.13
1.92
1.13
2.61
.81
.13
2.54
1.76
2.03
1.00
.14
1.91
.98
2.59
1.00
.14
2.47
1.54
2.15
1.00
.14
2.04
1.10
2.34
1.00
.14
2.22
1.29
2.21
1.00
.14
2.10
1.17
Dieless
(# of crimps)
B
B
T
L
T
45°
L
T
B
90°
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
1/4
50
3/8
.83
W25VT (2) W25VT (2)
W25RT (2) W25RT (2)
X25RT (2) X25RT (2)
U25RT (1)
Pink
12
11/16
.83
5/16
.83
# 10
.93
1/2
.93
1/4
.93
70
3/4
1.10
W26VT (2) W26VT (2)
W26RT (2) W26RT (2)
MY29-11 (1) X26RT (2) X26RT (2)
Y644M (1)
U26RT (1)
Black
13
13/16
3/8
.93
5/16
.93
5/8
.93
# 10
1.03
1/2
1.03
95
1/4
1.03
W27VT (2) W27VT (2)
W27RT (2) W27RT (2)
X27RT (3) X27RT (3)
U27RT (1)
Orange 14
1
3/8
1.03
5/16
1.03
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
FLEX CONDUCTOR
STANDARD BARREL
(CONTINUED)
Conductor
Catalog Number
Fig #
YAV28L-TC12-FX
1
YAV28L-TC12-FX-45
2
YAV28L-TC12-FX-90
3
YAV28L-TC14-FX
1
YAV28L-TC14-FX-45
2
YAV28L-TC14-FX-90
3
YAV28L-TC34-FX
1
YAV28L-TC34-FX-45
2
YAV28L-TC34-FX-90
3
YAV28L-TC38-FX
1
YAV28L-TC38-FX-45
2
YAV28L-TC38-FX-90
3
YAV28L-TC516-FX
2
YAV28L-TC516-FX-45
2
YAV28L-TC516-FX-90
3
YAV28L-TC58-FX
1
YAV28L-TC58-FX-45
2
YAV28L-TC58-FX-90
3
YAV29L-TC12-FX
1
YAV29L-TC12-FX-45
2
YAV29L-TC12-FX-90
3
YAV29L-TC14-FX
1
YAV29L-TC14-FX-45
2
YAV29L-TC14-FX-90
3
YAV29L-TC34-FX
1
YAV29L-TC34-FX-45
2
YAV29L-TC34-FX-90
3
YAV29L-TC38-FX
1
YAV29L-TC38-FX-45
2
YAV29L-TC38-FX-90
3
YAV29L-TC516-FX
2
YAV29L-TC516-FX-45
2
YAV29L-TC516-FX-90
3
YAV29L-TC58-FX
1
YAV29L-TC58-FX-45
2
YAV29L-TC58-FX-90
3
YA30L-TC516-FX
1
YA30L-TC516-FX-45
2
YA30L-TC516-FX-90
3
YA30L-TC38-FX
1
YA30L-TC38-FX-45
2
YA30L-TC38-FX-90
3
YA30L-TC12-FX
1
YA30L-TC12-FX-45
2
YA30L-TC12-FX-90
3
YA30L-TC58-FX
1
YA30L-TC58-FX-45
2
YA30L-TC58-FX-90
3
AWG
***
MM
2
Stud
Hole
Size
1/2
Tongue
Width
1.14
Figure
Dimensions
(B)
(T)
(L)
2.67
1.03
0.15
254
1.58
2.23
1.03
.15
2.11
1.14
3.11
1.03
.15
2.98
2.02
2.42
1.03
.15
2.29
1.33
2.29
1.03
.15
2.17
1.21
2.92
1.03
.15
2.79
1.83
2.67
1.03
.16
254
1.58
2.23
1.03
.16
2.11
1.14
3.11
1.03
.16
2.98
2.02
2.42
1.03
.16
2.29
1.33
2.29
1.03
.16
2.17
1.21
2.92
1.03
.16
2.79
1.83
2.31
1.03
.16
2.22
1.24
2.44
1.03
.16
2.35
1.36
2.69
1.03
.16
2.60
1.61
2.94
1.03
.16
2.85
1.86
Dieless
(# of crimps)
B
B
T
L
T
45°
L
T
B
90°
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
C-25
1/4
550/24
4/0 WELD
4/0 AWG
**
120
3/8
1.14
3/4
1.14
1.14
W28VT (2) W28VT (2)
MY29-11 (1)
W28RT (2) W28RT (2)
Y644M (1)
X28RT (2) X28RT (3)
U28RT (1)
Purple 15 1-1/16
5/16
1.14
5/8
1.14
1/2
1.14
1/4
1.14
550/24
-
4/0 WELD
3/4
1.14
3/8
1.14
5/16
1.14
Y644M (1)
W29VT (2)
X29RT (4)
5/8
1.14
W29VT (2)
W29RT (2)
X29RT (4)
U29RT (1)
Yellow
16 1-1/16
5/16
250 FLEX
CLASS G
259 STR.
CLASS H
427 STR.
5/8
3/8
-
1/2
1.20
1.20
1.20
1.20
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™
** The 120 MM
2
referenced here is for both Class 2 and Class 5.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
FLEX CONDUCTOR
STANDARD BARREL
(CONTINUED)
Conductor
Catalog Number
YA30L-TC34-FX
YA30L-TC34-FX-45
YA30L-TC34-FX-90
YA31L-TC14-FX
YA31L-TC14-FX-45
YA31L-TC14-FX-90
YA31L-TC516-FX
YA31L-TC516-FX-45
YA31L-TC516-FX-90
YA31L-TC38-FX
YA31L-TC38-FX-45
YA31L-TC38-FX-90
YA31L-NT12-FX
YA31L-NT12-FX-45
YA31L-NT12-FX-90
YA31L-TC12-FX
YA31L-TC12-FX-45
YA31L-TC12-FX-90
YA31L-TC58-FX
YA31L-TC58-FX-45
YA31L-TC58-FX-90
YA31L-TC34-FX
YA31L-TC34-FX-45
YA31L-TC34-FX-90
YA32L-TC38-FX
YA32L-TC38-FX-45
YA32L-TC38-FX-90
YA32L-TC12-FX
YA32L-TC12-FX-45
YA32L-TC12-FX-90
YA32L-TC58-FX
YA32L-TC58-FX-45
YA32L-TC58-FX-90
YA34L-TC516-FX
YA34L-TC516-FX-45
YA34L-TC516-FX-90
YA34L-TC38-FX
YA34L-TC38-FX-45
YA34L-TC38-FX-90
YA34L-TC12-FX
YA34L-TC12-FX-45
YA34L-TC12-FX-90
YA34L-TC58-FX
YA34L-TC58-FX-45
YA34L-TC58-FX-90
YA36L-TC12-FX
YA36L-TC12-FX-45
YA36L-TC12-FX-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
250 FLEX
CLASS G 259 STR.
CLASS H 427 STR
***
MM
2
-
Stud
Hole
Size
3/4
Tongue
Width
1.20
Figure
Dimensions
(B)
(T)
(L)
3.12
1.03
.16
3.04
2.05
2.31
1.06
.18
2.23
1.19
2.37
1.06
.18
2.30
1.27
2.50
1.06
.18
2.42
1.40
2.75
1.06
.18
2.67
1.65
2.75
1.06
.18
2.67
1.65
3.00
1.06
.18
2.92
1.90
3.19
1.06
.18
3.11
2.09
2.68
1.19
.19
2.58
1.45
2.93
1.19
.19
2.83
1.70
3.18
1.19
.19
3.08
1.95
2.74
1.27
.23
2.68
1.41
2.87
1.27
.23
2.80
1.53
3.12
1.27
.23
3.05
1.78
3.37
1.27
.23
3.30
2.03
3.29
1.38
.27
3.26
1.86
Dieless
(# of crimps)
B
B
T
L
T
45°
L
T
B
90°
L
Fig. 1
Fig. 2
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
X29RT (4)
W29VT (2)
U29RT (1)
Yellow 16 1-1/16
W29RT (2)
C-26
Mechanical
MD6, OUR840
MD7-34R
W29VT (2)
X29RT (4)
1/4
1.29
5/16
1.29
3/8
250 FLEX
637/24
CLASS I, K, M
1/2
150
1/2
1.29
.96
W30VT (2)
W30VT (2)
W30RT (2)
U30RT (2)
White
17
1-1/8
1.29
5/8
1.29
3/4
1.29
Y644M (1)
3/8
313.1 KCMIL
775/24
300 FLEX
5/8
185
1/2
1.40
1.40
W31VT (2)
W31VT (2)
W31RT (2)
U31RT (2)
Red
18
1-1/4
1.40
5/16
373.7 KCMIL
925/24
350 FLEX
240
1/2
1.55
3/8
1.55
W32VT (2)
W32VT (2)
W32RT (2)
U32RT (2)
Blue
19 1-5/16
1.55
5/8
444.4 KCMIL
450 FLEX
1.55
-
1/2
1.74
-
-
U34RT (2)
Brown 20
1-3/8
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
查看更多>
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消